Specifications

CLI Management Guide
TigerAccess™ EE
92 SMC7824M/VSW
time from beginning of the 15 minutes and time of error (Prev. 15m) of previous 15 min-
utes. Also, you can check times of error (Today) at present time from starting Today, times
of error (Yesterday) of yesterday, and total times of error from booting. The following im-
age shows standard of error counting provided in switch.
Fig. 5.4 Counting Times of Error
To display the number of errors in VDSL port, use the following command.
Command Mode Description
show lre stat-correctable-crc PORTS
Shows the numbers of CRC errors that
can be correctable.
show lre stat-lof PORTS Shows the numbers of Frame loss.
show lre stat-los PORTS Shows the numbers of Signal loss.
show lre stat-lol PORTS Shows the numbers of Link loss.
show lre stat-lpr PORTS Shows the numbers of CPE's Power loss
show lre stat-crc PORTS Shows the numbers of CRC errors
show lre stat-uncorrectable-crc PORTS
Enable
Global
Bridge
Shows the numbers of CRC errors that
can be uncorrectable.
To reset data of CRC error, Frame loss and Signal loss, use the following command.
Command Mode Description
clear lre stat-correctable-crc PORTS
clear lre stat-lof PORTS
clear lre stat-los PORTS
clear lre stat-lol PORTS
clear lre stat-lpr PORTS
clear lre stat-crc PORTS
clear lre stat-uncorrectable-crc PORTS
Enable
Global
Bridge
Resets data of error.