1. Install the ionizer away from a wall as illustrated
below.
If a wall is located closer than the illustration below, the ions
generated will not be able to reach the object which requires
static electricity removal and therefore result in a decrease in
efficiency.
Caution
Unit: mm
200 200 150 150
After installation, be sure to verify the effects of
static electricity removal.
The effects vary depending on the ambient conditions,
operating conditions, etc. After installation, verify the effects of
static electricity removal.
2. Install a feedback sensor away from the wall as
illustrated below.
The ionizer may fail to measure electrostatic potentials
correctly if a wall or other obstacle exists within the clearances
shown in the following figure.
1. Before wiring confirm if the power supply voltage
is enough and that it is within the specifications
before wiring.
2. Be sure to provide class-D grounding in order to
maintain product performance.
If such grounding is not provided, not only may the ion balance
be disrupted but electric shocks may also result and the
ionizer or power supply may break down.
3. Be sure to turn off the power supply before
wiring (including attachment/detachment of the
connector).
4. To connect a feedback sensor or autobalance
sensor to the ionizer, use the cable included with
the sensor. Do not disassemble or modify the
ionizer.
5. When applying the power supply, pay special
attention to the wiring and/or surrounding
environment until safety is confirmed.
6. Do not connect or remove any connectors
including the power supply, while power is being
supplied. Otherwise, the ionizer may malfunction.
7. If the power line and high pressure line are
routed together, this product may malfunction
due to noise. Therefore, use a separate wiring
route for this product.
8. Be sure to confirm there are no wiring errors
before starting this product.
Incorrect wiring will lead to damage or malfucntion to the
product.
9. Flush the piping before using.
Before using this product, exercise caution to prevent
particles, water drop, or oil from entering the piping.
Warning
B
B
A
B
A
Charged object Charged object
B
20
40
45
55
65
75
A
10
20
25
30
40
50
(mm)
GND
+24 VDC
Class-D ground
DC power supply
Blue
Brown
Specific Product Precautions 2
Be sure to read this before handling.
Series IZS31
Mounting
Wiring / Piping