(7) If drain should flow into the case, remove it out through the drain port at the bottom of the case. The
drain port can also be used to exhaust residual pressure in addition to discharging the drain.
Pressurize the inside of the air filter when
discharging drain. Drain will not be discharged
properly if not pressurized.
Open and close drain cock by hand. The use of tools
can result in damage to the product.
After discharging the drain, tighten the drain cock
to the opposite direction by hand until the seal
inside seals correctly.
Caution
(1) Check the element periodically and replace it with a new one if necessary. If it is found that outlet
pressure drops or the flow is restricted, check the condition of the element.
Drain cock
OPEN
(Drain discharge)
2022-10-1811:23
DP 097499