User Manual
- 16 -
4-4. Power supply cable wiring diagram
4-5. Timing chart
Timing chart
Remarks
The discharge of ion is started
when a static elimination stop
signal is turned on
Power supply on
High voltage error
Maintenance required period
The error signal can be
reset by turning on and
off the reset signal.
External switch signal on
Error signal
Maintenance signal
External switch signal 1,2
Ion is emitted even while
the maintenance signal is
on.
The signal is turned off
when error occurs.
Output
Output
Input
Power supply
Discharge stop signal
Reset signal
Discharging signal
(ON The signal turns on when
ion is discharged)
Input
Input
Input
Output
ON
OFF
Clean electrode
needles with the
p
ower su
pp
l
y
off
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Maintenance re
q
uired
Error occurred
+ Power supply
GND DC24V±10%
Brown +24V
Blue GND
INPUT
+24V
PLC
Pink Discharge stop signal
Pink Reset signal
or
or
Ionizer
OUTPUT
INPUT
White Discharging signal
Yellow Maintenance signal
Purple Error signal
OUTPUT
OUTPUT
or
or
INPUT
Class D grounding of external metal parts
(No electricity conduction to internal circuit)
Internal circuit
■ NPN
Gray External switch signal
Light blue External switch signal
+ Power supply
GND DC24V±10%
Brown +24V
Blue GND
INPUT
+24V
PLC
Ionizer
OUTPUT
INPUT
OUTPUT
or
or
OUTPUT
INPUT
Internal circuit
+24V
+24V
+24V
or
or
Pink Discharge stop signal
Pink Reset signal
White Discharging signal
Yellow Maintenance signal
Purple Error signal
Class D grounding of external metal parts
(No electricity conduction to internal circuit)
Gray External switch signal
Light blue External switch signal
■ PNP