Specifications
Management Guide CLI
TigerAccess™ EE
SMC7824M/VSW 117
6.1.9 Fan Operation
For the switch, it is possible to control fan operation. To control fan operation, use the fol-
lowing command.
Command Mode Description
fan operation {on | off} Global Configures fan operation.
It is possible to configure to start and stop fan operation according to the system tempera-
ture. To configure this, see Section
6.1.13.3.
To display fan status and the temperature for fan operation, use the following command.
Command Mode Description
show status fan
Enable
Global
Bridge
Shows the fan status and the temperature for the fan
operation.
6.1.10 Disabling Daemon Operation
You can disable the daemon operation unnecessarily occupying CPU. To disable certain
daemon operation, use the following command.
Command Mode Description
halt PID Enable Disables the daemon operation.
You can display the PID of each running processs with the show process command.
SWITCH# show process
USER PID %CPU %MEM VSZ RSS TTY STAT START TIME COMMAND
admin 1 0.2 0.2 1448 592 ? S Feb23 0:05 init [3]
admin 2 0.0 0.0 0 0 ? S Feb23 0:00 [keventd]
admin 3 0.0 0.0 0 0 ? SN Feb23 0:00 [ksoftirqd_CPU0]
admin 4 0.0 0.0 0 0 ? S Feb23 0:00 [kswapd]
admin 5 0.0 0.0 0 0 ? S Feb23 0:00 [bdflush]
admin 6 0.0 0.0 0 0 ? S Feb23 0:00 [kupdated]
admin 7 0.0 0.0 0 0 ? S Feb23 0:00 [mtdblockd]
admin 8 0.0 0.0 0 0 ? S< Feb23 0:00 [bcmDPC]
admin 9 0.0 0.0 0 0 ? S< Feb23 0:29 [bcmCNTR.0]
admin 16 0.0 0.0 0 0 ? SN Feb23 0:00 [jffs2_gcd_mtd0]
admin 81 0.0 2.0 10524 5492 ? S Feb23 0:53 /usr/sbin/swchd
admin 83 0.0 1.5 6756 3756 ? S Feb23 0:53 /usr/sbin/nsm
(Omitted)
SWITCH#
6.1.11 FTP Server
FTP server is enabled on this switch by default. But this configuration can’t provide the
security serveice becaue it’s easy to access to the port of #23 by others. If the default
i