Specifications

CLI Management Guide
TigerAccess™ EE
80 SMC7824M/VSW
To control supplied power according to VDSL line, use the following command.
Command Mode Description
lre PORTS upbo enable Bridge
Controls supplied power according to distance of VDSL
line.
You should control supplied power of VDSL port according to distance of VDSL line.
To disable power control according to distance of VDSL line, use the following command.
Command Mode Description
lre PORTS upbo disable Bridge
Disables power control according to distance of VDSL
line.
The following is an example of disabling power control according to distance of VDSL line.
SWITCH(bridge)# lre 1-3 upbo disable
SWITCH(bridge)# show lre psd 1-5
-----------------------------------------------------------
Port Status Up Stream PBO Length PSD MASK
ADM/OPR PBO (10 Custom) Level
---------------------
| u 0 | u1 | u2 | u3 |
-----------------------------------------------------------
1 Up/Up disable | 2 | 2 | 2 | 2 | 11
2 Up/Up disable | 2 | 2 | 2 | 2 | 11
3 Up/Down disable | 2 | 2 | 2 | 2 | 11
4 Up/Down Enable | 2 | 2 | 2 | 2 | 11
5 Up/Down Enable | 2 | 2 | 2 | 2 | 11
SWITCH(bridge)#
If you control power according to VDSL line, it is applied to all ports.
You cannot configure power consumption supplied to VDSL line with power control ac-
cording to the distance of line enabled. In this case, the standard to decide power con-
sumption is the distance.
To configure power consumption supplied to VDSL line, use the following command.
Command Mode Description
lre PORTS pbo-length {123
45678910}
Bridge
Configures power consumption supplied to VDSL line
according to the distance.
The default is “2”.
i
!
i