Determining the Model and Settings 2 / Pulse DC Mode
1) Selection of bar length
· Determine the length suited for a work size, referring to the “Static electricity Removal Characteristics” and “Static electricity Removal
Range”, etc.
2) Installation of the ionizer
· Install the ionizer within 50 to 2000 mm of the object requiring electricity removal. However, install the main unit at a distance from
100 to 2000 mm when using an autobalance sensor. Although the main unit can also be used at other distances, it may fail to
operate normally depending on the conditions of use. Before use, always verify that the main unit is functioning normally.
3) Installation of the sensor
· When adjusting the ion balance using a sensor, install an autobalance sensor.
· Install the sensor immediately below the ionizer so that it is level with the workpiece.
· When an autobalance sensor is connected, the ion balance adjustment trimmer settings are nullified.
4) Configuration of maintenance level selection switch
· This switch is used to select “Manual Operation” or “Automatic Operation” when an autobalance sensor is connected to adjust the ion
balance.
When an autobalance sensor is not used.
When an autobalance sensor is not used, set the switch to AUTO. Then, adjust the ion balance manually using the ion balance
adjustment trimmer.
· Configuration of dirt-detection level on an electrode needle.
· Set the switch to either H (high), M (middle) or L (low). At settings other than these, the ionizer does not perform electrode needle
dirt-detection
· Dirt-detection starts when the maintenance start signal is input.
· When the switch is set to H, M or L, the ionizer performs electrode needle stain-detection and then adjusts the ion balance.
AUTO MANUAL
Details of operation
Switch setting
Manual
operation
Automatic
operation
MANUAL
AUTO
When a maintenance start signal is input or the ionizer is turned on, the ionizer
detects electrode needle contamination according to ion balance adjustment and
detection level settings.
An ion balance adjustment value for each ion generation frequency is retained.
When the ion generation frequency is changed, adjust the ion balance.
After adjustment, the autobalance sensor may be removed as ion balance
adjustment will not be performed again until a maintenance start signal is input.
The ionizer continuously adjusts the ion balance. When the autobalance sensor is
removed, adjust the ion balance manually using the ion balance adjustment trimmer.
∗
Set the switch according to the dirt-detection level.
Ion balance adjustment trimmer
H (High) Level not influential to the discharge time
M (Middle) Level immediately before the discharge time elongates.
L (Low) Level at which the discharge time is longer than it initially was.
Series IZS31
2. Pulse DC mode