Datasheet

How to Order
Integrated
Display Type
15
04
20
40
11
0.5 to 4 l/min
2 to 16
l/min
5 to 40
l/min
10 to 100
l/min
27
67
Output specification
NPN open collector 2 outputs
PNP open collector 2 outputs
PF2W7 20 03 27
Flow rate range
Nil
N
F
Thread type
Rc
NPT
G
Nil
M
With unit switching function
Fixed SI unit
Note)
Unit specification
Water
Karman vortex
3-digit, 7-segment LED
NPN open collector: Maximum load current: 80 mA; Internal voltage drop: 1 V or less (with load current of 80 mA); Maximum applied voltage: 30 V; 2 outputs
PNP open collector: Maximum load current: 80 mA; Internal voltage drop: 1.5 V or less (with load current of 80 mA); 2 outputs
NPN or PNP open collector (same as switch output)
l/min, gal(US)/min
l, gal(US)
0 to 1 MPa
1.5 MPa
0 to 999999
l
Operating: 0 to 50°C, Stored: –25 to 85°C (with no freezing and condensation)
Illuminates when output is ON, OUT1: Green; OUT2: Red
1 sec. or less
Hysteresis mode: Variable (can be set from 0), Window comparator mode
Note 6)
: 3-digit fixed
12 to 24 VDC (ripple ±10% or less)
Model
Measured fluid
Flow rate measurement range
Set flow rate range
Rated flow range
Minimum set unit
Accumulated pulse flow rate exchange value (Pulse width: 50 ms)
Operating fluid temperature
Linearity
Repeatability
Temperature characteristics
Note 1)
Current consumption (No load)
Weight
Note 2)
Port size (Rc, NPT, G)
Detection type
Indicator light
Operating pressure range
Proof pressure
Accumulated flow range
Note 4)
Ambient temperature range
Status LED’s
Response time
Hysteresis
Power supply voltage
Real-time flow rate
Accumulated flow
Display units
Note 1) In the case of PF2W711, ±3% of F.S. or less (15°C to 35°C, based on 25°C). Note 2) Without lead wire.
Note 3) For digital flow switch with unit switching function. (Fixed SI unit [l/min or l] will be set for switch type without the unit switching function.)
Note 4) Accumulated flow rate is reset when the power supply turns OFF. Note 5) Switch output and accumulated pulse output can be selected during initial setting.
Note 6) Window comparator mode — Since hysteresis will reach 3 digits, keep P_1 and P_2 or n_1 and n_2 apart by 7 digits or more.
(In case of output OUT2, n_1, 2 to be n_3, 4 and P_1, 2 to be P_3, 4.) Note 7) This product conforms to the CE mark.
PF2W720PF2W704 PF2W740 PF2W711
460 g
3/8
700 g
1/2, 3/4
1150 g
3/4, 1
520 g
3/8, 1/2
0.35 to 4.5
l/min
0.35 to 4.5
l/min
0.5 to 4 l/min
0.05
l/min
0.05
l/pulse
3.5 to 45
l/min
3.5 to 45
l/min
5 to 40 l/min
0.5
l/min
0.5
l/pulse
7 to 110
l/min
7 to 110
l/min
10 to 100 l/min
1
l/min
1
l/pulse
1.7 to 17.0
l/min
1.7 to 17.0 l/min
2 to 16
l/min
0.1 l/min
0.1
l/pulse
±5% F.S. or less
±3% F.S. or less
70 mA or less
±3% F.S. or less
±2% F.S. or less
80 mA or less
Switch output
Accumulated pulse output
Output
specifications
PF2W704, PF2W720
PF2W720, PF2W740
PF2W740, PF2W711
PF2W711
Port size
Symbol
03
04
06
10
3/8
1/2
3/4
1
4
16
40
100
Port
size
Applicable model
Flow rate (
l/min)
Enclosure
Operating temperature range
Withstand voltage
Insulation resistance
Vibration resistance
Impact resistance
Noise resistance
IP65
0 to 50°C
1000 VAC for 1 min. between external terminal and case
50M or more (500 VDC Mega) between external terminal and case
10 to 500 Hz with a 1.5 mm amplitude or 98 m/s
2
acceleration in each X, Y, Z direction for 2 hrs, whichever is smaller.
490 m/s
2
in
X, Y, Z directions 3 times each
1000 Vp-p, Pulse width 1 µs, Rise time 1 ns
±5% F.S. or less (0 to 50°C, based on 25°C)
0 to 50°C
M
Nil
N
Lead wire (Refer to page 35.)
M12 3 m lead wire with connector
Without lead wire
Series
PF2W
Digital Flow Switch
For Water
Refer to www.smcworld.com for details of
products compatible with overseas standards.
Note) Fixed units:
Real-time flow rate:
l/min
Accumulated flow:
l
Specifications
Note 3)
Note 5)
Resistance