User Manual

- 5 -
2. Specifications
Model number of ionizer IZN10-□□
(NPN)
IZN10-□□P
(PNP)
Ion generating method Corona discharge type
Voltage applying method High frequency AC type
Discharge output
Note 1)
2500V
Ion balance
Note 2)
±10 V at max.
Ozone generated amount
Note 3)
0.03 ppm (0.05 ppm for energy saving charge
elimination nozzle
Fluid
Air (clean and dry)
Operating pressure
Note 4)
0.05 MPa~0.7 MPa
Air
purge
Connected tube diameter 6 and 1/4 inch
Power supply voltage
24VDC±10%
Current consumption
80 mA
(When input and output signals are not used)
Discharge stop signal
Reset signal
Input
signal
External switch signal
GND to connection
The voltage to turn on is 0.6V
or less.
Current consumption: 5 mA or
less
+24V to connection
The voltage to turn on is from
+19V to the
power supply voltage.
Current consumption: 5 mA
or less
Discharge signal
Error signal
Output
signal
Maintenance signal
Max. load current: 40 mA
Residual voltage: 1 V or less
(with load current of 40 mA)
Max. applied voltage: DC 28
V
Max. load current: 40 mA
Residual voltage: 1 V or less
(with load current of 40 mA)
Effective charge eliminating distance 20~500 mm
Ambient temp.
Fluid temp.
0~55
o
C
Ambient humidity
35~65% RHWith no condensation
Material
Body: ABS, Stainless Nozzle: Stainless
Electrode needle: Tungsten
Vibration resistance
Durable to 50 Hz with amplitude 1 mm for 2 hours in
each X, Y and Z direction
Impact resistance
10 G
Weight
120 g
Applicable standard/directive
CE (EMC directive: 89/336/EEC, 92/31/EEC
93/68/EEC, 2004/108/EC, Low-voltage directive:
73/23/EEC, 93/68/EEC)
Note 1) This is the value when measured by a probe with 1,000 M and5 pF.
Note 2) This specification is applicable when the distance between the charged object and the
ionizer is 100 mm using the power saving static elimination nozzle, and the air purge
pressure is 0.3 MPa.
Note 3) This is the value from which the background is drawn with a distance of 300 mm from the
front face of the nozzle.
Note 4) Charge elimination is not available without air purge. Also, without air purge, internal
ozone concentration will increase and adversely affect the product and peripheral
equipment.