2. Specifications 
Port size  Rc1/4, NPT1/4, G1/4, Rc3/8, NPT3/8, G3/8 
Fluid  Air, Nitrogen, Carbon dioxide gas(gas) 
Rated flow  500L/min (ANR)
*1
Nominal filtration rating
*2
  0.01μm (99.99%)
*5
Operating pressure range
*3
-100kPa to 1.0MPa 
(For nitrogen, Carbon dioxide gas: 0.99MPa) 
Operating temperature  5 to 45
o
C 
Initial pressure drop  0.03MPa(Inlet pressure 0.7MPa, at max. flow rate) 
Element proof differential pressure
*4
  0.5MPa 
Proof pressure  1.5MPa 
Element life  1 year, or when the pressure drop reaches 0.1 MPa 
Materials 
of parts in 
contact 
with fluid 
Metal parts  Stainless steel 
Resin/Rubber parts 
Materials compliant with FDA/Food Sanitation Law 
Weight 
Port size 1/4  450g 
Port size 3/8  430g 
*1 Maximum flow rate at inlet pressure 0.7 MPa and pressure drop 0.03 MPa. 
*2 Measured under SMC’s specified conditions. 
*3 The maximum operating pressure varies depending on temperature. 
*4 This means that the element does not break at 0.5 MPa. 
*5 The bacteria removal filter is intended to filter solid particles. It is not suitable for the separation 
of water and oil. 
Bacteria removal performance (bacteria capture performance of filter element) LRV ≥ 9 
LRV (Log Reduction Value) indicates the bacteria capture performance. 
LRV=Log
10
[Demonstrated by a third-party research institution (Test reference report No.: 2019D-BT-548)] 
* This does not guarantee that all bacteria will be removed. Not for eliminating the virus. This is 
the data evaluated based on JIS K 3835. 
A    A: Total number of test bacteria applied upstream of the filter 
B    B: Total number of test bacteria after passing through the filter (downstream) 
2022-10-1811:22
DP 097499