Datasheet
How to Order
46
Nil
M
Unit specification
With unit switching function
Fixed SI unit
Panel mounting
0
1
NPN open collector 2 outputs
PNP open collector 2 outputs
PF2D3 A0M
Output specification
0
Note) Fixed units: Real-time flow rate: l/min
Accumulated flow:
l
Digital Flow Switch
Series PF2D
For Deionized Water and Chemicals
Remote Type
Display Unit
PF2D300/301
Specifications for Display Unit
Model
Flow rate measurement range
Note 1)
Set flow rate range
Note 1)
Minimum set unit
Note 1)
Accumulated pulse flow rate exchange
value (Pulse width: 50ms)
Note 1)
Accumulated flow range
Note)
Linearity
Note 3)
Repeatability
Temperature characteristics
Current consumption (No load)
Weight
Indicator light
Status LED’s
Power supply voltage
Response time
Hysteresis
Switch output
Accumulated pulse output
Enclosure
Operating temperature range
Voltage resistance
Insulation resistance
Vibration resistance
Impact resistance
Noise resistance
Display
units
Note 2)
Real-time flow rate
Accumulated flow
Environmental
resistance
Note 4)
Output specifications
0.25 to 4.5 l/min 1.3 to 21.0 l/min 2.5 to 45 l/min
0.25 to 4.5
l/min 1.3 to 21.0 l/min 2.5 to 45 l/min
0.05
l/min 0.1 l/min 0.5 l/min
0.05
l/pulse 0.1 l/pulse 0.5 l/pulse
l/min, gal (US)/min
l, gal (US)
0 to 999999
l
±2.5% F.S. or less
±0.5% F.S. or less
±1% F.S. or less (15 to 35°C, based on 25°C)
±2% F.S. or less (0 to 50°C, based on 25°C)
60 mA or less
45 g
Maximum load current: 80 mA
NPN open collector Internal voltage drop: 1 V or less (with load current of 80 mA)
(PF2D300) Maximum applied voltage: 30 V
2 outputs
PNP open collector
Maximum load current: 80 mA
Internal voltage drop: 1.5 V or less (with load current of 80 mA)
(PF2D301)
2 outputs
NPN open collector or PNP open collector (same as switch output)
IP40
Operating: 0 to 50°C, Stored: –25 to 85°C (with no condensation and freezing)
1000 VAC for 1 min. between external terminal and case
50M Ω or more (500 VDC Mega) between external terminal and case
10 to 500 Hz with a 1.5 mm amplitude or 98 m/s
2
acceleration in each X, Y, Z direction for 2 hrs., whichever is smaller.
490 m/s
2
to X, Y, Z directions 3 times for each
1000 Vp-p, Pulse width: 1 µs, Rise time: 1 ns
3-digits 7-segment LED
ON: when light is on, OUT1: Green; OUT2: Red
12 to 24 VDC (ripple ±10% or less)
1sec. or less
Hysteresis mode: adjustable (can be set from 0) Window comparator mode
Note 5)
: fixed (3 digits)
Note 1) The value varies depending on set flow range
Note 2) For digital flow switch with unit switching function. (Fixed SI unit [
l/min or l] will be set for switch types without the unit switching function.)
Note 3) The system accuracy when combined with PF2D5.
Note 4) Switch output and accumulated pulse output can be selected using the control button operation during initial setting.
Note 5)
Window comparator mode: Since hysteresis (H) will reach 3 digits, keep P_1 and P_2 or n_1 and n_2 apart by 7 digits more. (In case of output OUT2, n_1, 2 to be n_3, 4 and P_1, 2 to be P_3, 4.)
Note 6) The display unit conforms to the CE mark.
Note) Accumulated flow rate is reset when the power supply turns OFF.
Output 1
Output 2
Switch output
Switch output
Switch output
Accumulated pulse output
Accumulated pulse output
Switch output
Accumulated pulse output
1234
Accumulated pulse output