Datasheet
Standard Specifications
Characteristic Specifications
VDW200
VDW300
Model
ø1
ø1.6
ø2
ø3
ø4
0.9
0.7
0.8
0.4
0.2
0.54 (0.03)
1.2 (0.07)
2.8 (0.16)
5.0 (0.28)
8.0 (0.44)
0.3
0.1
0.2
0.1
0.05
Orifice
size
mm
Weight
kg
Port size
M5
1/8 (6A)
1/8 (6A)
1/4 (8A)
0.12
0 to 1.0
1/8: 0.27
1/4: 0.30
Note 2)
Note 1) Effective area is for the case when IN is normally closed (N.C.).
Note 2) Indicates the maximum operating pressure differential of pressure ports 2 and 3.
Note 3) The maximum operating pressure differential changes depending on the flow direction of the fluid.
Refer to page 21 for details.
Note 4) For low vacuum specifications, the operating pressure range is 1Torr (1.33 x 10
²Pa) to 1.0MPa.
Consult SMC if used below 1Torr (1.33 x 10
²Pa).
Valve specifications
Coil
specifications
Valve construction
Fluid
Note 2)
Withstand pressure MPa
Ambient temperature °C
Fluid temperature °C
Environment
Valve leakage cm
3
/min
Mounting orientation
Vibration/Impact m/s
2
Note 4)
Rated voltage
Allowable voltage fluctuation %
Coil insulation type
Enclosure
Note 5)
Power consumption W
Note 3)
Maximum operating
pressure
differential MPa
Note 3)
Effective area
mm²
(Cv factor)
Note 1)
Operating
pressure
range
MPa
Note 4)
Pressure port 1
Pressure ports 2, 3
Direct operated poppet
Water (except waste water or agricultural water), Air, Low vacuum
2.0
–10 to 50
1 to 50 (with no freezing)
Location without corrosive or explosive gases
0 (with water pressure)
Unrestricted
30/150
24VDC, 12VDC, 100VAC, 110VAC, 200VAC, 220VAC (50/60Hz)
±10% of rated voltage
Class B
Dust proof (equivalent to IP40)
3
Note 1) Consult SMC when used under conditions which may cause condensation on the exterior of the product.
Note 2) When used with pure water, select "L" (stainless steel, FKM) for the material type.
Note 3) Since AC coil specifications include a rectifying device, there is no difference in power consumption for starting
and holding.
3.5W in case of 110/220VAC.
Note 4) Vibration resistance …No malfunction when tested with one sweep of 5 to 200Hz in the axial direction and at a
right angle to the armature, in both energized and deenergized states.
Impact resistance ….. No malfunction when tested with a drop tester in the axial direction and at a right angle to
the armature, one time each in energized and deenergized states.
Note 5) Consult SMC regarding drip-proof specifications (equivalent to IP54) .
Series
VDW200/300
12