Datasheet

1
In compliance with input, inverse proportional pressure is displayed.
Reverse Type
2
ITV20 X102
ITV10 X102
ITV30 X102
High Pressure Type (SUP 1.2 MPa, OUT 1.0 MPa)
3
ITV20 X224
ITV10 X224
ITV30 X224
0
0 100
Output pressure
(MPa)
This range is
outside of the
control (output).
0.005 MPa
Rated
pressure
5
5
5
Set Pressure Range 1 to 100 kPa
4
ITV20 X25
ITV10 X25
1
1
Note 1) in part number is the same model no. for the standard products.
Note 2) Except for preset input type and digital input type.
Note 3) For communication models, consult SMC for availability.
Note) For preset input type, digital input type and communication models,
consult SMC for availability.
Note) For preset input type, digital input type and communication models,
consult SMC for availability.
Input/output characteristics chart
Input signal (%F.S.)
Reverse type
High pressure type (SUP 1.2 MPa, OUT 1.0 MPa)
Set pressure range 1 to 100 kPa
ITV20 X2564
ITV10 X2564
Monitor Analogue output 4-20mA (source type/-COM)
Note 1) in part number is the same model no.
for the standard products.
Made to Order Specifications 1
Series ITV1000/2000/3000
Please contact SMC for detailed dimensions, specifications and lead times.
Made to
Order
RoHS
®
25