Datasheet
Function plate
Figure: For N.C.
Function plate
No mark
NO
Specifications
N.C.
N.O.
Port positions for manifold
solenoid valve body
Port c
Port x
Port z
Mounting
Piping
Warning
Caution
When mounting a valve on the manifold base, N.C. and N.O. can
be reversed by the function plate orientation. Also, since the
cylinder operates in reverse, confirm if the function plate is
correctly mounted or not.
Changing from N.C. to N.O.
Caution
Caution
Function plate
N.O.
specification
N.C.
specification
1. Each valve is fixed to the manifold base with two M4 mounting
screws. Tighten the screws firmly when re-mounting.
2. For mounting, tighten M4 or equivalent screws evenly into the
mounting holes of the manifold base.
Tightening torque of the mounting screw (M4): 1.4 N·m
1. For the common exhaust type, pressurisation or evacuation of
the 3(R) port can cause a malfunction.
This product is delivered as N.C. valve.
If N.O. valve is required, remove mounting screws of the required
valve and turn over the function plate. (Make sure that there are
gaskets on both sides of the plate.) Then, tighten the mounting
screws to fix the valve to the manifold base.
Series VT307
Specific Product Precautions
Be sure to read before handling. Refer to back cover for Safety Instructions and “Handling
Precautions for SMC Products” (M-E03-3) for 3/4/5 Port Solenoid Valve Precautions.
8