Datasheet

7
Specifications
Number of Electrode Cartridges and Weight
Sensor
Construction
Bar length (mm)
Number of electrode cartridges
Weight (g)
Operating ambient temperature
Operating ambient humidity
Case material
Vibration resistance
Shock resistance
Weight
Installation distance
Compliance with overseas standards / directive
0 to 50°C
35 to 80%Rh (With no condensation)
Durability 50 Hz Amplitude 1 mm XYZ each 2 hours
10 G
ABS
200 g (Including cable weight)
10 to 50 mm (Recommended)
CE (EMC directive: 89/336/EEC, 92/31/EEC, 93/68/EEC, 2004/108/EC,
Low voltage directive: 73/23/EEC, 93/68/EEC)
ABS, Stainless steel
220 g (Including cable weight)
300
3
470
380
4
530
620
7
720
780
9
850
1100
13
1100
1260
15
1220
1500
18
1410
1900
23
1730
2300
28
2040
Sensor model
IZS31-DF
(Feedback sensor)
IZS31-DG
(Autobalance sensor)
1
2
3
4
5
6
7
8
DescriptionNo.
Ionizer
Electrode cartridge
One-touch fitting
End bracket
Centre bracket
Feedback sensor
Autobalance sensor
Power supply cable
r
t
q
e
i
u
w
y
Note 1) For the case where air purge is performed between a charged object and an ionizer at a distance of 300 mm.
Note 2) For cases where the potential of a charged object is measured using a feedback sensor, the relationship between the potential being measured, the sensor monitor output
voltage and the detection range of the sensor will vary depending on the sensor’s installation distance. Refer to page 3.
Fluid
Operating pressure
Connecting tubing O.D.
Sensing DC mode
Pulse DC mode
DC mode
Emission of static electricity is suspended.
Maintenance
Static electricity removal is completed.
Maintenance output
Irregularity
Sensor monitor output
Note 2)
IZS31-P (PNP specification)IZS31- (NPN specification)
Corona discharge type
Sensing DC, Pulse DC, DC
±7000 V
±30 V (Stainless electrode needle: ±100 V)
Air (Clean and dry)
0.7 MPa or less
ø4
24 VDC ±10%
200 mA or less (While standing by: 120 mA or less)
200 mA or less (When sensor is not used: 170 mA or less)
170 mA or less
Contact input signal with no voltage
Voltage output 1 to 5 V (Connect a 10 k or larger load.)
50 to 2000 mm (Sensing DC mode: 200 to 2000 mm)
0 to 50°C
35 to 80%Rh (With no condensation)
Cover of ionizer: ABS, Electrode needle: Tungsten, Monocrystal silicon, Stainless steel
Durability 50 Hz Amplitude 1 mm XYZ each 2 hours
10 G
Ionizer model
CE (EMC directive: 89/336/EEC, 92/31/EEC, 93/68/EEC, 2004/108/EC,
Low voltage directive: 73/23/EEC, 93/68/EEC)
Max. load current: 100 mA
Residual voltage: 1 V or less (At load current 100 mA)
Max. applied voltage: 28 VDC
Max. load current: 100 mA
Residual voltage: 1 V or less (At load current 100 mA)
Ion generation method
Method of applying voltage
Output for emitting electricity
Ion balance
Note 1)
Air purge
Power supply voltage
Input signal
Output signal
Effective discharge distance
Operating ambient temperature, Operating fluid temperature
Operating ambient humidity
Material
Vibration resistance
Shock resistance
Compliance with overseas standards / directives
Current
consumption
Ionizer Series IZS31