Brochure

How to Order
ITV
Pressure range
3
0
1 0
1
3
5
0.1 MPa
0.5 MPa
0.9 MPa
S Q
0 1 2
2
3
4
5
MPa
kgf/cm
2
bar
psi
kPa
Input signal
0
1
2
3
4
CC
DN
PR
RC
Cable connector type
S
L
N
Straight type 3 m
Right angle type 3
m
Without cable connector
Bracket
B
C
Without bracket
Flat bracket
L-bracket
Monitor output
0
1
2
3
4
Thread type
N
T
F
Rc
NPT
NPTF
G
Port size
1
2
3
4
1/8 (1000 type)
1/4 (1000, 2000, 3000 type)
3/8 (2000, 3000 type)
1/2 (3000 type)
Power supply voltage
0
1
24 VDC
12 to 15 VDC
Model
1
2
3
1000 type
2000 type
3000
type
Note)
Note)
Current type 4 to 20 mA (Sink type)
Current type 0 to 20 mA (Sink type)
Voltage type 0 to 5 VDC
Voltage type 0 to 10 VDC
Preset input
CC-Link
DeviceNet™
PROFIBUS DP
RS-232C communication
None (for communication models)
None (for preset input)
Analogue output 1 to 5V DC
Switch output/NPN output
Switch output/PNP output
Analog output 4 to 20 mA (Sink type)
Note) Communication
models are availa-
ble only for 24 V
DC
Pressure display unit
Made to Order Specifications
See pages 11, 25, and 26 for details.
CE compliant
Q
CE compliant
For detailed information on
CE marked models, refer to
SMC's website.
Note) Only for overseas sales (SI units are
to be used inside Japan). No units are
displayed on communication models.
Note) Communication cable (other than RS-
232C) should be obtained separately.
See below.
Application
CC-Link compatibility
DeviceNet™
compatibility
PROFIBUS DP
compatibility
Communication cable part number
PCA-1567720 (Socket type)
PCA-1567717 (Plug type)
PCA-1557633 (Socket type)
PCA-1557646 (Plug type)
PCA-1557688 (Socket type)
PCA-1557691 (Plug type)
Remarks
Dedicated Bus adapter supplied
with the product.
T-branch connector not supplied.
T-branch connector not supplied.
For communication cables, use the parts listed below
(refer to the catalogue [M8/M12 Connector] CAT.EUS100-73-UK for details)
or order the product certified for the respective protocol (with M12 connector) separately.
Electro-Pneumatic Regulator
Series
ITV1000/2000/3000
Model
Maximum supply pressure
Minimum supply pressure
24 VDC ± 10%, 12 to 15 VDC
Set pressure +0.1 MPa
Set pressure range
Note 1)
0.2 MPa
Input signal
Input
impedance
Output pressure
display
Note 4)
Weight
Note 9)
Accuracy
Minimum unit
ITV10
ITV20

ITV30

Ambient and fluid temperature
Enclosure
1.0 MPa
0.005 to 0.1 MPa 0.005 to 0.5 MPa 0.005 to 0.9 MPa
JIS Symbol
4 to 20 mA, 0 to 20 mA (Sink type)
0 to 5 VDC, 0 to 10 VDC
4 points
250
or less
Note 6)
Approx. 6.5 k
Approx. 2.7
k
Linearity
Hysteresis
Repeatability
Sensitivity
Temperature characteristics
Power supply
Voltage
Current
consumption
Within ±1% (Full span)
Within 0.5% (Full span)
Within
±0.5% (Full span)
Within 0.2% (Full span)
Within ±0.12% (Full span)/°C
±3% (Full span)
MPa: 0.01, kgf/cm
2
: 0.01, bar: 0.01, PSI: 0.1
Note 5)
, kPa: 1
0 to 50
°C (No condensation)
IP65
Approx. 250 g (without options)
Approx. 350 g (without options)
Approx. 645 g (without options)
NPN open collector output: Max. 30 V, 30 mA
PNP open collector output: Max. 30 mA
Power supply voltage 24 VDC type: 0.12 A or less
Power supply voltage 12 to 15 VDC type: 0.18 A or less
ITV105
ITV205
ITV305
ITV103
ITV203
ITV303
ITV101
ITV201
ITV301
1 to 5 VDC (Load impedance: 1 k or more)
4 to 20 mA (Sink type) (Load impedance: 250
or less)
Output accuracy within
±6% (Full span)
Input/output characteristics chart
Input signal (%F.S.)
0
0 100
Output pressure
(MPa)
This range is outside
of the control (output).
0.005MPa
Rated pressure
ITV3000 Fieldbus-compatible
model
ITV2000ITV1000
Note 1) Please refer to Figure 1 for the relationship between set pressure and input. Because the maximum set pres-
sure differs for each pressure display, refer to Appendix 7.
Additionally, refer to page 18 for the set pressure range by units of standard measured pressure.
Additionally, refer to page 18 as maximum set pressure differs on unit of standard measure.
Note 2) 2-wire type 4 to 20 mA is not available. Power supply voltage (24 VDC or 12 to 15 VDC) is required.
Note 3) Select either analogue output or switch output.
Further, when switch output is selected, select either NPN output or PNP output.
Note
4)
Adjustment of numerical values such as the zero/span adjustment or preset input type is set based on the mi-
nimum units for output pressure display (e.g. 0.01 to 0.50 MPa). Note that the unit cannot be changed.
Note 5) The minimum unit for 0.9 MPa (130 psi) types is 1 psi.
Note 6)
Value for the state with no over current circuit included. If an allowance is provided for an over current circuit,
the input impedance varies depending on the input current. This
is 350 or less for an input current of 20
mA DC.
Note 7) The above characteristics are confined to the static state. When air is consumed on the output side, the pres-
sure may fluctuate.
Note 8) For communication models, the maximum current consumption is 0.16 A or less.
Note 9) For communication models, add roughly 80 g to the weight (100 g for the PROFIBUS DP).
Note 10) The ITV1000 series is a non-grease model (Wetted parts).
Standard Specifications
Note 10) Note 10) Note 10)
Current type
Note 2)
Voltage type
Preset input
Current type
Voltage type
Preset input
Switch
output
Analogue
output
Output signal
(monitor
output)
Note 3)
Protocol
Version
Note 1)
Configulation file
Note 2)
I/O occupation area
(input/output data)
Communication data resolution
Fail safe
Note 4)
Terminating
resistance
Communication
speed
Communication Specifications
Model
ITV00-CC
CC-Link
Ver 1.10
12 bit (4096 resolution)
ITV00-DN
DeviceNet™
Release2.0
EDS
16 bit/16 bit
12 bit (4096 resolution)
ITV00-PR
PROFIBUS DP
DP-V0
GSD
16 bit/16 bit
12 bit (4096 resolution)
CLEAR
ITV00-RC
RS-232C
9.6 kbps
10 bit (1024 resolution)
HOLD
Note 1) Note that this version information is subject to change.
Note 2) Configulation files can be downloaded from SMC's website: http://www.smc.eu
Note 3) The output HOLD value when a CC-Link communications error occurs can be set based on the bit area data.
Note 4) It shows the insulation between electric signal for communication and the ITV supply power.
156 k/625 k
2.5 M/5 M/10 M bps
125 k/250 k/500 k bps
9.6 k/19.2 k/45.45
k
93.75 k/187.5 k/500
k
1.5 M/3 M/6 M/12 M bps
Built into the product
(Switch setting)
HOLD/CLEAR
(Switch setting)
4 word/4 word, 32 bit/32 bit
(per station, remote device station)
HOLD
Note 3)
/CLEAR
(Switch setting)
Electro-Pneumatic Regulator
Series ITV1000/2000/3000
9