Brochure
Indicated value is the same at any installation
position. (No conversion is needed.)
Indicated value depends on installation position.
(Conversion is required.)
Indicated value
depends on the
viewing angle.
Mounting orientation is not limited.
Vertical
orientation
only
Can detect whether
greater or less than
set flow rate. The flow
condition can be
controlled all the time.
Can only detect when
float passes. Cannot
detect whether greater
or less than set flow
rate.
A photoelectric switch,
or similar, must be
prepared separately.
Not
displayable
Able to confirm the total air
consumption per day
(Max. 999999
l
)
Accumulated pulse output
is also equipped.
ON
OFF
Less Flow
rate
ON
OFF
Less Flow
rate
With switch output
and analogue output
Without output function
Control by sensor output
Visual control
With switch output and analogue output
Digital display
Not subject to pressure variations
Free mounting orientation
Accumulated flow display
Comparison with Float Type Flow Meter
Greater Greater
Control of metal wire tension
Suction check
• Accumulated indication shows the
operating flow rate or residual amount
(of
N2 etc.) in a gas cylinder.
The decimal point indicators flash in power-saving mode.
Selection of
indication unit
User can select between ANR and Nl/min for each fluid.
[ANR] Indicates the flow rate converted to a volume under standard conditions: 20°C, 1 atm
(atmosphere), 65%RH
[Nl/min] Indicates the flow rate converted to a volume under normal conditions: 0°C, 1 atm (atmosphere).
External input Can be selected from accumulated value external reset, auto-shift and auto-shift zero.
Indication
resolution
Minimum unit setting can be selected from 1 l/min, 0.1 l/min and 0.01 l/min. Depends on the model.
Refer to the specifications (P. 33) for details.
Clip
One-touch fitting
Flow
adjustment
valve
Female thread
The accuracy may fluctuate by 2 to 3% just after replacement.
(Repeatability does not change.)
Suction
filter
ZF PFM
Flow
switch
Vacuum line
Compressed air line
Vacuum line
Dryer
IDFA AF AR
IR
AMD
AFD
PFM
Air filter Regulator Micro mist
separator
Flow
switch
Applications
Main Functions
Several Combinations
Recommended Air Circuits
Flashing
Flashing
For details and other functions, refer to page 33.
Selection of fluid
Air, Nitrogen (N2), Argon (Ar) or Carbon dioxide
(CO2) can be selected using the buttons.
Secret code setting function
The user must input a secret code to cancel the
keylock mode. This ensures that only authorised
persons can operate the switch.
Power-saving mode
Turning off the display can save power consumption.
Detection
camera
• Flow control of
N
2
gas to
prevent lead
frame oxidation.
• N2 blow
prevents
distortion of
camera image
due to air
turbulence.
Depending on the installation conditions, it is possible to
add or remove the flow adjustment valve, change
the
fitting type
and the
piping direction
as desired.
Refer to page 27 for details.
Welder
Models compatible with argon (Ar) and
carbon dioxide (CO
2
) mixed gas are
available. Refer to page 37 for details.
Features 3