Brochure

23
11IN1 IN IN
43
52.4
43
1.2
48
18
1.2
51.5 (Max. 58.5)
18
43
48
With bracket / Without flow adjustment valve With bracket / With flow adjustment valve
DIN rail mounting
Cable Specifications of Lead Wire
with Connector
Connects to the PFM3 series.
Insulation
Finished external diameter
Nominal cross section area
Material
Construction
External diameter
Material
External diameter
Colors
Material
Color
Rated temperature
Rated voltage
Number of wires
Conductor
Sheath
80°C
30
V
4
AWG26
Soft copper wire
28 / 0.08 mm
Approx. 0.50 mm
Cross-linked vinyl chloride resin compound
Approx.
1.00 mm
Brown, White, Black, Blue
Oil-resistant vinyl chloride resin compound
Light grey
ø3.5
+0.10
–0.25
5
±2
Brown
White
Black
Blue
6.5
+21–
2020
+50
0
20
0
–5
30
±3
Terminal semi-stripped
Lead wire with connector
ZS-33-D
48
36
28
34
26
18
4 x 3.4
FLOW SENSOR
POWER FLOW
34
26
18
24 28
76
4 x 3.4
36
FLOW SENSOR
POWER FLOW
18 x n pcs. + 34.4
18
48
FLOW SENSOR
POWER FLOW
FLOW SENSOR
POWER FLOW
FLOW SENSOR
POWER FLOW
Dimensions
DIN rail (supplied by customers)
Port size, F02: G1/4 cannot be mounted on the DIN rail.
2-Colour Display Digital Flow Switch
Series PFM5
OUT
Panel thickness 1 to 3.2
42.5 3
IN
42.5 3
Panel thickness
1 to 3.2
51.5 (Max.58.5)
342.5
Panel thickness 1 to 3.2
3
Panel thickness
1 to 3.2
51.5 (Max.58.5)
76
A
42.5 3
Panel mount / Without flow adjustment valve / Straight
Panel mount / With flow adjustment valve / Straight
Panel mount / Without flow adjustment valve Panel mount / With flow adjustment valve
(mm)
One-touch fitting
Applicable tube O.D.
ø4 (5/32")
ø6
ø8 (5/16")
ø1/4
A
92.2
92.6
96
92.6
78
28
29.9
FLOW SENSOR
POWER FLOW
(mm)
One-touch fitting
Applicable tube O.D.
ø4 (5/32")
ø6
ø8 (5/16")
ø1/4
A
64.2
64.6
68
64.6
A
58
28
29.9
FLOW SENSOR
POWER FLOW
29.9
28
18
88
58
FLOW SENSOR
POWER FLOW
93
78
18
28
29.9
FLOW SENSOR
POWER FLOW
Dimensions
Note) Piping entry direction: Minimum dimensions for bottom side piping. If using
straight piping, the piping material and tubing need to be taken into
consideration when designing the system. If a bend (R) is used, limit it to R3 or
less.
Panel Fitting Dimensions
Panel thickness 1 to 3.2 mm
Note) Piping entry direction: Minimum dimensions for bottom side piping. If using
straight piping, the piping material and tubing need to be taken into
consideration when designing the system. If a bend (R) is used, limit it to R3 or
less.
Panel Fitting Dimensions
Panel thickness 1 to 3.2 mm
94 or more
Note)
74
+0.5
0
34 or more
24
+0.5
0
94 or more
Note)
54
+0.5
0
34 or more
24
+0.5
0
4 x R3 or less
4 x R3 or less
4 x R3 or less
4 x R3 or less
4 x R3 or less
4 x R3 or less
Series PFM5