Operation Manual
4 Maintenance 
4 - 4 
【IDF15E】 
・  O
pen the residual pressure release cock at the drain 
tube connection port to release air and drain fluid left 
in the product. 
(Leave the drain tube connected and hold it with hand 
so that it does not get twisted.)  
・  Remove the tube while pushing the release bush. 
・  Hold the case assembly lightly and pull down the lock button 
with thumb.Then, turn the case assembly to the left (or right) 
to 45°to align the marks,Release your thumb from the lock 
button and slowly pull down the case assembly (vertically) 
to remove it. 
・  Remove the auto drain strainer and clean it. Take care not 
to cut your hand with the sharp edges of the strainer. 
・  Pour solution of neutral detergent into the case assembly 
and shake it well to clean. 
・  Check the case O-ring for damage such as scratches, 
twisting or foreign particles attached to it. Then, apply 
grease thinly and fit it in the groove in the case assembly. 
・  Fit the auto drain strainer to the case assembly and fit it into 
the drain separator body. Turn it untill the lock button clicks. 
Try to turn the case assembly lightly and check that it does 
not turn. If it turns, start with fitting the case assembly to the 
body again. 
・  Close the residual pressure release cock and mount the 
drain tube and front panel as they were. 
・  If the auto drain strainer or case assembly is damaged or 
very dirty, replace it with a new one. 
Drain tube 
Open 
Close 
Residual pressure 
release cock 
Drain tube 
release bush 
Lock button
Lock button 
Mark 
To remove the case assembly, turn it to 
45
°until the lock button and mark align.  
Then, pull it down slowly. 
S
O
Auto drain strainer
"O"ring
Lock button
Case assembly
Residual pressure
release cock
Release bush