Operation Manual
   3 Operation / Shutdown 
3 - 1 
3 
      Operation / Shutdown 
Caution 
No one but someone who has enough knowledge and experience about the product and 
incidental devices should operate or shut down the product. 
3-1  Check points before operation 
Before a trial running, check following points. 
• Installed Condition 
By visual inspection check that the product is installed horizontally. 
  The product make sure the product is fixed enough with anchor bolts. 
Do not place heavy obstacles on the product and add unreasonable loading by piping and so on. 
• Wiring Connections 
Power cord, and the earth should be connected firmly. 
• Drain Tube 
Drain tube should be connected correctly. 
• Air Piping 
Make sure the piping for compressed air is connected correctly. Those valves of IN / Out side of the product  and 
of the bypass piping should be completely fasten. 
3-2 Operation 
Start operation according to the procedure below. 
•  Turn on the breaker of the main power supply. Then, turn on the illuminated switch. 
•  The lamp will light up. Few minutes later, the cooling fan will rotate and hot air will be exhausted from the 
ventilation grille. 
Place of the ventilation grille: IDF1E ~ 3E: Top Ventilation Grille 
IDF4E ~ 15E: Right Side Ventilation Grille 
•  Open the IN / Out side valve slowly. Make sure the bypass valve is completely closed. Confirm there is no air 
leakage. 
•  Depending on the condition of compressed air or ambient temperature, the cooling fan sometimes alternates 
between rotation and stop at the beginning. Then, the refrigerator will go into continuous run and the pointer of 
the evaporation thermometer will indicate in the green zone. If the pointer of the evaporation thermometer 
indicates higher than the green zone, refer to “Chapter5 Troubleshooting.” 
•  After a while from the start of flowing the compressed air, drain will be discharged from the drain tube 
automatically. 
•  Keep the condition of continuous run to use. 