Specifications
CLI Management Guide
TigerAccess™ EE
146 SMC7824M/VSW
7.1.9.5 ADVA Alarm Severity
To set ADVA alarm severity, use the following command.
Command Mode Description
snmp alarm-severity adva-fan-fail {critical |
major | minor | warning | intermediate}
Sets ADVA severity of an alarm for sys-
tem temperature high.
snmp alarm-severity adva-if-misconfig {critical
| major | minor | warning | intermediate}
Sets ADVA severity of an alarm for
wrong configuration.
snmp alarm-severity adva-if-opt-thres {critical |
major | minor | warning | intermediate}
Sets ADVA severity of an alarm for traf-
fic threshold over for an Ethernet optical
interface.
snmp alarm-severity adva-if-rcv-fail {critical |
major | minor | warning | intermediate}
Sets ADVA severity of an alarm for fail-
ure to receive packets.
snmp alarm-severity adva-if-trans-fault {criti-
cal | major | minor | warning | intermediate}
Sets ADVA severity of an alarm for fail-
ure to transmit packets.
snmp alarm-severity adva-if-sfp-mismatch
{critical | major | minor | warning | intermedi-
ate}
Sets ADVA severity of an alarm for SFP
module mismatched.
snmp alarm-severity adva-psu-fail {critical |
major | minor | warning | intermediate}
Sets ADVA severity of an alarm for PSU
failure.
snmp alarm-severity adva-temperature {critical
| major | minor | warning | intermediate}
Sets ADVA severity of an alarm for sys-
tem temperature high.
snmp alarm-severity adva-voltage-high {criti-
cal | major | minor | warning | intermediate}
Sets ADVA severity of an alarm for input
voltage high.
snmp alarm-severity adva-voltage-low {critical
| major | minor | warning | intermediate}
Global
Sets ADVA severity of an alarm for input
voltage low.
To delete configured ADVA alarm severity, use the following command.
Command Mode Description
no snmp alarm-severity adva-fan-fail
no snmp alarm-severity adva-if-misconfig
no snmp alarm-severity adva-if-opt-thres
no snmp alarm-severity adva-if-rcv-fail
no snmp alarm-severity adva-if-sfp-mismatch
no snmp alarm-severity adva-if-trans-fault
no snmp alarm-severity adva-psu-fail
no snmp alarm-severity adva-temperature
no snmp alarm-severity adva-voltage-high
no snmp alarm-severity adva-voltage-low
Global
Deletes configured ADVA alarm sever-
ity.