Datasheet

Note 1) Based on dynamic performance test, JIS B 8374-1981. (Coil temperature: 20°C, at rated voltage,
without surge voltage suppressor)
Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction
and at the right angles to the main valve and armature in both energized and
de-energized states every once for each condition. (Values at the initial period)
Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 1000 Hz. Test
was performed at both energized and de-energized states in the axial direction
and at the right angles to the main valve and armature. (Values at the initial
period)
Note 3) At rated voltage
Note 4)
The value is different for continuous duty type (VT307E), and energy-saving type (VT307Y/W)
.
Refer to “Valve Options” shown below.
Make sure that dust and/or other foreign
materials do not enter the valve from the
unused port (e.g. exhaust port).
Caution
Continuous duty type: VT307E
Exclusive use of VT307E is recommended
for continuous duty with long time loading.
Energy-saving type: VT307Y (VT307W)
If low power consumption is required for
electronic control, “VT307Y(W)” (1.8 W) is
recommended.
Vacuum spec. type: VT307V (VT307W)
This vacuum model has less air leakage than
the standard model under low pressure. It is
recommended for vacuum application.
1. This model is for continuous duty, not for
high cycle rates. But even in low cycle
rates, if energizing the valve more than
once a day, please consult with SMC.
2. Energizing solenoid should be done at
least once in 30 days.
Caution
Since this valve has slight air leakage, it can
not be used for vacuum holding (including
positive pressure holding) in the pressure
container.
Caution
Note) Refer to Note 1) of the standard specifications.
Specifications different from standard are as follows.
Note) Refer to Note 1) of the standard specifications.
Operating pressure range
–101.2 kPa to 0.1 MPa
Specifications different from standard are as follows.
Type of actuation
Fluid
Operating pressure range
Ambient and fluid temperature
Response time
Note 1)
Max. operating frequency
Lubrication
Manual override
Mounting orientation
Impact/Vibration resistance
Note 2)
Enclosure
Direct operated type 2 position single solenoid
Air
0 to 1 MPa (High-pressure type), 0 to 0.7 MPa (Standard type)
–10 to 50°C (No freezing)
20 ms or less (at 0.5 MPa)
10 Hz
Not required (Use turbine oil Class 1 ISO VG32, if lubricated.)
Non-locking push type
Unrestricted
150/50 m/s
2
Dustproof
Electrical entry
Coil rated voltage [V]
Allowable voltage fluctuation
Apparent power
Note 3) Note 4)
AC
DC
AC
DC
DC
AC (50/60 Hz)
Inrush
Holding
DIN terminal
24, 48, 100, 110, 200, 220, 240
6, 12, 24, 32, 48, 100
–15 to +10% of rated voltage
12.7 VA (50 Hz), 10.7 VA (60 Hz)
7.6 VA (50 Hz), 5.4 VA (60 Hz)
Without indicator light: 4 W, With indicator light: 4.2 W
Varistor, LED
Diode, LED
Power consumption
Note 3) Note 4)
Light/Surge voltage suppressor
C[dm
3
/(s·bar)]
bCv
Port
size
1/8
1/4
Valve model
VT307
VT307V
(Vacuum spec. type)
VT307E (Continuous duty type)
VT307Y (Energy-saving type)
VT307W
(Energy-saving, Vacuum spec. type)
VT307
VT307V
(Vacuum spec. type)
VT307E (Continuous duty type)
VT307Y (Energy-saving type)
VT307W
(Energy-saving, Vacuum spec. type)
C[dm
3
/(s·bar)]
bCv
C[dm
3
/(s·bar)]
bCv
C[dm
3
/(s·bar)]
bCv
0.71
0.41
0.71
0.49
0.35
0.26
0.31
0.20
0.18
0.10
0.19
0.12
0.68
0.44
0.71
0.44
0.27
0.35
0.25
0.34
0.17
0.11
0.17
0.11
0.65
0.48
0.68
0.48
0.36
0.27
0.33
0.17
0.17
0.12
0.17
0.12
0.63
0.35
0.71
0.46
Q [L/min]
(ANR)
Note 2)
187
102
182
117
Q [L/min]
(ANR)
Note 2)
170
116
175
115
Q [L/min]
(ANR)
Note 2)
172
120
176
113
Q [L/min]
(ANR)
Note 2)
166
91
176
116
0.35
0.33
0.26
0.28
0.17
0.10
0.18
0.11
Flow-rate characteristics
1
2 (P
A) 2
3 (A
R) 3
2 (R
A) 2
1 (A
P)
Apparent power/
AC
Inrush
Holding
7.9 VA (50 Hz), 6.2 VA (60 Hz)
5.8 VA (50 Hz), 3.5 VA (60 Hz)
Power consumption/DC
1.8 W, With indicator light: 2 W
30 ms or less (at 0.5 MPa)
Response time
Note)
Specifications different from standard are as follows.
1.8 W, With indicator light: 2 W
25 ms or less (at 0.5 MPa)
Power consumption/DC
Response time
Note)
Valve Options
Standard Specifications
Flow-rate Characteristics
Series VT307
Note 1) Values for a single valve unit. It is not applicable to the manifold. Refer to the manifold specifications on page 5.
Note 2) These valves have been calculated according to ISO6358 and indicate the flow rate under standard conditions with an inlet pressure of 0.6 MPa (relative
pressure) and a pressure drop of 0.1 MPa.
2