Datasheet
Manual override
qq
ww
ee
r
r
t
y
u
( )
2
1
12
Ground
A 2
( )
A 2
( )
R
1
1
1
1
2
2
2
2
3
3
3
3
3
( )
R3
( )
P1
( )
P1
Voltage
100 VAC
200 VAC
DC
Others
Colour
Blue
Red
Red (+), Black (–)
Grey
Terminal no.
DIN terminal
12
+−
Description
DIN connector
Part no.
GM209NJ-B17
Connector for DIN Terminal
How to Use DIN Terminal
1. Disassembly
1)
After loosening the screw 
q
, then if the 
housing 
w
 is pulled in the direction of the 
screw 
q
, the connector will be removed from 
the body of equipment (solenoid, etc.).
2)
Pull the screw 
q
 out of the housing 
w
.
3)
On the bottom part of the terminal block 
e
, 
there’s a cut-off part 
o
. If a small flat head 
screwdriver is inserted between the opening 
in the bottom, terminal block 
e
 will be 
removed from the housing 
w
. 
4)
Remove the cable gland 
r
, plain washer 
t
and rubber seal 
y
.
2. Wiring
1)
Pass the cable 
u
 through the cable gland 
r
, 
plain washer 
t
 and rubber seal 
y
 in this order, 
and then insert them into the housing 
w
.
2)
Loosen the screw 
!
1 attached to the terminal 
block 
e
. Then, pass the lead wire 
!
0 through the 
terminal block 
e
 and tighten the screw 
!
1 again.
Note 1) Tighten within the tightening torque of 
0.5 N·m ±15%.
Note 2) Cable 
u
 outside diameter: ø6 to ø8 mm
Note 3) Crimped terminal like round-shape or 
Y-shape cannot be used.
3. Assembly 
1) Pass the cable 
u
 through the cable gland 
r
, 
plain washer 
t
 and rubber seal 
y
 in this order 
and connect to the terminal block 
e
. Then, mount 
the terminal block 
e
 on the housing 
w
.
(Push it down until you hear the click sound.)
2) Put the rubber seal 
y
 and plain washer 
t
 in this 
order into the cable entry of the housing 
w
, and 
then tighten the cable gland 
r
 securely.
3) Insert the gasket 
i
 between the bottom part of 
terminal block 
e
 and the plug attached to the 
equipment. Then, screw in 
q
 from the top of the 
housing 
w
 to tighten it. 
Note 1) Tighten within the tightening torque of 0.5 
N·m ±20%.
Note 2) Connector orientation can be changed  
180° depending on how the housing 
w
and the terminal block 
e
 are assembled.
De-energized Energized
Light/Surge Voltage Suppressor
Caution
Electrical Connection
Lead Wire Colour
DIN terminal is connected inside as in the 
figure below. Connect to the corresponding 
power supply.
DIN terminal block
· Applicable cable O.D.
ø6 to ø8
Construction
Terminal no. 2
Coil
Terminal no. 1
Terminal no. 2 (–)
Coil
Terminal no. 1 (+)
In the case of indicator
light assembly
In the case of indicator
light assembly
!0
q
e
r
t
y
u
i
o
!1
w
1
2
3
4
No.
MaterialDescription
Aluminium die-casted
Aluminium, HNBR
Stainless steel
Body
Poppet valve
Return spring
Molded coil
Resin
Note
Colour: White
Operation principle
<De-energized>
Poppet valve w is pushed upward by the return 
spring e, port   is closed. Then, port and port
 are connected.
Air flow direction:
Port 
←→
 Block,   
←→
<Energized>
When energizing the molded coil r, the arma-
ture  t is magnetically attracted to the core y, 
and through the push rod u, it pushes down the 
poppet valve w and port is closed. Then, port
 and port   are connected. At this time, there 
will be gaps between the armature t and the 
core y, but the armature t will be magnetically 
firmly attracted to the core y.
Air flow direction:
Port 
←→ 
Port  , Port 
←→ 
Block
Component Parts
AC
DC
Series VT307
3 Port Solenoid Valve
Direct Operated Poppet Type
3










