Datasheet

3
Analogue Output
Flow rate
Output
A
C
B
0
Min. rated
flow
Max. rated
flow
Note 1) Refer to “Applicable Fluids List” on page 17.
Note 2)
When fluids with high temperature are used, the available pressure range will be reduced. (For details, refer to “Operating Pressure Range” on page 4.)
Note 3) The response time until the set value reaches 63% in relation to the step input.
Note 4) When options are used, add the weight of the optional parts.
Note 5) Piping port and the metal part of the body are grounded to DC(–)/blue line. Power supply with positive ground cannot be used. Please consult SMC
if the product is used for positive ground environment.
Model
LFE1 LFE2 LFE3
Applicable fluid
Note 1)
Applicable fluid conductivity
Note 1)
Detection method
Ground
Note 5)
Rated flow range
Operating fluid temperature
Note 2)
Repeatability
Temperature
characteristics
Operating pressure range
Note 2)
Proof pressure
Note 2)
Analogue
output
Power supply voltage
Current consumption
Standards and regulations
Parts material in contact with fluid
Port size
Weight (Body)
Note 4)
Response time
Note 3)
Voltage output
Current output
Enclosure
Operating temperature range
Operating humidity range
Environmental
resistance
Ambient temperature
Fluid temperature
Water, Conductive fluids which do not corrode the fluid contact materials.
Note 1)
5 μS/cm or more (micro siemens)
Electrostatic capacity type
Negative ground
0 to 85°C (with no freezing and condensation)
Analogue output: ±1.5% F.S.
±5% F.S. (25°C reference)
±5% F.S. (25°C reference)
0 to 1 MPa
2 MPa
0.5 s
Output voltage: 1 to 5 V Output impedance: 1 kΩ
Output current: 4 to 20 mA Max. load impedance: 600 Ω
24 VDC ±10%
42 mA or less (Load current is not included.)
IP65
0 to 50°C (with no freezing and condensation)
Operating, Storage: 35 to 85% R.H. (with no condensation)
CE marking, RoHS
PPS, FKM, C37 (Brass)
2.5 to 100 L/min 5 to 200 L/min0.5 to 20 L/min
3/8 (10A)
Approx. 335 g
3/4 (20A)
Approx. 515 g
1 (25A)
Approx. 675 g
1/2 (15A)
Approx. 395 g
Specifications (Remote Type Sensor Unit)
Refer to page 9 for the monitor unit specifications.
Flow/Analogue output
Voltage output
Current output
1 V
4 mA
A
1.1 V
4.4 mA
B
5 V
20 mA
C
LFE1
LFE2
LFE3
0.5
2.5
5
Minimum
Rated flow [L/min]
20
100
200
Maximum
Model
Analogue output