○EX600-WDYA1
No.
Name Application
1 Area close to NFC antenna
This area is in close contact with the NFC reader / writer.
"O" is the center of the NFC antenna.
2 Status LED LED display to indicate the unit status.
3
Screw hole for mounting
(M5 x 4)
Used for installing sheet metals.
4
FG terminal
※
1
To be connected to Ground. (for better noise immunity).
5 Power supply cable Connect the power supply for control and output.
6 Output cable (E/F) Connect the output equipment (M12 connector)
7 Output cable (C/D) Connect the output equipment (M12 connector)
8 Output cable (A/B) Connect the output equipment (M12 connector)
9 Output cable (8/9) Connect the output equipment (M12 connector)
10
Output cable (6/7) Connect the output equipment (M12 connector)
11 Output cable (4/5) Connect the output equipment (M12 connector)
12
Output cable (2/3) Connect the output equipment (M12 connector)
13
Output cable (0/1) Connect the output equipment (M12 connector)
14
Pairing cable Pressed when switching to pairing mode.
15
Short jumper
Connect the jumper connector normally, and disconnect the jumper connector
when pairing.
*1: Grounding should be as close as possible to the product and the grounding wire should be as short as possible.