Datasheet

Model/Valve Specifications
N.C.
Passage symbol
N.O.
Passage symbol
Normally Closed (N.C.)
Normally Open (N.O.)
Port size
Size
Orifice diameter
[mmø]
Model
Maximum operating
pressure differential
[MPa]
0.9
0.45
0.2
0.8
0.15
0.8
0.3
320
320
320
490
490
620
620
2
3
5
4
7
5
8
1/8, 1/4
1/4, 3/8
1/4, 3/8
1
2
3
AV (x 10
−6
m
2
)
0.23
0.42
0.63
0.63
1.08
0.75
1.58
5.5
10.0
15.0
15.0
26.0
18.0
38.0
Conversion Cv
Flow-rate characteristics
VX245
VX255
VX265
Weight
[g]
Note) Weight of grommet type. Add 10 g for conduit type, 60 g for conduit terminal type respectively.
Port size
Size
Orifice diameter
[mmø]
Model
Maximum operating
pressure differential
[MPa]
1
0.6
0.2
1
0.15
1
0.3
0.1
0.1
2
3
5
4
7
5
8
10
10
1/8, 1/4
1/4, 3/8
1/4, 3/8
1/2
1
2
3
AV (x 10
−6
m
2
)
0.23
0.42
0.63
0.63
1.08
0.75
1.58
2.21
2.21
Conversion Cv
Flow-rate characteristics
VX215
VX225
VX235
Weight
[g]
5.5
10.0
15.0
15.0
26.0
18.0
38.0
53.0
53.0
300
300
300
460
460
580
580
580
630
Fluid and Ambient Temperature Valve Leakage
FKM for high temperature
Seal materialFluid Leakage rate
1.0 cm
3
/min or less
0.1 cm
3
/min or less
FKM for high temperature
Steam
Heated water
Steam
Heated water
Seal materialFluid
Leakage rate
1.0 cm
3
/min or less
0.1 cm
3
/min or less
Ambient temperature [°C]
−20 to 60
Fluid temperature [°C]
Steam: 183 or less
Heated water: 99 or less
Internal Leakage
External Leakage
21
21
Can be used with heated water.
Refer to “Glossary of Terms” on page 29 for passage symbols.
Note)
Note)
Single UnitFor Steam
Series VX21/22/23
18