Specifications
CLI Management Guide
TigerAccess™ EE
120 SMC7824M/VSW
When you set the threshold of fan operation, START-TEMP must be higher than STOP-
TEMP.
To show the configured threshold of fan operation, use the following command.
Command Mode Description
show status fan Enable/Global/Bridge
Shows the status and configured thresh-
old of fan operation.
6.1.13.4 System Temperature
To set the threshold of system temperature, use the following command.
Command Mode Description
threshold temp <-40-100>
Sets the threshold of system temperature in the unit of
centigrade (°C).
-40-100: system temperature (default: 80)
no threshold temp
Global
Deletes a configured threshold of system temperature.
To show the configured threshold of system temperature, use the following command.
Command Mode Description
show status temp
Enable
Global
Bridge
Shows the status and configured threshold of system
temperature.
6.1.13.5 System Memory
To set the threshold of system memory in use, use the following command.
Command Mode Description
threshold memory <20-100>
Sets the threshold of system memory in the unit of
percent (%).
20-100: system memory in use
no threshold memory
Global
Deletes the configured threshold of system memory.
!