Specifications

Electrostatic Discharge according to EN 61000-4-2: 2001 ED.1.2
(Contact Discharge: ±4 kV, Air Discharge: ±8 kV)
Radio-frequency electromagnetic field according to EN 61000-4-3: 2006 ED.3.0
(80 - 1000 MHz with 1 kHz AM 80% Modulation: 3 V/m)
Electrical fast transient/burst according to EN 61000-4-4: 2004 ED.2.0 (AC/DC
power supply: ±1 kV, Data/Signal lines: ±0.5 kV)
Surge immunity test according to EN 61000-4-5: 2005 ED.2.0
(AC/DC Line to Line: ±1 kV, AC/DC Line to Earth: ±2 kV)
Immunity to conducted disturbances, Induced by radio-frequency fields:
EN 61000-4-6: 2006 ED.2.2 (0.15 - 80 MHz with 1 kHz AM 80% Modulation: 3
V/m)
Power frequency magnetic field immunity test according to
EN 61000-4-8:
2001 ED.1.1 (1 A/m at frequency 50 Hz)
Voltage dips, short interruptions and voltage variations immunity test according to
EN 61000-4-11: 2004 ED.2.0 (>95% Reduction @10 ms, 30% Reduction @500 ms,
>95% Reduction @5000 ms)
LVD:
EN 60950-1:2006
5