Datasheet

2
Air purge: No
Horizontal distance to the ionizer - Charged object location (mm)
Electricity removal range
Front/Rear distance to the ionizer - Charged object location (mm)
100 mm
100 mm
Height 100 mm
Height 300 mm
Height 500 mm
Air purge: Yes (0.05 MPa to 0.7 MPa)
Horizontal distance to the ionizer - Charged object location (mm)
Electricity removal range
Front/Rear distance to the ionizer - Charged object location (mm)
100 mm
100 mm
Height 500 mm
Height 1000 mm
Height 1500 mm
Height 2000 mm
Ion balance (V)
Installation height of feedback sensor (mm)
90
60
30
0
–30
–60
–90
0 100 200 300 400 500
Catalogue specification value: ±30 V
Air purge: Yes (0.1 MPa)
2) Installation height of feedback sensor and discharge time / Ion balance
Discharge time (sec)
Installation height of feedback sensor (mm)
8
7
6
5
4
3
2
1
0
0 100 200 300 400 500
Discharge time from 1000 V to 100 V
Without sensor
With feedback sensor
Charged plate
Feedback sensor
Ionizer
Installation height of feedback sensor
600 mm
1) Static electricity removal range / Ionizer depth direction
Static electricity Removal Characteristics
Series IZS31
Technical Data 2
Note) Static electricity elimination features are based on data from using a charged plate (size: 150 mm x 150 mm, capacitance: 20 pF) as defined in the U.S. ANSI standards