Compact Cylinder New Remodeled with a new body to get more flexibility! Can mount small auto switches on 4 surfaces. Auto switches can be mounted on any of the 4 surfaces, depending on the installation conditions. (ø12 to ø25: 2 surfaces) Improved flexibility of system design. ø32 to ø200 ø12 to ø25 Auto switch mounting rail removed NEW A round slot for mounting small auto switches Available up to ø200 is provided on 4 surfaces.
NEW Series CQ2 Compact Cylinder Reduced by 5 to 13% NEW (Compared with SMC CQ2 series) Existing model Lighter weight Weight (Stroke 50 mm, built-in magnet, female thread and with (g) rubber bumper) The body strength (kinetic energy, allowable load, withstand pressure, etc.) is the same as the existing product.
Reduction in number of components No loss of components Reduction in labour for work NEW Auto switch 1 Insert the auto switch. 2 Fix the auto switch. Takes more labour and time Existing model because there are many components. It is likely to lose components Auto switch The nuts and screws may fall out when installed vertically. Auto switch The nut falls out! The auto switch can be replaced with the foot brackets mounted.
Series CQ2 Compact Cylinder Part numbers with rod end bracket and/or mounting bolt This reduces the steps to order the cylinder, rod end bracket, and mounting bolt separately. Applicable cylinders: C(D)Q2, C(D)Q2쏔쏔쏔-쏔S/-쏔T (Single acting) Reduction in labor for order Example) CDQ2B32-30DMZ- L Mounting bolt Nil W -M9BW Rod end bracket No mounting bolt Nil No bracket and bolt Simple joint A type + Joint Mounting bolt is shipped together.
Series CQ2 Compact Cylinder Added compact type foot brackets.
Series CQ2 Compact Cylinder Added pivot brackets for double clevis. 왎Rotating angle: Max. 100° (For ø12, ø16) Reduction in labour for design ¡Time to design rotating bracket saved. ¡Improved amount of mounting freedom ¡Can be mounted to an installed double clevis cylinder. Rotating angle 100° Double clevis pivot bracket Hexagon socket head cap screw for mounting pivot bracket Applicable cylinders: CQ2 (Bore size ø12 to ø100, Mounting bracket, Applicable only to double clevis.
Compact Cylinder Series CQ2 CQ2 12 16 20 25 32 40 50 63 80 100 125 140 160 180 200 ø12, ø16: 5 to 30 ø20, ø25: 5 to 50 ø32, ø40: 5 to 100 ø50 to ø100: 10 to 100 1 ø12, ø16: 5 to 30 ø20, ø25: 5 to 50 ø32, ø40: 5 to 100 ø50 to ø100: 10 to 100 26 ø12 to ø40: 5, 10 ø50: 10, 20 46 10 to 300 71 10 to 300 77 125 to 300 83 ø12, ø16: 5 to 30 ø20, ø25: 5 to 50 ø32, ø40: 5 to 100 ø50, ø63: 10 to 100 94 ø12, ø16: 5 to 30 ø20, ø25: 5 to 50 ø32, ø40: 5 to 100 ø50, ø63: 10 to 100 108 ø12, ø16: 5 to 30 ø
Combinations of Standard Products and Made Series CQ2 : Standard : Made to Order : Special product (For details, please contact SMC.) : Not available Made to Order: For details, refer to pages 201 to 235.
to Order Specifications Series CQ2 Double acting Double acting Single rod ø32 to ø100 Note 2) Double acting Single rod Double rod Single rod ø12 to ø63 ø12 to ø100 Note 4) Note 4) Note 1) Note 1) CQ2쏔S CBQ2 (Anti-lateral Load) (With End Lock) Note 12) Single acting Double acting Double acting Single rod/ Single rod/ Spring return Spring extend Single rod Single rod ø12 to ø50 ø32 to ø100 ø20 to ø100 Note 2) Note 3) Note 4) Note 12) Note 3) Standard CQP2 (Axial Piping) Large
Compact Cylinder: Standard Double Acting, Single Rod Series CQ2 ø12, ø16, ø20, ø25, ø32, ø40, ø50, ø63, ø80, ø100 How to Order Without auto switch 12 to ø25 CQ2 B 20 30 D Without auto switch ø32 to ø100 CQ2 B 32 30 D Z CDQ2 B 32 30 D Z L W M9BW With auto switch Mounting bolt With auto switch None L Shipped together ∗ Mounting bolt is shipped together only when the mounting bracket is “B”. ∗ For details about the mounting bolt sizes, refer to pages 5 and 10.
Compact Cylinder: Standard Double Acting, Single Rod Series CQ2 Specifications Pneumatic type Made to Order (For details, refer to pages 201 to 235.) Air-hydro type Bore size (mm) Action Fluid Proof pressure Maximum operating pressure Minimum operating pressure Ambient and fluid temperature Piston speed Cushion Stroke length tolerance 20 25 32 40 50 63 80 100 Double acting, Single rod Turbine oil Note) 1.5 MPa 1.0 MPa 0.18 MPa 0.
Series CQ2 Manufacture of Intermediate Strokes (Except air-hydro type) 1. Spacer-installed type 1: Standard model number Intermediate stroke with : Available in 1 mm intervals A spacer is installed on tubes with a stroke longer than the specified stroke ( Bore size (mm) 12, 16 20, 25 32, 40 50 to 100 Stroke range 1 to 29 1 to 49 1 to 99 1 to 99 Type 5 10 15 20 25 30 35 40 45 ).
Compact Cylinder: Standard Double Acting, Single Rod Series CQ2 Allowable Kinetic Energy Allowable Lateral Load at Rod End Load Weight and Piston Speed Without Auto Switch 1.
Series CQ2 Weight Weight Bore size (mm) 12 16 20 25 32 40 50 63 80 100 (g) 5 29 42 63 86 125 187 — — — — 10 35 50 75 100 145 208 339 480 916 1608 15 41 59 88 115 165 230 372 518 976 1688 Cylinder stroke (mm) 20 25 30 35 40 45 47 54 60 — — — 67 76 84 — — — 101 114 127 140 152 165 129 144 158 173 187 202 184 204 224 244 263 283 251 273 294 315 337 358 405 438 471 504 537 570 556 594 632 670 708 746 1036 1097 1157 1217 1277 1338 1768 1849 1929 2010 2090 2170 50 — — 178 216 303 380 603 784 1398 2251 75 —
Compact Cylinder: Standard Double Acting, Single Rod Series CQ2 Large Bore Size Standard Construction With boss on head side Built-in one-touch fittings Rod end male thread Non-rotating Rod Long Stroke With rubber bumper Anti-lateral Load Axial Piping Standard Component Parts 4 Collar 5 Retaining ring 6 7 8 Bumper A No.
Series CQ2 Clean Series 10 C Q2B Bore size D(M)Z Stroke ø12, ø16, ø20, ø25, ø32 ø40, ø50, ø63, ø80, ø100 Clean series Relief type 10 Vacuum type 11 Applicable for using inside the clean room graded Class 100 by making an actuator’s rod section a double seal construction and discharging by relief port directly to the outside of clean room. Specifications 12 Bore size (mm) 16 20 25 32 40 50 63 80 100 Double acting, Single rod Action 1.5 MPa Proof pressure Maximum operating pressure 1.
Compact Cylinder: Standard Double Acting, Single Rod Water Resistant Refer to pages 178 to 190 for details. With auto switch (Built-in magnet) R D Stroke Option Z M9BAL -XC6 Standard Bore size Water resistant 2-colour indication solid state auto switch Water resistant cylinder R NBR seals (Nitrile rubber) V FKM seals (Fluororubber) Large Bore Size CDQ2 Mounting Series CQ2 Made to Order Ideal for use under the atmosphere having coolant for machine tools, etc.
Standard: Double Acting, Single Rod Series CDQ2 With Auto Switch Refer to the below pages for further information on auto switches. Auto switch proper mounting position and its mounting height Minimum stroke for auto switch mounting P.193 to 199 Operating range Auto switch mounting brackets/Part no.
Compact Cylinder: Standard Double Acting, Single Rod Series CQ2 Mounting Bolt for CDQ2B/With Auto Switch Standard Large Bore Size Long Stroke Non-rotating Rod D Mounting bolt part no.
Series CQ2 Dimensions ø12 to ø25/Without Auto Switch Both ends tapped: CQ2A Both Ends Tapped R Bore size (mm) O1 12 16 20 25 Standard (Through-hole): Q R M4 x 0.7 7 M4 x 0.7 7 M6 x 1.0 10 M6 x 1.0 10 H thread effective depth C F 2 x M5 (Port size) 4 x øN through 8 x øO counterbore Z øD øI B + Stroke L E CQ2B (mm) M R O1 thread K M A + Stroke E With Boss on Head side (mm) With boss on head side Bore size G (mm) øTh9 12 16 20 25 1.5 1.5 2 2 Th9 15 – 00.043 20 – 00.052 13 – 00.
Compact Cylinder: Standard Double Acting, Single Rod Foot B + Stroke 12 16 20 25 LT LH LY Special cap bolt XY LG LS + Stroke YX (mm) Bore size Stroke range A (mm) (mm) LX LZ 5 to 30 5 to 30 5 to 50 5 to 50 B L L1 LD LG LH LS LT LX LY LZ X Y 35.3 17 13.5 24 4.5 2.8 17 5 36.8 18.5 13.5 25.5 4.5 2.8 19 6.5 2 34 29.5 44 8 4.5 2 38 33.5 48 8 5 41.2 19.5 14.5 28.5 6.6 4 24 7.5 3.2 48 42 62 9.2 5.8 44.7 22.5 15 32.5 6.6 4 26 7.5 3.2 52 46 66 10.7 5.
Compact Cylinder: Standard Double Acting, Single Rod Series CQ2 Double clevis: CQ2D 4xN Cap bolt CT øCB øCD hole H10 Axis d9 CX +0.4 +0.2 CZ –0.1 –0.3 CU L B + Stroke CW CL + Stroke A + Stroke Rod end male thread L1 13 RR Double Clevis Bore size Stroke range A (mm) (mm) 12 16 20 25 5 to 30 5 to 30 5 to 50 5 to 50 40.5 43 51 57.5 (mm) B CB CD CL CT CU CW CX CZ L L1 17 18.5 19.5 22.5 12 5 14 5 20 8 24 10 34.5 37 42 47.5 4 4 5 5 7 10 12 14 N 14 5 10 3.5 14 M4 x 0.7 15 6.5 12 3.5 15.
Series CQ2 Dimensions R O1 thread Both Ends Tapped R Bore size (mm) 12 16 20 25 (mm) O1 R M4 x 0.7 7 M4 x 0.7 7 M6 x 1.0 10 M6 x 1.0 10 Large Bore Size Both ends tapped: CDQ2A Standard ø12 to ø25/With Auto Switch Standard (Through-hole): H thread effective depth C Auto switch EA Minimum lead wire bending radius 10 Long Stroke CDQ2B 쏔 V K M With Boss on Head Side (mm) E With boss on head side Bore size G (mm) ø16 to ø25 12 16 20 25 8 Th9 1.5 1.5 2 2 0 15 –0.043 0 20 –0.
Series CQ2 Foot Foot: CDQ2L B + Stroke Y LT X Y X LG LS + Stroke (mm) Bore size Stroke range A (mm) (mm) LX LZ LY Special cap bolt LH L 12 16 20 25 5 to 30 5 to 30 5 to 50 5 to 50 B L L1 LD LG LH LS LT LX LY LZ X Y 46.3 28 13.5 24 4.5 2.8 17 16 2 34 29.5 44 8 4.5 48.8 30.5 13.5 25.5 4.5 2.8 19 18.5 2 38 33.5 48 8 5 53.2 31.5 14.5 28.5 6.6 4 24 19.5 3.2 48 42 62 9.2 5.8 54.7 32.5 15 32.5 6.6 4 26 17.5 3.2 52 46 66 10.7 5.
Compact Cylinder: Standard Double Acting, Single Rod Series CQ2 CX +0.4 +0.2 CZ –0.1 –0.3 L CU B + Stroke CW CL + Stroke A + Stroke RR Bore size Stroke range A (mm) (mm) 12 16 20 25 5 to 30 5 to 30 5 to 50 5 to 50 51.5 55 63 67.5 (mm) B CB CD CL CT CU CW CX CZ L L1 28 30.5 31.5 32.5 12 5 14 5 20 8 24 10 45.5 49 54 57.5 4 4 5 5 7 10 12 14 N 14 5 10 3.5 14 M4 x 0.7 15 6.5 12 3.5 15.5 M4 x 0.7 18 8 16 4.5 18.5 M6 x 1.0 20 10 20 5 22.5 M6 x 1.
Series CQ2 Dimensions ø32 to ø50/With Auto Switch (In the case of without auto switches, the A, B, F, P and Q dimensions will be only changed. Refer to the dimension table.) Both ends tapped: CQ2A/CDQ2A O1 thread R R Both Ends Tapped Bore size (mm) Standard (Through-hole): CQ2B/CDQ2B Minimum lead wire bending radius 10 Auto switch F 32 40 50 4 x øN through 8 x øO counterbore O1 R M6 x 1.0 10 M6 x 1.0 10 M8 x 1.
(mm) Bore size Stroke range Without auto switch With auto switch L L1 LD LG LH LT LX LY (mm) (mm) A B LS A B LS YX LG LS + Stroke 40 50 47.2 57.2 53.7 63.7 56.7 66.7 23 33 29.5 39.5 30.5 40.5 7 33 17 17 38.5 6.6 17 57.2 13.5 63.7 39.5 23.5 17 38.5 6.6 23.5 7.5 66.7 40.5 17.5 18 43.5 9 17.5 Bore size (mm) LZ X A + Stroke Rod end male thread 30 3.2 57 57 4 33 3.2 64 64 5 39 3.2 79 78 Foot bracket material: Carbon steel Surface treatment: Nickel plated 4 x øLD LX LZ 4 Y 32 71 11.2 5.
Compact Cylinder: Standard Double Acting, Single Rod Series CQ2 Double clevis: CQ2D/CDQ2D Double Clevis CT 4xN Cap bolt øCD hole H10 Axis d9 CX+0.4 +0.2 CZ –0.1 –0.3 L B + Stroke CW CL + Stroke A + Stroke CU RR Bore size Stroke range Without auto switch (mm) (mm) A B CL 5 to 50 60 23 50 32 75, 100 70 33 60 5 to 50 68.5 29.5 58.5 40 75, 100 78.5 39.5 68.5 10 to 50 80.5 30.5 66.5 50 75, 100 90.5 40.5 76.
Series CQ2 Dimensions ø63 to ø100/With Auto Switch (In the case of without auto switches, the A, B dimensions will be only changed. Refer to the dimension table.) Both ends tapped: CQ2A/CDQ2A O1 thread R Both Ends Tapped R Standard (Through-hole): CQ2B/CDQ2B Minimum lead wire bending radius 10 Auto switch Q O1 R 63 80 100 M10 x 1.5 M12 x 1.75 M12 x 1.
Compact Cylinder: Standard Double Acting, Single Rod Series CQ2 Foot: CQ2L/CDQ2L L B + Stroke Foot LH LY Special cap bolt 63 80 LT 100 X Y Y X LG LS + Stroke (mm) Bore size Stroke range Without auto switch With auto switch L (mm) (mm) A B LS A B LS 10 to 50 75, 100 10 to 50 75, 100 10 to 50 75, 100 62.2 36 10 72.2 46 20 18 43.5 11 72.2 46 20 75 43.5 13.5 85 53.5 23.5 20 53.5 13 85 53.5 23.5 88 53 19 98 63 29 22 53.
Compact Cylinder: Standard Double Acting, Single Rod Double clevis: CQ2D/CDQ2D CT 4xN Cap bolt A + Stroke Rod end male thread 62.2 36 10 72.2 46 20 18 43.5 11 72.2 46 20 75 43.5 13.5 85 53.5 23.5 20 53.5 13 85 53.5 23.5 88 53 19 98 63 29 22 53.5 13 98 63 29 100 7 59 4.5 80 7 71 6 100 95 91.5 113 16.2 9 100 33.5 10 43.5 86 12 43.5 Double Clevis 118 114 140 19.5 11 63 137 136 162 23 12.
Series CQ2 Accessory Brackets Single Knuckle Joint I-G012, I-Z015A I-G02, I-G03 Double Knuckle Joint Y-G012, Y-Z015A Y-G02, Y-G03 I-G04, I-G05 I-G08, I-G10 Y-G04, Y-G05 Y-G08, Y-G10 øND hole H10 Axis d9 øND hole H10 Axis d9 ø ø Material: Carbon steel Surface treatment: Nickel plated Material: Cast iron Surface treatment: Nickel plated Material: Cast iron Surface treatment: Nickel plated Material: Carbon steel Surface treatment: Nickel plated (mm) Part no.
Compact Cylinder: Standard Double Acting, Single Rod Series CQ2 Simple Joint (CQ2): ø32 to ø100 T1 M W T2 V Large Bore Size U 2 x øD Standard Type A Mounting Bracket B Material: Chromium molybdenum steel (Nickel plated) (mm) 03 Applicable air cylinder bore size 03 05 08 10 For ø32, ø40 For ø50, ø63 For ø80 For ø100 Mounting bracket YA Type A mounting bracket YB Type B mounting bracket Joint YU Allowable Eccentricity Bore size (mm) YA-03 YA-05 YA-08 YA-10 32, 40 50, 63 80 100 Part no.
Double Clevis Pivot Bracket Bore size ø12 to ø25 Without auto switch With auto switch R R 4 x øCN CX−0.2 −0.4 øCD hole H10 CT A + Stroke øCD hole H10 CL M CZ CW −0.2 4 x øCN 쏔M 쏔CZ CW CX−0.4 CT A + Stroke CL (mm) Bracket part no. Bore size Stroke range CQ-C012 CQ-C016 CQ-C020 CQ-C025 12 16 20 25 5 to 30 5 to 30 5 to 50 5 to 50 A Without auto switch 34.5 37 42 47.5 With auto switch 45.5 49 54 57.5 CW CT CL CX CD 14 15 18 20 4 4 5 5 19 21 27 30 5 6.
Compact Cylinder: Standard Double Acting, Double Rod Standard Series CQ2W ø12, ø16, ø20, ø25, ø32, ø40, ø50, ø63, ø80, ø100 How to Order 32 30 D Z CDQ2W B 32 30 D Z M9BW With auto switch Auto switch (Built-in magnet) B A Large Bore Size CQ2W B Long Stroke With auto switch 30 D — Mounting Through-hole (Standard) L Both ends tapped LC F Foot Compact foot Flange applicable auto switches. Number of Auto switch auto switches mounting groove — 2 pcs.
Series CQ2W Specifications Pneumatic type 12 Bore size (mm) 16 20 Action 25 32 40 50 63 80 100 Double acting, Double rod Fluid Air Proof pressure 1.5 MPa Maximum operating pressure 1.0 MPa Minimum operating pressure 0.07 MPa 0.05 MPa Without auto switch: –10 to 70°C (No freezing) With auto switch: –10 to 60°C (No freezing) Ambient and fluid temperature Lubrication Not required (Non-lube) Symbol Piston speed Double acting, Double rod 0.022 0.038 0.055 0.09 0.15 0.26 0.46 0.77 1.
Compact Cylinder: Standard Double Acting, Double Rod 20 25 32 40 50 63 80 100 — M5 M5 M5 M5 TN TF — — — — — — — — — — — — — — — — — — — — — M5 M5 M5 Rc1/8 TN — — — — — — NPT1/8 NPT1/8 NPT1/4 NPT1/4 NPT3/8 NPT3/8 Note 1) Both ends tapped Built-in magnet 32 40 50 63 80 100 Note 1) Piping Pipe thread Rod end male
Series CQ2W Weight Theoretical Output (N) Bore size (mm) Operating pressure (MPa) 0.3 0.5 0.
Compact Cylinder: Standard Double Acting, Double Rod Series CQ2W Construction Standard Long Stroke Large Bore Size Standard With rubber bumper Built-in one-touch fittings Component Parts No.
Standard: Double Acting, Double Rod Series CDQ2W With Auto Switch Refer to the below pages for further information on auto switches. Auto switch proper mounting position and its mounting height Minimum stroke for auto switch mounting P.193 to 199 Operating range Auto switch mounting brackets/Part no.
Compact Cylinder: Standard Double Acting, Double Rod Series CQ2W Mounting Bolt for CDQ2WB/With Auto Switch Standard Large Bore Size Long Stroke Cylinder model C D Mounting bolt part no. CQ-M8 x 65L 65 CDQ2WB63-10DZ x 70L 70 -15DZ x 75L 75 -20DZ x 80L 80 -25DZ x 85L 85 -30DZ x 90L -35DZ 13.5 90 x 95L 95 -40DZ x 100L 100 -45DZ x 105L 105 -50DZ x 130L 130 -75DZ x 155L 155 -100DZ 70 CQ-M10 x 70L CDQ2WB80-10DZ x 75L 75 -15DZ x 80L 80 -20DZ x 85L 85 -25DZ x 90L 90 -30DZ x 95L -35DZ 12.
Series CQ2W Dimensions ø12 to ø25/Without Auto Switch Both ends tapped: CQ2WA O1 thread R Both Ends Tapped R (mm) Bore size (mm) O1 R 12 16 20 25 M4 x 0.7 M4 x 0.7 M6 x 1.0 M6 x 1.
Compact Cylinder: Standard Double Acting, Double Rod Series CQ2W L Special cap bolt Standard Foot: CQ2WL L + Stroke B + Stroke X Y LX LG Y X LS + Stroke 4 x øLD Long Stroke LT LH LY Large Bore Size Note) The positions of left and right width across flats are not constant. LZ A + 2 (Stroke) Rod End Male Thread 12 16 20 25 L1 + Stroke L1 A1 + 2 (Stroke) Foot A1 (mm) L1 73.2 24 77 25.5 83 28.5 94 32.
Compact Cylinder: Standard Double Acting, Double Rod Series CQ2W Flange: CQ2WF FV Note) The positions of left and right width across flats are not constant. FT L1 B + Stroke A + 2 (Stroke) FX FZ L2 + Stroke Rod end male thread 2 x øFD Rod End Male Thread Bore size (mm) L3 12 16 20 25 L4 + Stroke A1 + 2 (Stroke) Flange (mm) Bore size (mm) Stroke range (mm) 12 16 20 25 5 to 30 A 42.2 25.2 FD FT FV FX FZ L1 L2 4.5 5.5 25 45 55 13.5 3.5 5 to 30 43 26 4.5 5.
CQ2W Series Dimensions R (mm) Bore size (mm) O1 R 12 16 20 25 M4 x 0.7 M4 x 0.7 M6 x 1.0 M6 x 1.0 7 7 10 10 Note 1) The positions of left and right width across flats are not constant.
Compact Cylinder: Standard Double Acting, Double Rod Series CQ2W Foot: CDQ2WL B + Stroke L Note) The positions of left and right width across flats are not constant. L + Stroke LT LH LY Special cap bolt X Y Y X LX LZ LG LS + Stroke A + 2 (Stroke) 4 x øLD Rod end male thread Rod End Male Thread Bore size (mm) L1 12 16 20 25 L1 + Stroke A1 + 2 (Stroke) Foot A1 (mm) L1 80.4 24 87 25.5 95 28.5 104 32.
Series CQ2W Flange: CDQ2WF Note) The positions of left and right width across flats are not constant. FV 2 x øFD L1 L2 + Stroke B + Stroke A + 2 (Stroke) Long Stroke FX FZ FT Rod End Male Thread 12 16 20 25 L4 + Stroke A1 + 2 (Stroke) Flange A1 (mm) L3 L4 70.4 24 14 77 25.5 15.5 85 28.5 18.5 94 32.5 22.5 Axial Piping Bore size (mm) Non-rotating Rod Rod end male thread L3 (mm) FT FV FX FZ L1 49.4 32.4 4.5 5.5 25 45 55 13.5 3.5 L2 5 to 30 53 36 4.5 5.5 30 45 55 13.
CQ2W Series Dimensions ø32 to ø50/With Auto Switch (In the case of without auto switches, the A, B and P dimensions will be only changed. Refer to the dimension table.) Both ends tapped: CQ2WA/CDQ2WA R O1 thread Both Ends Tapped R Bore size (mm) 32 40 50 Standard (Through-hole): CQ2WB/CDQ2WB 2xP (Port size) O1 R M6 x 1.0 10 M6 x 1.0 10 M8 x 1.
Foot: CQ2WL/CDQ2WL L Note) The positions of left and right width across flats are not constant. L + Stroke 4 x øLD LX LZ LS + Stroke A + 2 (Stroke) Rod End Male Thread Non-rotating Rod L1 + Stroke L1 Long Stroke (mm) Bore size Stroke range Without auto switch With auto switch L1 (mm) (mm) A1 A1 107.5 5 to 50 32 117.5 38.5 117.5 75, 100 117 5 to 50 127 38.5 40 127 75, 100 127.5 10 to 50 50 137.5 43.5 137.
Compact Cylinder: Standard Double Acting, Double Rod Series CQ2W Flange: CQ2WF/CDQ2WF M FV Note) The positions of left and right width across flats are not constant. L1 FT B + Stroke A + 2 (Stroke) 4 x øFD FX FZ L2 + Stroke Rod End Male Thread Bore size Stroke range Without auto switch With auto switch L3 (mm) (mm) A1 A1 97.5 5 to 50 32 107.5 38.5 107.5 75, 100 107 5 to 50 117 38.5 40 117 75, 100 117.5 10 to 50 127.5 43.5 50 127.
CQ2W Series Dimensions Both Ends Tapped Bore size (mm) 63 80 100 Standard (Through-hole): Minimum lead wire bending radius 10 2xP (Port size) Note 1) The positions of left and right width across flats are not constant.
Compact Cylinder: Standard Double Acting, Double Rod Series CQ2W Foot: CQ2WL/CDQ2WL B + Stroke L + Stroke Note) The positions of left and right width across flats are not constant. LH LY L YX LT XY Special cap bolt LG 4 x øLD LX LZ LS + Stroke A + 2 (Stroke) Rod End Male Thread L1 + Stroke A1 + 2 (Stroke) L1 (mm) Bore size Stroke range Without auto switch With auto switch L1 (mm) (mm) A1 A1 129 10 to 50 63 139 43.5 139 75, 100 158 10 to 50 168 53.5 80 168 75, 100 167.5 10 to 50 177.5 53.
Compact Cylinder: Standard Double Acting, Double Rod Series CQ2W 4 x øFD Rod End Male Thread Rod end male thread L3 Bore size Stroke range Without auto switch With auto switch L3 (mm) (mm) A1 A1 119 10 to 50 63 129 43.5 129 75, 100 148 10 to 50 158 53.5 80 158 75, 100 157.5 10 to 50 167.5 53.5 100 167.5 75, 100 L4 + Stroke (mm) L4 33.5 43.5 43.5 A1 + 2 (Stroke) Flange FV FX FZ L1 L2 M 52 9 9 80 92 108 18 8 60 91 61 11 11 99 116 134 20 10 77 104.5 70.
45
Compact Cylinder: Standard Single Acting, Single Rod Standard Series CQ2 ø12, ø16, ø20, ø25, ø32, ø40, ø50 How to Order 10 S CQ2 B 32 10 S Z CDQ2 B 32 10 S Z L W M9BW Long Stroke With auto switch (Built-in magnet) — L Bore size 12 mm 16 mm 20 mm 25 mm 32 mm 40 mm 50 mm — S n ∗ Mounting bolt is shipped together only when the mounting bracket is “B”. ∗ For details about the mounting bolt sizes, refer to pages 49 and 52. ∗ Mounting bolt is shipped together.
Series CQ2 Specifications 12 Bore size (mm) 16 20 40 50 0.15 0.13 1.5 MPa Proof pressure 1.0 MPa Maximum operating pressure Minimum operating pressure (MPa) 0.25 0.25 0.18 0.18 0.17 Without auto switch: –10 to 70°C (No freezing) With auto switch: –10 to 60°C (No freezing) Ambient and fluid temperature Not required (Non-lube) Lubrication 50 to 500 mm/s Piston speed Allowable kinetic energy (J) 0.022 0.038 0.055 0.09 0.15 0.26 0.46 +1.
Compact Cylinder: Standard Single Acting, Single Rod Retaining Ring Installation/Removal Mounting Brackets/Part No. Series CQ2 Theoretical Output Caution 50 Single Acting, Spring Extend Bore size (mm) 12 16 20 25 32 40 50 Stroke (mm) 5 10 5 10 5 10 5 10 5 10 5 10 10 20 (N) Spring reaction force (N) Second First 2.9 11 2.8 9.7 3.9 20 3.9 20 5.3 27 5.9 27 9.8 29 9.
Series CQ2 Mounting Bolt for CQ2B/Without Auto Switch Mounting method: Mounting bolt for through-hole mounting of the CQ2B is available as an option. Refer to the following for ordering procedures. Order the actual number of bolts that will be used. Example) CQ-M3 x 25L 4 pcs.
Compact Cylinder: Standard Single Acting, Single Rod Series CQ2 Construction Spring extend Port size M5 x 0.8 Built-in one-touch fittings Rod end male thread Axial Piping Non-rotating Rod With boss on head side Long Stroke Large Bore Size Standard Spring return Component Parts Replacement Parts ∗ On spring extend (Type T), piston and piston rod are integrated (stainless steel).
Standard: Single Acting, Single Rod Series CDQ2 With Auto Switch Refer to the below pages for further information on auto switches. Auto switch proper mounting position and its mounting height Minimum stroke for auto switch mounting P.193 to 199 Operating range Auto switch mounting brackets/Part no.
Compact Cylinder: Standard Single Acting, Single Rod Series CQ2 Mounting Bolt for CDQ2B/With Auto Switch Standard Mounting method: Mounting bolt for through-hole mounting of the CDQ2B is available as an option. Refer to the following for ordering procedures. Order the actual number of bolts that will be used. Example) CQ-M3 x 35L 2 pcs. Spring extend Mounting bolt Mounting bolt 9 7.5 12.5 C 6.1 8 10.5 9.5 9 7.5 12.5 D Mounting bolt part no.
Series CQ2 Dimensions ø12 to ø25/Spring Return Without Auto Switch Both ends tapped: CQ2A R Both Ends Tapped Standard (Through-hole): CQ2B (mm) Bore size (mm) O1 R 12 16 20 25 M4 x 0.7 M4 x 0.7 M6 x 1.0 M6 x 1.0 7 7 10 10 H thread effective depth C 4 x øN through 8 x øO counterbore F M5 (Port size) Z øD øI L B A E R M O1 thread K M E With Boss on Head Side (mm) With boss on head side Bore size G (mm) øTh9 12 16 20 25 1.5 1.5 2 2 Th9 0 15–0.043 0 20–0.052 0 13–0.043 0 15–0.
Compact Cylinder: Standard Single Acting, Single Rod Series CQ2 LG XY YX LS A 4 x øLD LX LZ Bore size (mm) 12 16 20 25 Bore size (mm) 12 16 20 25 Rod end male thread L1 (mm) A B L L1 5st 40.3 41.8 46.2 49.7 10st 5st 10st 45.3 22 27 13.5 24 46.8 23.5 28.5 13.5 25.5 51.2 24.5 29.5 14.5 28.5 54.7 27.5 32.5 15 32.5 LT LX LY LZ X LD LG LH 4.5 4.5 6.6 6.6 2.8 2.8 4 4 17 19 24 26 LS 5st 10 11.5 12.5 12.5 10st 15 16.5 17.5 17.5 Y 2 34 29.5 44 8 4.5 2 38 33.5 48 8 5 3.2 48 42 62 9.
Compact Cylinder: Standard Single Acting, Single Rod Series CQ2 Double clevis: CQ2D øCB CT +0.4 CX +0.2 CZ –0.1 –0.3 L CU B CW CL A Rod end male thread L1 55 4xN Cap bolt øCD hole H10 Axis d9 RR Double Clevis Bore size (mm) 12 16 20 25 Bore size (mm) 12 16 20 25 (mm) A B 5st 10st 5st 10st 45.5 50.5 22 27 48 53 23.5 28.5 56 61 24.5 29.5 62.5 67.5 27.5 32.5 CX CZ L L1 CB CD 12 14 20 24 5 5 8 10 N CL 5st 10st 39.5 44.5 42 47 47 52 52.5 57.
Series CQ2 Dimensions ø12 to ø25/Spring Return With Auto Switch R Both Ends Tapped H thread effective depth C Standard (Through-hole): CDQ2B (mm) Bore size (mm) O1 R 12 16 20 25 M4 x 0.7 M4 x 0.7 M6 x 1.0 M6 x 1.
Compact Cylinder: Standard Single Acting, Single Rod Series CQ2 Foot: CDQ2L L B Special cap bolt Foot LT LH LY Bore size (mm) XY YX LX LZ LG LS A 4 x øLD Rod end male thread (mm) A B L L1 5st 51.3 53.8 58.2 59.7 10st 5st 10st 56.3 33 38 13.5 24 58.8 35.5 40.5 13.5 25.5 63.2 36.5 41.5 14.5 28.5 64.7 37.5 42.5 15 32.5 Bore size (mm) LT LX LY LZ X Y 12 16 20 25 2 2 3.2 3.2 34 38 48 52 29.5 33.5 42 46 44 48 62 66 8 8 9.2 10.7 4.5 5 5.8 5.8 12 16 20 25 LD LG LH 4.5 4.5 6.
Compact Cylinder: Standard Single Acting, Single Rod Series CQ2 12 14 20 24 5 5 8 10 5st 10st 50.5 55.5 54 59 59 64 62.5 67.5 Bore size (mm) CX CZ L L1 N RR 12 16 20 25 5 6.5 8 10 10 12 16 20 3.5 3.5 4.5 5 14 15.5 18.5 22.5 M4 x 0.7 M4 x 0.7 M6 x 1.0 M6 x 1.0 6 6 9 10 CT 4 4 5 5 CU CW 7 10 12 14 14 15 18 20 Large Bore Size CD Long Stroke CB Double clevis bracket material: Carbon steel Surface treatment: Nickel plated Non-rotating Rod L1 CX+0.4 +0.2 –0.1 CZ –0.
Series CQ2 Dimensions (In the case of without auto switches, the A, B, F and P dimensions will be only changed. Refer to the dimension table.) ø32 to ø50/Spring Return With Auto Switch Both ends tapped: CQ2A /CDQ2A R O1 thread Both Ends Tapped R Bore size (mm) 32 40 50 Standard (Through-hole): CQ2B/CDQ2B R O1 M6 x 1.0 10 M6 x 1.0 10 M8 x 1.
LY LH LT YX 4 x øLD LX LZ LG LS A A B With auto switch LS A 32 40 50 52.2 57.2 28 58.7 63.7 34.5 39.5 66.7 76.7 33 17 62.2 67.2 38 18.5 23.5 12 68.7 73.7 44.5 49.5 40.5 50.5 17.5 27.5 76.7 86.7 Bore size (mm) L L1 LD LG LH LX LT LY LZ X 32 40 50 Rod end male thread B LS 5st 10st 20st 5st 10st 20st 5st 10st 20st 5st 10st 20st 5st 10st 20st 5st 10st 20st 22 27 28.5 33.5 50.5 60.5 27.5 37.5 Y 17 38.5 6.6 4 30 57 3.2 57 71 11.2 5.8 17 38.5 6.6 4 33 64 3.2 64 78 11.
Compact Cylinder: Standard Single Acting, Single Rod Series CQ2 Double clevis: CQ2D/CDQ2D CT 4xN Cap bolt øCD hole H10 Axis d9 CX+0.4 +0.2 CZ –0.1 –0.3 L B CW CL A CU RR Rod end male thread Double Clevis (mm) Without auto switch Bore size (mm) A B With auto switch CL A B CL 5st 10st 20st 5st 10st 20st 5st 10st 20st 5st 10st 20st 5st 10st 20st 5st 10st 20st 32 40 50 65 70 73.5 78.5 90.5 100.5 28 33 34.5 39.5 40.5 50.5 55 60 80 83.5 88.5 76.5 86.
Series CQ2 Dimensions ø12 to ø25/Spring Extend Without Auto Switch Both ends tapped: CQ2A R O1 thread Both Ends Tapped R (mm) Bore size (mm) O1 R 12 16 20 25 M4 x 0.7 M4 x 0.7 M6 x 1.0 M6 x 1.0 7 7 10 10 Standard (Through-hole): CQ2B H thread effective depth C M5 x 0.8 (Port size) Q 4 x øN through 8 x øO counterbore L B E M Z øD øI K A M E With Boss on (mm) Head Side With boss on head side Bore size G (mm) øTh9 12 16 20 25 1.5 1.5 2 2 Th9 0 15–0.043 0 20–0.052 0 13–0.
Compact Cylinder: Standard Single Acting, Single Rod Series Foot: CQ2L L CQ2 Foot Special cap bolt LT LH LY B X Y Y X LS A LG 4 x øLD LX LZ Bore size LT (mm) 12 16 20 25 Rod end male thread (mm) A Bore size (mm) 5st 10st 12 45.3 55.3 16 46.8 56.8 20 51.2 61.2 25 54.7 64.7 B 5st 22 23.5 24.5 27.5 L 10st 27 28.5 29.5 32.5 LX LY LZ L1 5st 18.5 18.5 19.5 20 10st 23.5 23.5 24.5 25 X Y 5st 29 30.5 33.5 37.5 10st 34 35.5 38.5 42.5 LD LG LH 4.5 4.5 6.6 6.6 2.8 2.
Compact Cylinder: Standard Single Acting, Single Rod Series CQ2 øCD hole H10 Axis d9 +0.4 CX +0.2 –0.1 CZ –0.3 L B CL A CU CW Rod end male thread RR Double Clevis A Bore size (mm) 5st 10st 12 50.5 60.5 16 53 63 20 61 71 25 67.5 77.5 L Bore size (mm) 5st 10st 12 8.5 13.5 16 8.5 13.5 20 9.5 14.5 25 10 15 (mm) B 5st 22 23.5 24.5 27.5 10st 27 28.5 29.5 32.5 L1 5st 19 20.5 23.5 27.5 10st 24 25.5 28.5 32.5 CB CD 12 14 20 24 5 5 8 10 CL 5st 10st 44.5 54.5 47 57 52 62 57.5 67.5 N RR M4 x 0.
Series CQ2 Dimensions ø12 to ø25/Spring Extend With Auto Switch Both ends tapped: CDQ2A R R Both Ends Tapped O1 thread H thread effective depth C Standard (Through-hole): CDQ2B Auto switch EA (mm) Bore size (mm) O1 R 12 16 20 25 M4 x 0.7 M4 x 0.7 M6 x 1.0 M6 x 1.0 7 7 10 10 EB Minimum lead wire bending radius 10 S øD U M5 x 0.
Compact Cylinder: Standard Single Acting, Single Rod Foot LG YX 4 x øLD LX LZ LS A 10st 70.7 68.8 73.2 74.7 5st 37.4 35.5 36.5 37.5 L 10st 42.4 40.5 41.5 42.5 Bore size LT LX LY LZ (mm) 12 16 20 25 Rod end male thread 5st 60.7 58.8 63.2 64.7 B L1 5st 18.5 18.5 19.5 20 10st 23.5 23.5 24.5 25 X Y 5st 29 30.5 33.5 37.5 10st 34 35.5 38.5 42.5 LD LG LH 4.5 4.5 6.6 6.6 2.8 2.8 4 4 17 19 24 26 LS 5st 25.4 23.5 24.5 22.5 10st 30.4 28.5 29.5 27.5 2 34 29.5 44 8 4.5 2 38 33.5 48 8 5 3.
Compact Cylinder: Standard Single Acting, Single Rod Series CQ2 Double clevis: CDQ2D 2xN Cap bolt CT øCB øCD hole H10 Axis d9 +0.4 CX +0.2 CZ –0.1 –0.3 L B CL A CU CW Rod end male thread RR Double Clevis Bore size (mm) 12 16 20 25 Bore size (mm) 12 16 20 25 A 5st 65.9 65 73 77.5 10st 75.9 75 83 87.5 L 5st 8.5 8.5 9.5 10 (mm) B 10st 13.5 13.5 14.5 15 5st 37.4 35.5 36.5 37.5 10st 42.4 40.5 41.5 42.5 L1 5st 19 20.5 23.5 27.5 10st 24 25.5 28.5 32.5 CB CD CL 5st 5 59.
Series CQ2 Dimensions ø32 to ø50/Spring Extend With Auto Switch (In the case of without auto switches, the A, B, P and Q dimensions will be only changed. Refer to the dimension table.) Both ends tapped: CQ2A/CDQ2A O1 thread R Both Ends Tapped R Bore size (mm) 32 40 50 Standard (Through-hole): R O1 M6 x 1.0 10 M6 x 1.0 10 M8 x 1.
Compact Cylinder: Standard Single Acting, Single Rod Series CQ2 Foot: CQ2L/CDQ2L L Foot B Bore size (mm) LT LH LY Special cap bolt XY YX 4 x øLD LX LZ LG LS A A 10st 67.2 73.7 76.7 B 20st – – 96.7 5st 28 34.5 – 10st 33 39.5 40.5 LS 20st – – 50.5 5st 12 18.5 – 10st 17 23.5 17.5 A 20st – – 27.5 5st 67.2 73.7 – B 10st 77.2 83.7 86.7 20st – – 106.7 5st 38 44.5 – LS 20st – – 60.5 L L1 Bore size LD LG LH LT LX LY LZ X (mm) 5st 10st 20st 5st 10st 20st Y 32 40 50 5st 57.2 63.
Double clevis: CQ2D/CDQ2D 5st 60 68.5 – 10st 70 78.5 86.5 A 20st – – 106.5 5st 80 88.5 – 10st 90 98.5 110.5 B 20st – – 130.5 L1 L Bore size CD CT CU CW CX CZ (mm) 5st 10st 20st 5st 10st 20st 32 40 50 5st 38 44.5 – 10st 43 49.5 50.5 CL 20st – – 60.5 5st 70 78.5 – N RR 10 5 14 20 18 36 12 17 – 33.5 38.5 – M6 x 1.0 10 10 6 14 22 18 36 12 17 – 33.5 38.5 – M6 x 1.0 10 14 7 20 28 22 44 10st 80 88.5 96.5 20st – – 116.5 Long Stroke CL 20st – – 50.5 – 18 28 – 43.5 53.5 M8 x 1.
Compact Cylinder: Large Bore Size Double Acting, Single Rod Series CQ2 ø125, ø140, ø160, ø180, ø200 How to Order Without auto switch CQ2B 125 30 DC Z With auto switch CDQ2B 125 30 DC Z M9BW With auto switch Made to Order (Built-in magnet) Refer to the next page for details. Mounting B Through-hole/Both ends tapped common (Standard) ∗ Cylinder mounting bolts are not included. Order them Number of auto switches — separately referring to “Mounting Bolt for CQ2B” on page 73.
Compact Cylinder: Large Bore Size Double Acting, Single Rod Series CQ2 Specifications 140 160 180 200 Standard 125 Bore size (mm) Double acting, Single rod Action Air Fluid Proof pressure 1.5 MPa Maximum operating pressure 1.0 MPa 0.7 MPa Large Bore Size 0.05 MPa Minimum operating pressure Ambient and fluid temperature 1.05 MPa Without auto switch: –10 to 70°C (No freezing) With auto switch: –10 to 60°C (No freezing) Not required (Non-lube) 50 to 500 mm/s Piston speed 7.
Series CQ2 Theoretical Output OUT IN (N) Bore size (mm) Operating pressure (MPa) Operating direction 125 140 160 180 200 0.3 0.5 0.7 IN 3376 5627 7878 OUT 3682 6136 8590 IN 4313 7188 10063 OUT 4618 7697 10776 IN 5655 9425 13195 OUT 6032 10053 14074 IN 7257 12095 16933 OUT 7634 12724 17813 IN 9048 15080 21112 OUT 9425 15708 21991 Weight Without Auto Switch Bore size (mm) 125 140 160 180 200 (kg) 10 20 30 40 50 75 100 125 150 175 200 5.24 5.
Compact Cylinder: Large Bore Size Double Acting, Single Rod Series CQ2 Construction Standard Component Parts Replacement Parts/Seal Kit Bore size (mm) 125 140 160 180 200 Kit no. CQ2B125-PS CQ2B140-PS CQ2B160-PS CQ2B180-PS CQ2B200-PS Contents Non-rotating Rod Note Hard anodised Nickel plated Chromated Hard chrome plated Nickel plated Phosphate coated Kits include items !2, !3, !4 from the table. ∗ Seal kit includes !2, !3, !4. Order the seal kit, based on each bore size.
Series CQ2 Dimensions ø125 to ø160 The dimensions are the same with or without an auto switch. Standard (Through-hole): C쏔Q2B Auto switch Minimum lead wire bending radius 10 2 x P (Rc, NPT, G) (Port size) 25 øD 2.5 Note) E 2 x 4 x øOB counterbore depth RB (Also back cover) 4 x øN through Q M Q H thread effective depth C K With flat washer 4 pcs.
Compact Cylinder: Large Bore Size Double Acting, Single Rod Series CQ2 Dimensions ø180, ø200 The dimensions are the same with or without an auto switch. Auto switch Minimum lead wire bending radius 10 2 x Rc, NPT, G 1/2 29 (Port size) Standard 2 x 4 x ø31.5 counterbore depth 26 (Also back cover) 162 52 102 + Stroke 119 + Stroke Long Stroke 17 36 162 204 Width across flat 55 Note 1) In the case of 20 mm stroke or less, it would come with 2 x 4 x M22 x 2.5 through thread.
Compact Cylinder: Large Bore Size Double Acting, Double Rod Series CQ2W ø125, ø140, ø160, ø180, ø200 How to Order Without auto switch CQ2WB 125 30 DC Z With auto switch CDQ2WB 125 30 DC Z M9BW With auto switch (Built-in magnet) Made to Order Refer to the next page for details. Type W Double rod Number of auto switches — Mounting S n B Through-hole/Both ends tapped common (Standard) ∗ Cylinder mounting bolts are not included. Order them separately 2 pcs. 1 pc. “n” pcs.
Compact Cylinder: Large Bore Size Double Acting, Double Rod Series CQ2W Specifications 160 180 200 Standard 140 Double acting, Double rod Action Air Fluid Proof pressure 1.5 MPa Maximum operating pressure 1.0 MPa 0.7 MPa Large Bore Size 0.05 MPa Minimum operating pressure Ambient and fluid temperature 1.05 MPa Without auto switch: –10 to 70°C (No freezing) With auto switch: –10 to 60°C (No freezing) Not required (Non-lube) 50 to 500 mm/s Piston speed Allowable kinetic energy (J) 7.
Series CQ2W Retaining Ring Installation/Removal Theoretical Output Caution (N) 1. For installation and removal, use an appropriate pair of pliers (tool for installing a type C retaining ring). 2. Even if a proper plier (tool for installing a type C retaining ring) is used, it is likely to inflict damage to a human body or peripheral equipment, as a retaining ring may be flown out of the tip of a plier (tool for installing a type C retaining ring). Be much careful with the popping of a retaining ring.
Compact Cylinder: Large Bore Size Double Acting, Double Rod Series CQ2W Mounting Bolt for CQ2WB Example) CQ-M12 x 100L 4 pcs. 22.9 27.7 Mounting bolt part no. CQ-M12 x 100L x 110L x 120L x 130L x 140L x 165L x 190L CQ-M14 x 110L x 120L x 130L x 140L x 150L x 175L x 200L Cylinder model C쏔Q2WB180-10DCZ -20DCZ -30DCZ -40DCZ -50DCZ -75DCZ -100DCZ C쏔Q2WB200-10DCZ -20DCZ -30DCZ -40DCZ -50DCZ -75DCZ -100DCZ C D 125 135 145 155 165 190 215 135 145 155 165 175 200 225 36 39 Mounting bolt part no.
Series CQ2W Dimensions ø125 to ø160 The dimensions are the same with or without an auto switch. Standard (Through-hole): C쏔Q2WB Auto switch Minimum lead wire bending radius 10 Q Q 2 x H thread effective depth C (Also back cover) 2 x 4 x øOB counterbore depth RB (Also back cover) 2 x P (Rc, NPT, G) (Port size) E M 25 øD øD Width across flat K 2 x 4 x OA thread depth RA With flat washer Note 1) 4 pcs. L B + Stroke 4 x øN through-hole 2.
Compact Cylinder: Large Bore Size Double Acting, Double Rod Series CQ2W Dimensions ø180, ø200 The dimensions are the same with or without an auto switch. 162 102 + Stroke 17 Large Bore Size 36 2 x 4 x M22 x 2.5 thread depth 38 Note 1) With flat washer Note 2) 4 pcs. 204 162 1.5 17 + Stroke Note 1) In the case of 20 mm stroke or less, it would come with 2 x 4 x M22 x 2.5 through thread. Note 2) Be sure to use the attached flat washer for mounting cylinder with through-holes.
Compact Cylinder: Long Stroke Double Acting, Single Rod Series CQ2 ø32, ø40, ø50, ø63, ø80, ø100 How to Order Without auto switch CQ2 A 32 200 DC Z With auto switch CDQ2 A 32 200 DC Z M9BW With auto switch Number of auto switches (Built-in magnet) Mounting A L LC F G D — Both ends tapped Foot Compact foot Rod flange Head flange Double clevis Bore size 32 40 50 63 80 100 ∗ Mounting brackets are shipped together, (but not assembled).
Compact Cylinder: Long Stroke Double Acting, Single Rod Series CQ2 Specifications 40 50 63 Air Fluid Maximum operating pressure 1.0 MPa Minimum operating pressure 0.05 MPa Large Bore Size 1.5 MPa Proof pressure Without auto switch: –10 to 70°C (No freezing) With auto switch: –10 to 60°C (No freezing) Ambient and fluid temperature Not required (Non-lube) Lubrication 50 to 500 mm/s 0.91 1.54 2.71 4.54 Long Stroke 0.52 +1.
Series CQ2 Copper and Fluorine-free Series (For CRT Manufacturing Process) 20 Allowable Lateral Load at Rod End Stroke DC(M)Z C쏔Q2A Bore size Mounting Brackets/ Part No. Note 1) Compact Bore size Foot Foot Note 1) Flange (mm) 70 ø100 ø32, ø40, ø50, ø63 ø80, ø100 Copper and fluorine-free series Allowable lateral load at rod end W (N) 60 For preventing the influence of copper ions or halogen ions during CRT manufacturing processes, copper and fluorine materials are not used in the component parts.
Compact Cylinder: Long Stroke Double Acting, Single Rod Series CQ2 Construction Standard Built-in one-touch fittings Replacement Parts/Seal Kit Note Hard anodised Chromated Hard chrome plated Anodised Anodised Phosphate coated Bore size (mm) Kit no. Contents CQ2A32-L-PS CQ2A40-L-PS Kits include items CQ2A50-L-PS !4, !5, !6 from the CQ2A63-L-PS table. CQ2A80-L-PS CQ2A100-L-PS ∗ Seal kit includes !4, !5, !6. Order the seal kit, based on each bore size.
Series CQ2 Dimensions ø32 to ø50 The dimensions are the same with or without an auto switch. Both ends tapped: C쏔Q2A H thread effective depth C 2 x P (Rc, NPT, G) (Port size) Q Auto switch Q 8 x O thread effective depth R Z M E øD øTh9 Minimum lead wire bending radius 10 K M E W 5 B + Stroke L A + Stroke J Rod end male thread Width across flat B1 Rod End Male Thread MM Bore size (mm) 32 40 50 H1 C1 X (mm) B1 C1 H1 L1 MM X 22 20.5 8 38.5 M14 x 1.5 23.5 22 20.5 8 38.
Compact Cylinder: Long Stroke Double Acting, Single Rod Series CQ2 Special cap bolt Compact Foot B + Stroke Bore size A (mm) X Y X Y LS + Stroke A + Stroke LX LZ B L L1 LD LH LS LT LX LY LZ X Y 84.5 45.5 17 38.5 6.6 30 72.9 3.2 34 57 45 13.7 5.8 96.4 33 82.4 3.2 40 64 52 13.7 7 39 88.9 3.2 50 78 64 16.7 8 55 17 38.5 6.6 104.9 55.5 18 43.
Series CQ2 The dimensions are the same with or without an auto switch. Double clevis: C쏔Q2D CT 4xN Cap bolt øCD hole H10 Axis d9 Double Clevis Bore size (mm) 32 40 50 CX +0.4 +0.2 CZ L –0.1 –0.3 Rod end male thread B + Stroke CL + Stroke A + Stroke CU CW RR Bore size (mm) 32 40 50 A B (mm) CD CL CT CU CW CX CZ 92.5 45.5 10 104 55 10 115.5 55.5 14 82.5 5 14 20 18 36 94 6 14 22 18 36 101.5 7 20 28 22 44 L L1 N RR 17 38.5 M6 x 1.0 10 17 38.5 M6 x 1.
90
Series CQ2 Dimensions ø63 to ø100 The dimensions are the same with or without an auto switch. 2xP (Port size) Minimum lead wire bending radius 10 Auto switch Q Z øD øTh9 Q 8 x O thread effective depth R H thread effective depth C M E Both ends tapped: C쏔Q2A 5 L K M E W B + Stroke A + Stroke Rod end male thread J Width across flat B1 Rod End Male Thread MM Bore size (mm) 63 80 100 H1 C1 X (mm) B1 C1 H1 L1 27 26 11 43.5 M18 x 1.5 28.5 MM X 32 32.5 13 53.5 M22 x 1.
Compact Cylinder: Long Stroke Double Acting, Single Rod Series CQ2 The dimensions are the same with or without an auto switch. B + Stroke X Y 4 × øLD LX LZ LS + Stroke A + Stroke Rod end male thread Compact Foot (mm) Bore size (mm) A B L L1 LD LH LS LT LX LY LZ X 63 80 100 111.4 57 18 43.5 11 46 93.4 3.2 60 91.5 77 18.2 9 133 66 20 53.5 13 59 111 4.5 77 114 98 22.5 11 22 53.5 13 71 123.5 6 94 136 117 24 12.5 148.5 75.
Series CQ2 The dimensions are the same with or without an auto switch. Double clevis: C쏔Q2D CT 4xN Cap bolt øCD hole H10 Axis d9 Double Clevis Bore size (mm) 63 80 100 CX +0.4 +0.2 CZ L –0.1 –0.3 B + Stroke CL + Stroke A + Stroke Rod end male thread CU CW RR Bore size (mm) 63 80 100 (mm) A B CD CL CT CU CW CX CZ 119 57 14 105 8 20 30 22 44 142 66 18 124 10 27 38 28 56 164.5 75.5 22 142.5 13 31 45 32 64 L L1 18 43.5 N RR M10 x 1.5 14 20 53.5 M12 x 1.
Compact Cylinder: Non-rotating Rod Double Acting, Single Rod Standard Series CQ2K ø12, ø16, ø20, ø25, ø32, ø40, ø50, ø63 How to Order 30 D CQ2K B 32 30 D Z CDQ2K B 32 30 D Z M9BW Number of auto switches (Built-in magnet) Non-rotating rod Mounting — Auto switch — Without auto switch ∗ Refer to the below table for applicable auto switches. Auto switch mounting groove ∗ Mounting brackets are shipped together, (but not assembled). ∗ Cylinder mounting bolts are not included.
Series CQ2K Specifications 12 Bore size (mm) 16 20 25 50 63 1.5 MPa Proof pressure 1.0 MPa Maximum operating pressure Minimum operating pressure 0.07 MPa 0.05 MPa Without auto switch: –10 to 70°C (No freezing) With auto switch: –10 to 60°C (No freezing) Ambient and fluid temperature Not required (Non-lube) Lubrication 50 to 500 mm/s Piston speed Symbol 40 Air Fluid Non-rotating rod 32 Double acting, Single rod Action Allowable kinetic energy (J) 0.022 0.043 Note 1) 0.038 0.
Compact Cylinder: Non-rotating Rod Double Acting, Single Rod Retaining Ring Installation/Removal Mounting Brackets/Part No. Series CQ2K Theoretical Output Caution Note 1) When ordering a foot, and compact foot brackets, order 2 pieces per cylinder. Note 2) Parts belonging to each bracket are as follows. Foot, Compact foot, Flange: Body mounting bolts Double clevis: Clevis pin, Body mounting bolts, Type C retaining rings for axis 16 20 25 32 40 Mounting 1.
Series CQ2K Construction Standard (ø12 to ø32) Standard (ø40 to ø63) Built-in one-touch fittings With boss on head side Replacement Parts/Seal Kit Component Parts No.
Compact Cylinder: Non-rotating Rod Double Acting, Single Rod CQ2K Series Mounting Bolt for CQ2KB/Without Auto Switch CQ-M3 x 30L x 35L x 40L x 45L x 50L x 55L CQ-M3 x 30L x 35L x 40L x 45L x 50L x 55L CQ-M5 x 35L x 40L x 45L x 50L x 55L x 60L x 65L x 70L x 75L x 80L CQ-M5 x 40L x 45L x 50L x 55L x 60L x 65L x 70L x 75L x 80L x 85L CQ-M5 x 40L x 45L x 50L x 55L x 60L x 65L x 70L x 75L x 80L x 85L x 120L x 145L C' 6.5 5 9.5 6.5 10 D' Mounting bolt part no.
Non-rotating Rod: Double Acting, Single Rod Series CDQ2K With Auto Switch Refer to the below pages for further information on auto switches. Auto switch proper mounting position and its mounting height Minimum stroke for auto switch mounting P.193 to 199 Operating range Auto switch mounting brackets/Part no. Weight Weight Bore size (mm) 12 16 20 25 32 40 50 63 (g) Cylinder stroke (mm) Additional Weight Bore size (mm) Both ends tapped (g) 12 16 20 25 32 40 50 63 — — — — — 6 6 19 1.
Compact Cylinder: Non-rotating Rod Double Acting, Single Rod Series CQ2K Mounting Bolt for CDQ2KB/With Auto Switch 9.5 8.5 Cylinder model CDQ2KB32-40DZ -45DZ -50DZ -75DZ -100DZ CDQ2KB40-5DZ -10DZ -15DZ -20DZ -25DZ -30DZ -35DZ -40DZ -45DZ -50DZ -75DZ -100DZ CDQ2KB50-10DZ -15DZ -20DZ -25DZ -30DZ -35DZ -40DZ -45DZ -50DZ -75DZ -100DZ CDQ2KB63-10DZ -15DZ -20DZ -25DZ -30DZ -35DZ -40DZ -45DZ -50DZ -75DZ -100DZ C D 85 90 8.5 95 120 145 45 50 55 60 65 70 7.5 75 80 85 90 115 140 55 60 65 70 75 12.
Series CQ2K Dimensions ø12 to ø25/Without Auto Switch Standard (Through-hole): CQ2KB ø12, ø16 3.5 ø6.5 3.5 ø20, ø25 7 Q F ø9 5.5 2 x øN through H thread effective depth C (øD øI Piston rod cross section G L ) K E M øTh9 øD (K) 2 x M5 (Port size) B + Stroke M A + Stroke E With Boss on Head Side (mm) With boss on head side Bore size G (mm) øTh9 12 16 20 25 1.5 1.5 2 2 Th9 0 15–0.043 0 20–0.052 0 13–0.043 0 15–0.
Compact Cylinder: Non-rotating Rod Double Acting, Single Rod Series CQ2K Dimensions ø12 to ø25/With Auto Switch ø12, ø16 H thread effective depth C ø6.5 3.5 2 x øN through 8 8.
Series CQ2K Dimensions ø32/Without Auto Switch 5.5 ø9 7 M8 x 1.25 thread effective depth 13 2 x Rc, NPT, G 1/8 (2 x M5) Note 1) (Port size) 19 2 x ø5.5 through 7.5 (5.5) Note 1) (14) 45 14 34 6) 14 0 ø21 –0.052 (ø1 ø16 2 7 Piston rod cross section 34 B + Stroke A + Stroke 45 4.5 49.5 Note 1) ( ): Stroke 5 mm With boss on head side (mm) 0 ø21 –0.052 Stroke range (mm) 5 to 50 75, 100 A B 39 49 32 42 2 Rod end male thread Width across flat 22 M14 x 1.5 8 20.5 23.5 28.
Compact Cylinder: Non-rotating Rod Double Acting, Single Rod Series CQ2K Dimensions Standard ø32/With Auto Switch 7 2 x Rc, NPT, G 1/8 (Port size) Auto switch Minimum lead wire bending radius 10 19 M8 x 1.25 thread effective depth 13 2 x ø5.5 through ø16 Piston rod cross section 2 7 34 45 42 + Stroke 4.5 49.5 Axial Piping 49 + Stroke Non-rotating Rod 6) (14) 45 34 14 14 0 Long Stroke 7.5 (ø1 ø21 –0.052 Large Bore Size ø9 5.5 Anti-lateral Load 0 ø21 –0.
Series CQ2K Dimensions ø40 to ø63/With Auto Switch (In the case of without auto switches, the A and B dimensions will be only changed. Refer to the dimension table.) Both ends tapped: CDQ2KA O1 thread R Both Ends Tapped R Bore size (mm) (mm) O1 40 50 63 R M6 x 1.0 10 M8 x 1.25 14 M10 x 1.
Compact Cylinder: Non-rotating Rod Double Acting, Single Rod Foot 29.5 13.5 63.7 39.5 23.5 39.5 23.5 30.5 7.5 66.7 40.5 17.5 40.5 17.5 36 10 72.2 46 20 46 20 LY LZ X Y 40 4 33 64 64 78 11.2 7 50 5 39 79 78 95 14.7 8 63 5 46 95 91.5 113 16.2 9 L L1 LD 17 38.5 6.6 18 43.5 9 18 43.
Compact Cylinder: Non-rotating Rod Double Acting, Single Rod Series CQ2K Double clevis: CDQ2KD CT 4xN Cap bolt øCD hole H10 Axis d9 CU CX +0.4 +0.2 CZ L –0.1 –0.3 B + Stroke CW CL + Stroke A + Stroke Rod end male thread ∗ For details about the rod end nut and accessory brackets, refer to page 23. ∗ Double clevis pin and retaining rings are included.
Compact Cylinder: Non-rotating Rod Double Acting, Double Rod Standard Series CQ2KW ø12, ø16, ø20, ø25, ø32, ø40, ø50, ø63 How to Order 30 D CQ2KW B 32 30 D Z CDQ2KW B 32 30 D Z M9BW Number of auto switches With auto switch (Built-in magnet) — Mounting B Through-hole (Standard) ø12 to ø63 A Both ends tapped Foot L ø40 to ø63 Compact foot LC Flange F Bore size 12 16 20 25 ∗ Mounting brackets are shipped together 12 mm 16 mm 20 mm 25 mm 32 40 50 63 2 pcs. 1 pc. “n” pcs.
Series CQ2KW Specifications 12 Bore size (mm) 16 20 Action 25 32 40 50 63 Double acting, Double rod Fluid Air Proof pressure 1.5 MPa Maximum operating pressure 1.0 MPa Minimum operating pressure 0.07 MPa 0.05 MPa Without auto switch: –10 to 70°C (No freezing) With auto switch: –10 to 60°C (No freezing) Ambient and fluid temperature Not required (Non-lube) Lubrication 50 to 500 mm/s Symbol Piston speed Non-rotating rod, Double acting Allowable kinetic energy (J) 0.022 0.
Compact Cylinder: Non-rotating Rod Double Acting, Double Rod Retaining Ring Installation/Removal Mounting Brackets/Part No. Series CQ2KW Theoretical Output Caution 2. Using a non-rotating rod cylinder Avoid using the air cylinder in such a way that rotational torque would be applied to the piston rod. If rotational torque is applied, the non-rotating guide will deform, causing a loss of non-rotating accuracy. Use the below table as a guide for the allowable rotational torque ranges.
Series CQ2KW Construction Standard (ø12 to ø32) Standard (ø40 to ø63) Built-in one-touch fittings Rod end male thread Component Parts Replacement Parts/Seal Kit Description No.
Compact Cylinder: Non-rotating Rod Double Acting, Double Rod CQ2KW Series Mounting Bolt for CQ2KWB/Without Auto Switch Standard Non-rotating rod end mounting Mounting method: Mounting bolt for through-hole mounting of the CQ2KWB is available as an option. Refer to the following for ordering procedures. Order the actual number of bolts that will be used. Mounting bolt Mounting bolt Example) CQ-M3 x 40L 2 pcs. 8.5 11 7 12.5 13.5 D Mounting bolt part no.
Non-rotating Rod: Double Acting, Double Rod Series CDQ2KW With Auto Switch Refer to the below pages for further information on auto switches. Auto switch proper mounting position and its mounting height Minimum stroke for auto switch mounting P.193 to 199 Operating range Auto switch mounting brackets/Part no.
Compact Cylinder: Non-rotating Rod Double Acting, Double Rod Series CQ2KW Mounting Bolt for CDQ2KWB/With Auto Switch 6.1 7.5 11 10 7.5 D' 45 50 55 60 65 70 50 55 60 65 70 75 55 60 65 70 75 80 85 90 95 100 55 60 65 70 75 80 85 90 95 100 55 60 65 70 75 80 85 90 95 100 125 150 Mounting bolt part no.
CQ2KW Series Dimensions ø12 to ø32/Without Auto Switch Standard (Through-hole): CQ2KWB 2xP (Port size) F 2 x øN through 2 x H thread effective depth C (Also back cover) øD (øD ) øTh9 E M K1 øD Q 7 5.5 (K1) 3.5 3.5 ø12 to ø25 ø9 ø20, ø25 ø6.
Compact Cylinder: Non-rotating Rod Double Acting, Double Rod Series CQ2KW Dimensions ø12 to ø32/With Auto Switch ø20, ø25 ø6.5 ø12, ø16 3.5 15 H thread effective depth C 7 (Also back cover) 2 x øN through 8 ø9 8.5 Standard Standard (Through-hole): CDQ2KWB U (øD Piston rod cross section Long Stroke L + Stroke 2 x øN through B1 MM MM Rod end male thread H1 C1 X L1 H1 C1 X L1 + Stroke A1 + 2 (Stroke) Built-in one-touch fittings: ø32 A1 B1 C1 H1 12 16 20 25 32 65.4 72 83 92 106.
CQ2KW Series Dimensions ø40 to ø63/With Auto Switch (In the case of without auto switches, the A, B dimensions will be only changed. Refer to the dimension table.) Both ends tapped: CQ2KWA/CDQ2KWA R O1 thread Both Ends Tapped R O1 R 40 50 63 M6 x 1.0 M8 x 1.25 M10 x 1.
Compact Cylinder: Non-rotating Rod Double Acting, Double Rod Series CQ2KW L + Stroke LG Special cap bolt 4 x øLD LX LZ LS + Stroke A + 2 (Stroke) Rod end male thread Rod End Male Thread L1 40 50 63 L1 + Stroke Without auto switch With auto switch A1 A1 117 127.5 129 127 137.5 139 (mm) L1 38.5 43.5 43.5 Non-rotating Rod Bore size (mm) A1 + 2 (Stroke) Foot 63 B LS 5 to 50 74 40 24 75, 100 84 50 34 10 to 50 76.5 40.5 17.5 75, 100 86.5 50.5 27.
Series CQ2KW M FV Flange: CQ2KWF/CDQ2KWF FX FZ FT L1 B + Stroke A + 2 (Stroke) L2 + Stroke 4 x øFD Rod End Male Thread Rod end male thread Bore size (mm) 40 50 63 L3 L4 + Stroke A1 + 2 (Stroke) Flange Bore size (mm) 40 50 63 For auto switch proper mounting position and its mounting height, refer to pages 169 to 175. Stroke range Without auto switch With auto switch (mm) A B A B 5 to 50 64 40 75, 100 74 50 10 to 50 66.5 40.5 75, 100 76.5 50.
120
Compact Cylinder: Axial Piping Double Acting, Single Rod Series CQP2 ø12, ø16, ø20, ø25, ø32, ø40, ø50, ø63, ø80, ø100 How to Order Without auto switch CQP2B 50 30 D With auto switch CDQP2B 50 30 D M9BW With auto switch (Built-in magnet) Made to Order Axial piping Refer to the next page for details. Mounting Number of auto switches B Through-hole — ∗ Cylinder mounting bolts are not included. Order them separately referring to “Mounting Bolt for C(D)QP2B” on pages 124 and 127.
Compact Cylinder: Axial Piping Double Acting, Single Rod Series CQP2 Specifications 12 Bore size (mm) 16 20 Action 25 32 Fluid 80 100 1.0 MPa 0.07 MPa Large Bore Size Minimum operating pressure 0.05 MPa Without auto switch: –10 to 70°C (No freezing) With auto switch: –10 to 60°C (No freezing) Ambient and fluid temperature Lubrication Not required (Non-lube) Piston speed Note) Stroke length tolerance does not include the amount of bumper change.
Series CQP2 Retaining Ring Installation/Removal Type 2. Even if a proper plier (tool for installing a type C retaining ring) is used, it is likely to inflict damage to a human body or peripheral equipment, as a retaining ring may be flown out of the tip of a plier (tool for installing a type C retaining ring). Be much careful with the popping of a retaining ring. Besides, be certain that a retaining ring is placed firmly into the groove of rod cover before supplying air at the time of installment.
Compact Cylinder: Axial Piping Double Acting, Single Rod Series CQP2 Mounting Bolt for CQP2B/Without Auto Switch 9.5 Standard Large Bore Size Long Stroke Cylinder model C D Mounting bolt part no. 50 CQ-M8 x 50L CQP2B63-10D 55 x 55L -15D 60 x 60L -20D 65 x 65L -25D 70 x 70L -30D x 75L -35D 14.
Series CQP2 Construction Standard A B A B e !3 t !1 !0 r !4 y q !2 w A-A section (Port on rod end) B-B section (Port on head end) o i u Rod end male thread Component Parts Replacement Parts/Seal Kit Description No.
Axial Piping: Double Acting, Single Rod Series CDQP2 Standard With Auto Switch Refer to the below pages for further information on auto switches. Auto switch proper mounting position and its mountig height Minimum stroke for auto switch mounting P.141 to 145 Operating range Large Bore Size Auto switch mounting brackets/Part no. Additional Weight (g) Bore size (mm) 12 Male thread 1.
Series CQP2 Mounting Bolt for CDQP2B/With Auto Switch Mounting method: Mounting bolt for through-hole mounting of the CDQP2B is available as an option. Refer to the following for ordering procedures. Order the actual number of bolts that will be used. Mounting bolt Example) CQ-M3 x 35L 2 pcs. Material: Chromium molybdenum steel Surface treatment: Zinc chromated Cylinder model C CDQP2B12-5D -10D -15D 5.5 -20D -25D -30D CDQP2B16-5D -10D -15D 8 -20D -25D -30D CDQP2B20-5D -10D -15D -20D -25D 10.
Compact Cylinder: Axial Piping Double Acting, Single Rod Series CQP2 Dimensions ø12 to ø100/Without Auto Switch 6.3 M H thread effective depth C F E B + Stroke L 4.5 2 x øN through 4 x øO counterbore Plug K A + Stroke Large Bore Size E1 øD W E2 øI Standard ø12 to ø25 2 x M5 x 0.8 (Port size) Rod End Male Thread MM H1 C1 X L1 (mm) Bore size (mm) B1 C1 H1 L1 MM X 12 16 20 25 8 10 13 17 9 10 12 15 4 5 5 6 14 15.5 18.5 22.5 M5 x 0.8 M6 x 1.0 M8 x 1.25 M10 x 1.25 10.
Series CQP2 Dimensions ø12 to ø100/With Auto Switch Auto switch Minimum lead wire bending radius 10 ø12 to ø25 25 H thread effective depth C 12.5 S E1 øD W E2 øI ≈U 6.3 M F E B + Stroke A + Stroke L 4.5 2 x øN through 4 x øO counterbore 2 x M5 x 0.8 (Port size) Plug K Width across flat B1 Rod end male thread MM Rod End Male Thread Standard Bore size (mm) Stroke range (mm) 12 16 20 25 5 to 30 5 to 30 5 to 50 5 to 50 A B 31.5 28 34 30.5 36 31.5 37.5 32.
Compact Cylinder: Axial Piping Single Acting, Single Rod Standard Series CQP2 ø12, ø16, ø20, ø25, ø32, ø40, ø50 CQP2B 50 10 T With auto switch CDQP2B 50 10 T M9BW With auto switch Made to Order (Built-in magnet) Refer to the next page for details. Axial piping Number of auto switches Through-hole — Bore size Order them separately referring to “Mounting Bolt for C(D)QP2B” on pages 132 and 135.
Series CQP2 Specifications 12 Bore size (mm) 16 20 25 0.15 0.13 1.0 MPa Maximum operating pressure Minimum operating pressure (MPa) 0.25 0.25 0.18 0.18 0.17 Without auto switch: –10 to 70°C (No freezing) With auto switch: –10 to 60°C (No freezing) Ambient and fluid temperature Not required (Non-lube) Lubrication 50 to 500 mm/s Piston speed Single acting, Spring extend 50 1.
Compact Cylinder: Axial Piping Single Acting, Single Rod Weight 79 142 205 126 224 323 211 372 533 338 589 841 535 928 1316 14 31 48 24 54 85 71 118 165 113 189 264 181 302 422 317 528 739 495 825 1150 Mounting Bolt for CQP2B/Without Auto Switch Mounting method: Mounting bolt for through-hole mounting of the CQP2B is available as an option. Refer to the following for ordering procedures. Order the actual number of bolts that will be used. Example) CQ-M3 x 25L 2 pcs.
Series CQP2 Construction Spring return A B A B A-A section (Port on rod side) B-B section (Port on head side) Port size M5 Spring extend A-A section (Port on rod side) Rod end male thread B-B section (Port on head side) Component Parts Description No.
Axial Piping: Single Acting, Single Rod Series CDQP2 Standard With Auto Switch Refer to the below pages for further information on auto switches. Auto switch proper mounting position and its mounting height Minimum stroke for auto switch mounting P.
Series CQP2 Mounting Bolt for CDQP2B/With Auto Switch Mounting method: Mounting bolt for through-hole mounting of the CDQP2B is available as an option. Refer to the following for ordering procedures. Order the actual number of bolts that will be used. Example) CQ-M3 x 35L 2 pcs.
Compact Cylinder: Axial Piping Single Acting, Single Rod Series CQP2 Dimensions ø12 to ø50/ Spring Return Without Auto Switch F E B A K Plug M5 x 0.8 (Port size) Rod end male thread Width across flat B1 Rod End Male Thread MM B1 C1 H1 L1 MM X 12 16 20 25 8 10 13 17 9 10 12 15 4 5 5 6 14 15.5 18.5 22.5 M5 x 0.8 M6 x 1.0 M8 x 1.25 M10 x 1.25 10.5 12 14 17.5 H1 C1 X L1 Standard 12 16 20 25 (mm) A B 5st 10st 5st 10st 25.5 30.5 22 27 27 32 23.5 28.5 29 34 24.5 29.5 32.5 37.5 27.
CQP2 Series Dimensions ø12 to ø50/ Spring Return With Auto Switch Auto switch Minimum lead wire bending radius 10 ø12 to ø25 25 H thread effective depth C 12.5 S E1 øD W E2 øI ≈U 6.3 M 2 x øN through 4 x øO counterbore L 4.5 F E B A M5 x 0.8 (Port size) Rod end male thread Width across flat B1 Rod End Male Thread MM Standard A B 5st 10st 5st 10st 36.5 41.5 33 38 39 44 35.5 40.5 41 46 36.5 41.5 42.5 47.5 37.5 42.
Compact Cylinder: Axial Piping Single Acting, Single Rod Series CQP2 Dimensions ø12 to ø50/ Spring Extend Without Auto Switch 6.3 H thread effective depth C F M5 x 0.8 (Port size) L 4.5 2 x øN through 4 x øO counterbore B E Rod end male thread K A Width across flat B1 Plug Rod End Male Thread MM Bore size (mm) B1 C1 H1 12 16 20 25 8 10 13 17 9 10 12 15 4 5 5 6 H1 C1 X (mm) L1 5st 19 20.5 23.5 27.5 10st 24 25.5 28.5 32.5 MM X M5 x 0.8 M6 x 1.0 M8 x 1.25 M10 x 1.25 10.
Series CQP2 Dimensions ø12 to ø50/ Spring Extend With Auto Switch ø12 to ø25 Auto switch Minimum lead wire bending radius 10 12.5 S E1 øD W E2 øI 25 H thread effective depth C ≈U 6.3 M 2 x øN through 4 x øO counterbore L 4.5 F B E M5 x 0.8 (Port size) Rod end male thread Plug K A Width across flat B1 MM Rod End Male Thread Bore size (mm) B1 C1 H1 12 16 20 25 8 10 13 17 9 10 12 15 4 5 5 6 M N O 22 28 36 40 3.5 6.5 depth 3.5 3.5 6.5 depth 3.5 5.5 9 depth 7 5.
140 Made to Order Auto Switch With Auto Switch Water Resistant With End Lock Anti-lateral Load Axial Piping Non-rotating Rod Long Stroke Large Bore Size Standard
Axial Piping Series CDQP2 With Auto Switch 1 1 Auto Switch Proper Mounting Position (Detection at Stroke End) and its Mounting Height Applicable Cylinder Series: CDQP2, CDQP2쏔쏔쏔-쏔S/-쏔T (Axial piping) ø12 to ø25 D-A9쏔 D-M9쏔 D-M9쏔W D-M9쏔AL D-A9쏔V D-M9쏔V D-M9쏔WV D-M9쏔AVL 25 U A B U ø32 to ø100 A 25 D-F7NTL D-F7BAL D-A73C D-A80C D-J79C D-A79W D-F7쏔WV D-F7쏔V D-F7BAVL ø12 to ø25 U A D-P4DWL B A ø40 to ø100 U 141 ø32 to ø100 U D-A7쏔 D-A80 D-A7쏔H D-A80H D-F7쏔 D-J79 D-F7쏔W D-J79W D-F79F B A
Series CDQP2 Standard Compact Cylinder: Axial Piping Auto Switch Proper Mounting Position Applicable Cylinder Series: CDQP2 (Axial piping) 12 16 20 25 32 40 50 63 80 100 D-F7NT Large Bore Size D-A73 D-A80 D-P4DW D-A79W A B A B A B A B A B A B A B 2 5 5 5.5 6.5 10.5 8.5 11 14 18.5 3 2.5 3.5 4 3.5 6 9 12 16.5 21.5 6 9 9 9.5 10.5 14.5 12.5 15 18 22.5 7 6.5 7.5 8 7.5 10 13 16 20.5 25.5 4.5 7.5 7.5 7.5 9 13 11 13.5 17.5 21 5.5 5 6.5 7 6 8.5 11.5 14.5 18 24 5 8 8 8 9.5 13.5 11.
Axial Piping Series CDQP2 With Auto Switch 2 2 Minimum Stroke for Auto Switch Mounting Applicable Cylinder Series: CDQP2, CDQP2쏔쏔쏔-쏔S/-쏔T (Axial piping) D-A9쏔V D-A7쏔 D-A80 D-A73C D-A80C D-A9쏔 D-M9쏔WV D-M9쏔AVL D-F7쏔WV D-F7BAVL 5 5 10 10 5 10 10 15 Number of auto switches D-M9쏔V D-F7쏔V D-J79C With 1 pc. With 2 pcs.
Series CDQP2 Standard Compact Cylinder: Axial Piping 4 Auto Switch Mounting Brackets/Part No. Applicable Cylinder Series: CDQP2, CDQP2쏔쏔쏔-쏔S/-쏔T (Axial piping) Bore size (mm) ø32 to ø100 Large Bore Size ø12, ø16, ø20, ø25 C A Long Stroke Auto switch mounting surface B Auto switch mounting surface Auto switch mounting rail side only A/B/C side BQ-1 BQ2-012 Two kinds of auto switch brackets are used as a set. BQ-2 BQ2-012 Two kinds of auto switch brackets are used as a set.
Axial Piping Series CDQP2 With Auto Switch 3 Other than the applicable auto switches listed in “How to Order”, the following auto switches are mountable. Refer to Best Pneumatics No. 2 for detailed specifications.
Compact Cylinder: Anti-lateral Load Standard Series CQ2 ø32, ø40, ø50, ø63, ø80, ø100 30 D C Z With auto switch CDQ2 B S 32 30 D C Z M9BW With auto switch Made to Order (Built-in magnet) Refer to the next page for details. Mounting Number of auto switches Type S — Anti-lateral load S n Bore size 32 40 50 63 80 100 ∗ Mounting brackets are shipped together, (but not assembled). ∗ Cylinder mounting bolts are not included.
Series CQ2 Specifications 32 Bore size (mm) 40 50 Action 63 80 100 Double acting, Single rod Fluid Air Proof pressure 1.5 MPa Maximum operating pressure 1.0 MPa Minimum operating pressure 0.05 MPa Without auto switch: –10 to 70°C (No freezing) With auto switch: –10 to 60°C (No freezing) Ambient and fluid temperature Lubrication Not required (Non-lube) Symbol Piston speed Double acting, Single rod Allowable kinetic energy (J) 50 to 500 mm/s 0.29 0.52 0.91 1.54 2.71 4.54 +1.
Compact Cylinder: Anti-lateral Load Series CQ2 Copper and Fluorine-free Series (For CRT Manufacturing Process) Allowable Lateral Load at Rod End 20-CQ2BS Without Auto Switch With Auto Switch Specifications 32 Bore size (mm) Action Proof pressure Max. operating pressure Rubber bumper Piping Piston speed Mounting Auto switch 40 50 63 80 100 Double acting, Single rod 1.5 MPa 1.
Series CQ2 Construction Standard Rod end male thread Component Parts No.
Anti-lateral Load Series CDQ2 Standard With Auto Switch Refer to the below pages for further information on auto switches. Auto switch proper mounting position and its mounting height Minimum stroke for auto switch mounting P.
Series CQ2 Mounting Bolt for CQ2BS/Without Auto Switch Mounting method: Mounting bolt for through-hole mounting of the CQ2BS is available as an option. Refer to the following for ordering procedures. Order the actual number of bolts that will be used. Mounting bolt Example) CQ-M5 x 40L 4 pcs.
Compact Cylinder: Anti-lateral Load Series CQ2 12.5 14.5 15 15.5 Mounting bolt part no.
Series CQ2 Dimensions ø32 to ø50/With Auto Switch (In the case of without auto switches, the A, B dimensions will be only changed. Refer to the dimension table.) Standard (Through-hole): CQ2BS/CDQ2BS Both ends tapped: CQ2AS/CDQ2AS CDQ2AS O1 thread Both Ends Tapped R R 32 40 50 Auto switch Minimum lead wire bending radius 10 M6 x 1.0 10 M6 x 1.0 10 M8 x 1.
Compact Cylinder: Anti-lateral Load YX LG LS + Stroke LX LZ 4 x øLD 50 Bore size (mm) A + Stroke Rod end male thread 40 50 LD 17 38.5 6.6 17 38.5 6.6 18 43.5 9 LZ X Y 57 71 11.2 5.8 64 64 78 11.2 7 79 78 95 14.7 8 LS 33 43 39.5 49.5 40.5 50.5 17 67.2 43 27 27 23.5 73.7 49.5 33.5 33.5 17.5 76.7 50.5 27.5 27.5 Stroke range (mm) LG LH LT LX LY 4 30 3.2 57 4 33 3.2 5 39 3.
Series CQ2 Double clevis: CQ2DS/CDQ2DS CT 4xN Cap bolt øCD hole H10 Axis d9 CX+0.4 +0.2 CZ –0.1 –0.3 L B + Stroke CW CL + Stroke A + Stroke CU RR Double Clevis Bore size (mm) 32 40 50 Bore size (mm) 32 40 L1 50 (mm) Stroke range Without auto switch With auto switch (mm) A B CL A B CL 5 to 50 70 33 60 80 43 70 75, 100 80 43 70 5 to 50 78.5 39.5 68.5 88.5 49.5 78.5 75, 100 88.5 49.5 78.5 10 to 50 90.5 40.5 76.5 100.5 50.5 86.5 100.5 50.5 86.
Series CQ2 Dimensions ø63 to ø100/With Auto Switch Standard (Through-hole): CQ2BS/CDQ2BS (In the case of without auto switches, the A, B dimensions will be only changed. Refer to the dimension table.) Both ends tapped: CQ2AS/CDQ2AS Both Ends Tapped The dimensions with boss on head side are equivalent to those of the CQ2 series, double acting, single rod. Refer to page 19.
Series CQ2 Foot Foot: CQ2LS/CDQ2LS L B + Stroke Bore size (mm) LY 63 XY LT LH Special cap bolt YX LG LS + Stroke 80 100 LX LZ 4 x øLD Bore size (mm) A + Stroke 63 80 100 L1 LY LT LH Special cap bolt X X Y 4 × øLD LX LZ LS + Stroke A + Stroke Stroke range (mm) 10 to 50 75, 100 10 to 50 75, 100 10 to 50 75, 100 A B With auto switch LS A B LS 72.2 46 20 82.2 56 30 82.2 56 30 85 53.5 23.5 95 63.5 33.5 95 63.5 33.5 98 63 29 108 73 39 108 73 39 L L1 LD 18 43.5 11 20 53.
Compact Cylinder: Anti-lateral Load Series CQ2 80 100 Bore size (mm) 63 80 100 CD CT CU L L1 N RR 30 22 44 8 33.5 M10 x 1.5 14 38 28 56 10 43.5 M12 x 1.75 18 45 32 64 12 43.5 M12 x 1.75 22 8 20 10 27 13 31 Double clevis bracket material: Cast iron Surface treatment: Painted ∗ For details about the rod end nut and accessory brackets, refer to page 23. ∗ Double clevis pin and retaining rings are included.
159
Compact Cylinder: With End Lock Standard Series CBQ2 ø20, ø25, ø32, ø40, ø50, ø63, ø80, ø100 CBQ2 B 40 30 D C H N With auto switch CDBQ2 B 40 30 D C H N M9BW With auto switch Number of auto switches (Built-in magnet) ø20, ø25 ø32 to ø100 Mounting Through-hole/Both ends B tapped B Through-hole (Standard) Note 2) common (Standard) Foot Both ends tapped L A Compact foot Foot LC L Rod flange Compact foot F LC Head flange Rod flange G F Double clevis Head flange D G Note 1) Mounting brackets are D
Series CBQ2 Specifications 20 Bore size (mm) 25 32 Action 40 50 63 80 100 'RXEOH DFWLQJ 6LQJOH URG Fluid $LU Proof pressure 03D Maximum operating pressure 03D Minimum operating pressure 03D Note) Without auto switch: –10 to 70°C (No freezing) With auto switch: –10 to 60°C (No freezing) Ambient and fluid temperature Lubrication 1RW UHTXLUHG 1RQ OXEH Piston speed WR PP V Allowable kinetic energy (J) 0.055 0.09 0.15 0.26 0.46 0.77 1.36 2.27 3450 5390 +1.
Compact Cylinder: With End Lock CBQ2 Allowable Lateral Load at Rod End 0.5 MPa 0.4 MPa With Rubber Bumper With Auto Switch Standard Allowable Kinetic Energy Series 200 300 ø25 1 ø20 0.
Series CBQ2 Mounting Bolt for CBQ2 Mounting method: Mounting bolt for through-hole mounting of the C(D)BQ2 is available as an option. Refer to the following for ordering procedures. Order the actual number of bolts that will be used. Mounting bolt Example) CQ-M5 x 75L 4 pcs. Note) Be sure to use the attached flat washers when mounting ø20 and ø25 cylinders with through-holes.
Compact Cylinder: With End Lock Series CBQ2 Construction Large Bore Size Standard ø32 to ø63 Long Stroke Manual release (Lock type): Suffix L Head end lock Non-rotating Rod Cylinder tube form ø32 to ø63 Rod end lock Cylinder tube form ø80 or more ø80, 100 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23A 23B No.
Series CBQ2 Dimensions ø20, ø25 Standard (Through-hole/Both ends tapped common): CBQ2B/CDBQ2B End lock mechanism With head end lock (Manual release lock type) DL End lock mechanism Manual release non-lock type ø15 2 x 4 x ø OB counterbore depth RB 24 ø11 H thread effective depth C 2 x 4 x OA effective depth RA 15 1 End Lock Mechanism Dimensions (mm) 20 21 28.5 40 21 21 29.5 41 HR Flat washer Bore size DL DM HR HN (mm) (Max.
Foot (mm) Standard B + Stroke L Special cap bolt LH LY Bore size Standard stroke With head end lock With rod end lock (mm) A B LS A B LS 20 LT 25 XY YX LS + Stroke A + Stroke LG LX LZ 4 x øLD Rod end male thread 10, 15, 20, 25 82.7 61 49 76.2 54.5 42.5 50, 75, 100 87.7 66 54 87.7 10, 15, 20, 25 86.2 64 49 79.7 57.5 42.5 50, 75, 100 91.2 69 54 91.2 Bore size Standard stroke L (mm) 20 25 66 54 69 54 L1 LD LG LH LT LX LY LZ X 10, 15, 20, 25 14.5 28.5 6.
Series CBQ2 Double clevis: CBQ2D/CDBQ2D Cap bolt øCD hole H10 Axis d9 Double Clevis Bore size Standard stroke (mm) 20 CT CX +0.4 +0.2 CZ –0.1 –0.3 L B + Stroke CW CL + Stroke A + Stroke CU RR 25 10, 15, 20, 25 50, 75, 100 (mm) With head end lock With rod end lock A B CL L L1 A B CL L L1 92.5 61 83.5 4.5 18.5 86 54.5 77 4.5 18.5 107.5 66 98.5 14.5 28.5 107.5 66 99 64 89 5 22.5 92.5 57.5 82.5 5 22.5 50, 75, 100 114 69 104 15 32.5 114 15 32.
Series CBQ2 Dimensions ø32 to ø100 Standard (Through-hole): Both Ends Tapped Both ends tapped: CBQ2A/CDBQ2A CBQ2B/CDBQ2B R1 O1 thread R1 With head end lock End lock mechanism With rod end lock R1 M6 x 1.0 M6 x 1.0 M8 x 1.25 M10 x 1.5 M12 x 1.75 M12 x 1.
Series CBQ2 Foot: CBQ2L/CDBQ2L Foot With head end lock With rod end lock Bore size Standard stroke (mm) A B LS A B LS B + Stroke Special cap bolt LT LH LY L XY Y X LS + Stroke (mm) LG LX LZ 4 x øLD A + Stroke 32 40 50 63 80 100 89.7 65.5 49.5 82.2 10, 15, 20, 25 50, 75, 100 38.5 6.6 17 38.5 6.6 101.7 75.5 52.5 91.7 65.5 42.5 18 43.5 9 103.2 18 43.5 11 20 53.5 13 22 53.5 13 X Y 32 40 50 63 80 100 59 77 51 97.2 71 45 25, 50 142.5 111 81 75, 100 147.
Compact Cylinder: With End Lock Series CBQ2 58 8 48 56 65 5.5 8 54 62 72 93.5 75.5 83.5 65.5 6.6 9 67 76 89 9 9 80 92 108 11 11 99 116 134 11 11 117 136 154 77 25, 50 131 111 123.5 103.5 75, 100 136 116 89 71 136 116 25, 50 142.5 120.5 135 113 75, 100 147.5 125.5 147.5 125.5 10, 15, 20, 25 50, 75, 100 25, 50, 75, 100 L L1 M 17 38.5 34 17 38.5 40 18 43.5 50 18 43.5 60 20 53.5 77 22 53.5 94 Non-rotating Rod 75 Long Stroke 5.5 81.5 64.
Series CBQ2 Dimensions ø32 to ø100 Head flange: CBQ2G/CDBQ2G Head Flange M FV FX FZ (mm) Bore size Standard stroke With head end lock (mm) A B L L1 4 x øFD L B + Stroke A + Stroke FT 32 40 50 63 80 Rod end male thread 100 80.5 65.5 10, 15, 20, 25 50, 75, 100 90 32 40 50 63 80 100 Rod end nut A B L L1 73 58 7 28.5 28.5 79.5 64.5 7 28.5 33.5 82.5 65.5 8 33.5 8 33.5 7 28.5 7 8 94 77 8 33.5 25, 50 132 111 10 43.5 124.5 103.5 10 43.5 75, 100 147 116 20 53.
Compact Cylinder: With End Lock Warning Operating Precautions Manual Release Caution 1. Do not use 3-position solenoid valves. Avoid use in combination with 3-position solenoid valves (especially closed center metal seal types). If pressure is trapped in the port on the lock mechanism side, the cylinder cannot be locked. Furthermore, even after being locked, the lock may be released after some time, due to air leaking from the solenoid valve and entering the cylinder. 2.
With End Lock Series CDBQ2 With Auto Switch 1 1 Auto Switch Proper Mounting Position (Detection at Stroke End) and its Mounting Height Applicable Cylinder Series: CDBQ2 (With end lock) D-A9 D-M9 D-M9 W D-M9 AL D-A9 V D-M9 V D-M9 WV D-M9 AVL ø20, ø25 A B U ø32 to ø100 A D-F7NTL D-F7BAL D-A73C D-A80C D-J79C D-A79W D-F7 WV D-F7 V D-F7BAVL ø32 to ø100 A D-P4DWL B ø40 to ø100 A 173 U U D-A7 D-A80 D-A7 H D-A80H D-F7 D-J79 D-F7 W D-J79W D-F79F B B U
Series CDBQ2 Standard Compact Cylinder: With End Lock Auto Switch Mounting Height Applicable Cylinder Series: CDBQ2 (With end lock) B A Large Bore Size B A B A B A B 35 (35) 10 (15) 39 (39) — — Long Stroke A 20 (Head end lock) — — — — — — 6 (11) 20 (Rod end lock) — — — — — — 31.5 (34) 3 (12) 35.5 (38) 7 (16) — — 25 (Head end lock) — — — — — — 8 (10) 37 (39) 12 (14) 41 (43) — — 25 (Rod end lock) — — — — — — 32 (35) 5.5 (14) 36 (39) 9.
With End Lock Series CDBQ2 With Auto Switch 2 2 Minimum Stroke for Auto Switch Mounting Applicable Cylinder Series: CDBQ2 (With end lock) (mm) D-A9 V D-A7 D-A80 D-A73C D-A80C D-A9 D-M9 WV D-M9 AVL D-F7 WV D-F7BAVL 5 5 10 10 5 10 10 15 Number of auto switches D-M9 V D-F7 V D-J79C With 1 pc. With 2 pcs.
Series CDBQ2 Standard Compact Cylinder: With End Lock 4 Auto Switch Mounting Brackets/Part No. Applicable Cylinder Series: CDBQ2 (With end lock) Auto switch mounting surface Bore size (mm) Port side Port side Port side C C A A B B B A/B/C side Non-rotating Rod Port/A/B/C side BQ-2 BQ2-012 Two kinds of auto switch brackets are used as a set. Set screw (Not used) Auto switch mounting brackets are not required. Axial Piping Auto switch mounting brackets are not required.
With End Lock Series CDBQ2 With Auto Switch 3 Other than the applicable auto switches listed in “How to Order”, the following auto switches are mountable. Refer to Best Pneumatics No. 2 for detailed specifications.
Compact Cylinder: Water Resistant Double Acting, Single Rod Standard Series CQ2 ø20, ø25, ø32, ø40, ø50, ø63, ø80, ø100 How to Order R 30 D CQ2 B 32 R 30 D Z CDQ2 B 32 R 30 D Z M9BA Mounting — B Through-hole (Standard) (ø20 to ø100) Both ends tapped A Foot L Compact foot LC (ø40 to ø100) Rod flange F Head flange G Double clevis D 2 pcs. 1 pc. “n” pcs. S n Made to Order Axial Piping Refer to the next page for details.
Series CQ2 Specifications 20 Bore size (mm) 25 32 Action 40 50 100 1.5 MPa Proof pressure Maximum operating pressure 1.0 MPa Minimum operating pressure 0.08 MPa Without auto switch: –10 to 70°C (No freezing) With auto switch: –10 to 60°C (No freezing) Ambient and fluid temperature Not required (Non-lube) Lubrication Double acting, Single rod 80 Air Fluid JIS Symbol 63 Double acting, Single rod 50 to 500 mm/s Piston speed 0.055 Allowable kinetic energy (J) 0.09 0.15 0.26 0.46 0.
Compact Cylinder: Water Resistant Double Acting, Single Rod 100 Mounting Brackets/Part No. Bore size (mm) 40 50 63 80 100 Foot Note 1) Compact Foot Note 1) CQ-L040 CQ-LC040 CQ-L050 CQ-LC050 CQ-L063 CQ-LC063 CQ-L080 CQ-LC080 CQ-L100 CQ-LC100 Flange Double clevis CQ-F040 CQ-D040 CQ-F050 CQ-D050 CQ-F063 CQ-D063 CQ-D080 CQ-F080 CQ-F100 CQ-D100 Note 1) When ordering a foot and compact foot brackets, order 2 pieces per cylinder. Note 2) Parts belonging to each bracket are as follows.
Series CQ2 Construction Standard (ø20 to ø32) Standard (ø40 to ø100) Replacement Parts/Seal Kit Component Parts Note Material Hard anodised Aluminum alloy Chromated Aluminum alloy ø20 to ø25 Stainless steel Piston rod ø32 to ø100, Hard chrome plated Carbon steel Rod cover ø20 to ø32, Anodised Aluminum alloy Collar ø40 to ø100, Anodised Aluminum alloy Retaining ring Carbon tool steel ø40 to ø100, Phosphate coated Oil-impregnated sintered alloy ø20, ø25 Bushing Bearing alloy ø32 to ø100 Hexagon socket head
Water Resistant: Double Acting, Single Rod Series CDQ2 Weight 25 30 35 40 45 50 75 100 ø20 130 142 155 167 179 191 204 216 228 240 — — ø25 182 197 213 228 244 259 275 290 306 320 — — ø32 263 284 305 327 348 369 390 412 433 454 561 668 ø40 293 315 336 358 379 401 422 444 465 487 598 710 ø50 — 489 522 555 588 620 653 687 720 753 925 1097 ø63 — 700 738 776 814 852 890 928 966 1004 1201 1397 ø80 — 1219 1279 1340 1400 1460 1520 1581 1641 1701 1998 2295 ø100 — 2061 2142 2222 2302
Series CQ2 Construction ø20, ø25 ø32 Replacement Parts/Seal Kit Component Parts Material Note Aluminum alloy Hard anodised 1 Aluminum alloy Chromated 2 Stainless steel ø20 to ø25 3 Piston rod Carbon steel ø32 to ø100, Hard chrome plated Aluminum alloy ø20 to ø32, Anodised 4 Rod cover Aluminum alloy ø40 to ø100, Anodised 5 Collar Carbon tool steel Phosphate coated 6 Retaining ring Oil-impregnated sintered alloy ø20, ø25 7 Bushing Bearing alloy ø32 to ø100 8 Hexagon socket head cap screw Chromium molybde
Compact Cylinder: Water Resistant Double Acting, Single Rod Series CQ2 Dimensions Standard (Through-hole): CQ2B Q 2 x ø5.5 through 2 x 2 x ø9 counterbore depth 7 H thread effective depth C 5.5 Large Bore Size 2 x M5 (Port size) Long Stroke 2.
Series CQ2 Dimensions ø20, ø25/With Auto Switch Standard (Through-hole): CDQ2B Auto switch 13.6 6.8 H thread effective depth C S øT øD U Minimum lead wire bending radius 10 Q 2.7 2 x M5 x 0.8 (Port size) 5.5 B + Stroke L 2 x ø5.
Compact Cylinder: Water Resistant Double Acting, Single Rod Series CQ2 Dimensions ø32/With Auto Switch Minimum lead wire bending radius 10 Auto switch Long Stroke 14 45 2 x ø5.5 through 2 x 2 x ø9 counterbore depth 7 2 x P (2 x M5 x 0.8) Note) (Port size) 2.7 14 34 B + Stroke 12 45 A + Stroke 4.5 49.5 Rod end male thread Note) ( ): Without auto switch, 5 mm strokes Axial Piping M14 x 1.5 Non-rotating Rod M8 x 1.25 thread effective depth 13 ø22.1 ø16 7.5 (5.
Series CQ2 Dimensions ø40, ø50/With Auto Switch (In the case of without auto switches, the A, B dimensions will be only changed. Refer to the dimension table.) Both ends tapped: CQ2A/CDQ2A O1 thread R (mm) Bore size (mm) O1 R 40 50 M6 x 1.0 M8 x 1.
Compact Cylinder: Water Resistant Double Acting, Single Rod Foot LH Special cap bolt YX LT XY LG LS + Stroke 4 x øLD LX LZ A + Stroke Rod end male thread Bore size (mm) LG Without auto switch With auto switch A 53.7 63.7 56.7 66.7 B LS A B LS 29.5 13.5 63.7 39.5 23.5 39.5 23.5 30.5 7.5 66.7 40.5 17.5 40.5 17.5 LH LT LX LY LZ X Y 40 4 33 3.2 64 64 78 11.2 7 50 5 39 3.2 79 78 95 14.7 8 L L1 LD 17 38.5 6.6 18 43.
Series CQ2 Double clevis: CQ2D/CDQ2D 4xN Cap bolt CT CX +0.4 +0.2 CZ L –0.1 –0.3 B + Stroke CL + Stroke A + Stroke Rod end male thread øCD hole H10 Axis d9 CW CU RR Double Clevis Bore size Stroke range (mm) (mm) 5 to 50 40 75, 100 10 to 50 50 75, 100 Bore size CW (mm) (mm) Without auto switch With auto switch A B 78.5 88.5 90.5 100.5 29.5 39.5 30.5 40.5 CL A B CL CX CZ L L1 N RR 68.5 88.5 39.5 78.5 78.5 76.5 100.5 40.5 86.5 86.5 40 22 18 36 17 38.5 M6 x 1.
Series CQ2 Dimensions ø63 to ø100/With Auto Switch (In the case of without auto switches, the A, B dimensions will be only changed. Refer to the dimension table.) Both ends tapped: CQ2A/CDQ2A R O1 thread Both Ends Tapped R (mm) Bore size (mm) O1 R 63 80 100 M10 x 1.5 M12 x 1.75 M12 x 1.
Series CQ2 Foot: CQ2L/CDQ2L XY LT LH Special cap bolt FV M B + Stroke LY L Head flange: CQ2G/CDQ2G YX LG LS + Stroke 4 x øLD LX LZ L FX FZ B + Stroke FT A + Stroke A + Stroke 4 x øFD Rod end male thread Rod end male thread L1 L1 Compact foot: CQ2LC/CDQ2LC Compact Foot L B + Stroke LT LH LY Special cap bolt Y X X LS + Stroke A + Stroke Rod end male thread Y LX LZ 4 × øLD Bore size Stroke range (mm) (mm) 10 to 50 63 75, 100 10 to 50 80 75, 100 10 to 50 100 75, 100 (mm)
Compact Cylinder: Water Resistant Double Acting, Single Rod Double clevis: CQ2D/CDQ2D 4xN Cap bolt CT CX +0.4 +0.2 CZ –0.1 –0.3 CU CW RR L1 A B LS A B LS L L1 LD LG LH LT 62.2 36 10 72.2 46 20 18 43.5 11 5 46 3.2 72.2 46 20 75 43.5 13.5 85 53.5 23.5 20 53.5 13 7 59 4.5 85 53.5 23.5 88 53 19 98 63 29 22 53.5 13 7 71 6 98 63 29 Foot bracket material: Carbon steel Bore size Stroke range Surface treatment: Nickel plated LX LY LZ X Y (mm) (mm) 10 to 50 95 91.5 113 16.
Compact Cylinder Series CDQ2 With Auto Switch 1 1 Auto Switch Proper Mounting Position (Detection at Stroke End) and its Mounting Height Applicable Cylinder Series: CDQ2, CDQ2W, CDQ2 - S/- T (Single acting), CDQ2, CDQ2W (Large bore size), CDQ2K, CDQ2KW (Non-rotating rod), CDQ2 (Long stroke), CDQ2 S (Anti-lateral load), CDQ2 R/ V (Water resistant) D-A9 D-M9 D-M9 W D-M9 AL D-A9 V D-M9 V D-M9 WV D-M9 AVL ø12 to ø25 A B ø32 to ø200 B A D-F7NTL D-F7BAL D-A73C D-A80C D-J79C D-A79W D-F7 WV D-F7 V D-F7BAV
Series CDQ2 Standard Compact Cylinder Auto Switch Proper Mounting Position Applicable Cylinder Series: CDQ2 (Double acting, Single rod) A B A B A B A B A B A B 6 9 9 9.5 12 16 14 16.5 19.5 24 7 6.5 7.5 8 9 11.5 14.5 17.5 22 27 4.5 7.5 7.5 8 9 13 11 13.5 16.5 21 5.5 5 6 6.5 6 8.5 11.5 14.5 19 24 5 8 8 8.5 9.5 13.5 11.5 14 17 21.5 6 5.5 6.5 7 6.5 9 12 15 19.5 24.5 10 13 13 13.5 14.5 18.5 16.5 19 22 26.5 11 10.5 11.5 12 11.5 14 17 20 24.5 29.5 2 5 5 5.5 6.5 10.5 8.5 11 14 18.5 3 2.
Compact Cylinder Series CDQ2 With Auto Switch 2 1 Auto Switch Proper Mounting Position (Detection at Stroke End) and its Mounting Height Auto Switch Proper Mounting Position Applicable Cylinder Series: CDQ2, CDQ2W (Large bore size) Auto switch model D-A9 D-A9 V Bore size 125 140 160 180 200 D-M9 D-M9 V D-M9 W D-M9 WV D-M9 AL D-M9 AVL D-A73 D-A80 A B A B A B 30 30 34 40.5 43.5 30 30 34 40.5 43.5 34 34 38 44.5 47.5 34 34 38 44.5 47.5 32.5 32.5 36.5 — — 32.5 32.5 36.
Series CDQ2 Standard Compact Cylinder Applicable Cylinder Series: CDQ2 S (Anti-lateral load) Bore size A B A B A B Applicable Cylinder Series: CDQ2 R/ V (Water resistant) D-M9 AL D-M9 AVL A B Auto switch model Bore size B A B A B A B 20.5 24 21.5 24 27 30 15.5 18.5 22 25 29.5 36 12.5 16 13.5 16 19 22 7.5 10.5 14 17 21.5 28 8 11.5 9.5 12 15 18 3.5 6.5 9.5 12.5 17 23.5 Non-rotating Rod 14 9 18 13 15 10 15.5 17.5 12 21.5 16 18.5 13 19 15 15.5 19 19.5 16 16.5 16.5 17.5 18.5 21.5 22.
Compact Cylinder Series CDQ2 With Auto Switch 3 2 Minimum Stroke for Auto Switch Mounting Applicable Cylinder Series: CDQ2, CDQ2W, CDQ2 - S/- T (Single acting), CDQ2K, CDQ2KW (Non-rotating rod), CDQ2 (Long stroke), CDQ2 S (Anti-lateral load), CDQ2 R/ V (Water resistant) D-A9 V D-A7 D-A80 D-A73C D-A80C D-A9 D-M9 WV D-M9 AVL∗ D-F7 WV D-F7BAVL D-M9 D-M9 W D-M9 AL∗ D-A7 H D-A80H D-F7 D-J79 D-A79W D-F7 W D-J79W D-F7BAL D-F79F D-F7NTL Number of auto switches D-M9 V D-F7 V D-J79C With 1 pc.
4 Auto Switch Mounting Brackets/Part No. Applicable auto switch D-M9 /M9 V D-M9 W/M9 WV D-M9 AL/M9 AVL D-A9 /A9 V Bore size (mm) Auto switch mounting bracket part no. D-F7 /F7 V/J79/J79C/F7 W/J79W/F7 WV D-F7BAL/F7BAVL/F79F/F7NTL D-A7 /A80/A7 H/A80H/A73C/A80C/A79W D-P3DW ø12 to ø200 ø12 to ø25 ø32 to ø160 ø32 to ø100 — BQ4-012 BQ5-032 BQ3-032S q Auto switch mounting screw (M2.5 x 8L) w Auto switch mounting nut Weight: 1.5 g q Auto switch fixing screw (M2.
Compact Cylinder Series CDQ2 With Auto Switch 4 Other than the applicable auto switches listed in “How to Order”, the following auto switches are mountable. Refer to pages 1263 to 1371 in Best Pneumatics No. 2 for detailed specifications.
Prior to Use Standard Auto Switch Connection and Example Basic Wiring Blue Indicator protection circuit, etc. Main circuit of switch Black Load Blue Blue Blue Brown Brown Load Black Brown Indicator protection circuit, etc.
Simple Specials/Made to Order Please contact SMC for detailed specifications, lead times, and pricing. Simple Specials The following special specifications can be ordered as a simplified made-to-order. There is a specification sheet available on paper and CD-ROM. Please contact your SMC sales representatives if necessary.
CQ2K (Non-rotating Rod) Double acting Single rod Single rod Double rod CQP2 (Axial Piping) Note 2) Double acting Single acting Single rod/ Single rod/ Single rod Spring return Spring extend CQ2 S CBQ2 (Anti-lateral Load) Double acting (With End Lock) Note 2) Double acting Single rod Single rod Page Large Bore Size CQ2 (Long Stroke) Double acting Series CQ2 Standard Simple Specials/Made to Order P.
Series CQ2 Simple Specials 1 These changes are dealt with Simple Specials System.
Simple Specials Series CQ2 Standard Symbol -XA1/2/6/7/11/17/18 Conditions of Manufacture For ø12 øJ: 4 mm or more, W1: 6 mm or less øM: ø10 mm or less øJ: 3 mm or more, W1: 6 mm or less ø16 øJ: 4 mm or more, W1: 6 mm or less øJ: 4 mm or more, W1: 6 mm or less ø20 øJ: 5 mm or more, W1: 11 mm or less øJ: 5 mm or more, W1: 11 mm or less ø25 øJ: 6 mm or more, W1: 13 mm or less øJ: 6 mm or more, W1: 13 mm or less For ø12 H: M4 or less H: M4 or less ø16 H: M6 or less H: M6 or less ø20 H:
Series CQ2 Simple Specials 2 These changes are dealt with Simple Specials System.
Series CQ2 Symbol -XA1 to XA23/-XA26 to XA30 Symbol: A15 øDA 30° X Symbol: A18 30° L Symbol: A20 30° H1 30° 30° øRD 30° E W 30° E X X L T F L H1 30° H1 ∗ W T X C1 X L With Auto Switch W Water Resistant Symbol: A30 L Auto Switch øDA 30° ∗ H1 L ∗ 30° LB K LA Symbol: A29 Symbol: A28 øDA X L L L ∗ 30° With End Lock X Symbol: A27 øDA ∗ H1 B X C T T X H1 30° ∗ øDB øDB H1 øDA øDA 30° Symbol: A26 Symbol: A23 Anti-lateral Load Symbol: A22 FK L
Series CQ2 Made to Order 1 Please contact SMC for detailed dimensions, specifications, and lead times. Symbol -XB6 Heat Resistant Cylinder (–10 to 150°C) The seal material and grease for air cylinders have been changed for high temperature tolerance, now with a range of –10 to 150°C. Applicable Series Series Standard CQ2 Axial piping Model Action CQ2 Double acting, Single rod CQ2W Double acting, Double rod CQP2 Double acting, Single rod How to Order CQ2 Standard model no.
Made to Order Series CQ2 -XB9 Standard Symbol Low-speed Cylinder (10 to 50 mm/s) Even if driving at lower speeds 10 to 50 mm/s, there would be no stick-slip phenomenon and it can run smoothly. Applicable Series Double acting, Double rod CQP2 Double acting, Single rod External dimensions Same as standard Specifications other than above Same as standard Be aware that smoking cigarettes, etc.
Series CQ2 Made to Order 2 Please contact SMC for detailed dimensions, specifications, and lead times. Symbol -XB10 Intermediate Stroke (Exclusive body type) Air cylinder which can reduce the mounting space by using an exclusive body which does not use a spacer to achieve that the full length dimension could be shortened when an intermediate stroke other than the standard stroke is required.
Series CQ2 Symbol -XB10 Standard Made to Order Double acting, Double rod/Large bore size Long Stroke Double acting, Single rod/Large bore size Large Bore Size Dimensions: Series CQ2 (mm) 125 140 160 180 200 A (mm) A B 24 stroke or less 26 to 99 stroke 65.5 80.5 69 84 72.5 82 83.5 85 24 stroke or less 26 to 99 stroke 61 66 64 69 65.5 75 75.5 77 A B 49 stroke or less 121 132.5 51 to 99 stroke 136 147.5 49 stroke or less 111 120.
Made to Order Series CQ2 Symbol -XB10 Symbol -XB10A Intermediate Stroke (Spacer-installed type) Intermediate stroke: Available in 1 mm intervals A spacer is installed on tubes with a stroke longer than the specified stroke ( in the below table).
Series CQ2 Made to Order 3 Please contact SMC for detailed dimensions, specifications, and lead times. Standard Symbol -XB11 Long Stroke (Air-hydro type only) Strokes exceeding the standard stroke length Series Air-hydro type (ø32 to ø100) CQ2 Model Action Note CQ2AH Double acting, Single rod The external dimensions are the same as those of the CQ2 series long stroke type air cylinder.
Made to Order Series CQ2 Symbol -XB14 Cylinder with Heat Resistant Auto Switch L Heat resistant compact cylinder CDQ2 series (ø16 to ø63), which can mount heat resistant solid state switch. (D-F7NJZ , Max. 150°C) Applicable Series Series CQ2 Standard Model Action Note CQ2 Double acting, Single rod Applicable to ø16 to ø63 Except with rubber bumper Body shape: Same as the existing product How to Order F7NJL Standard model no.
Made to Order Common Specifications: -XC2(A): Rod End Length Extended 10 mm -XC2(A) Standard Symbol Rod End Length Extended 10 mm Rod end length (L dimension) specifications of the cylinder for mounting the flange on the foot or rod side are “standard product + 10 mm” (-XC2).
Series CQ2 Made to Order 4 Please contact SMC for detailed dimensions, specifications, and lead times. Symbol -XC4 With Heavy-Duty Scraper Suitable for using cylinders under the environment, where there are much dusts in a surrounding area by using a heavy-duty scraper on the wiper ring, or using cylinders under earth and sand exposed to the die-casted equipment, construction machinery, or industrial vehicles.
Made to Order Series CQ2 -XC6 Standard Symbol Piston Rod/Retaining Ring/Rod End Nut Material: Stainless Steel Suitable for the cases it is likely to generate rust by water immersion or corrosion.
Series CQ2 Made to Order 5 Please contact SMC for detailed dimensions, specifications, and lead times. Symbol -XC8 Adjustable Stroke Cylinder/Adjustable Extension Type The extending stroke by the cylinder can be adjusted by the stroke adjustment mechanism equipped on the head end.
Made to Order Series CQ2 -XC9 Standard Symbol Adjustable Stroke Cylinder/Adjustable Retraction Type The retracting stroke of the cylinder can be adjusted by the adjusting bolt.
Series CQ2 Made to Order 6 Please contact SMC for detailed dimensions, specifications, and lead times. Symbol -XC10 Dual Stroke Cylinder/Double Rod Two cylinders are constructed as one cylinder in a back-to-back configuration allowing the cylinder stroke to be controlled in three steps.
Made to Order Series CQ2 Standard Symbol -XC11 Dual Stroke Cylinder/Single Rod Two cylinders can be integrated by connecting them in line, and the cylinder stroke can be controlled in two stages in both directions.
Series CQ2 Made to Order 7 Please contact SMC for detailed dimensions, specifications, and lead times. Symbol -XC26 With Split Pins for Double Clevis Pin/Double Knuckle Joint Pin and Flat Washers A pin for double clevis (one of the mounting types) or double knuckle joint (one of the accessories) has been changed for a split pin, and split pins and flat washers have been added.
Series CQ2 Symbol -XC27 Double Clevis Pin/Double Knuckle Joint Pin Material: Stainless Steel 304 For preventing the oscillating portion of the double clevis or the double knuckle joint from rusting, the material of the pin and the retaining ring has been changed to stainless steel.
Series CQ2 Made to Order 8 Please contact SMC for detailed dimensions, specifications, and lead times. Symbol -XC35 With Coil Scraper For getting rid of frost, ice, weld spatter, cutting chips adhered to the piston rod, and for protecting the seals, etc.
Made to Order Common Specifications: -XC85: Grease for Food Processing Equipment -XC85 Standard Symbol Grease for Food Processing Equipment Large Bore Size Food grade grease (certified by NSF-H1) is used as lubricant.
Made to Order Common Specifications: -XC92: Dust Resistant Actuator Symbol -XC92 Dust Resistant Actuator Applicable for environments with flying micro-powder (20 to 30 μm or less) such as ceramic powder, toner powder, paper powder, and metallic powder (except weld spatter). 4 times stronger than the standard model Applicable series Series CQ2 Description/Type Standard type Remark (s) Model Action CQ2 Double acting, Single rod C (D) Q2 Mounting bracket Bore size Applicable to ø32 to ø100.
Series CQ2 Made to Order Individual Specifications 1 Please contact SMC for detailed dimensions, specifications, and lead times. Standard Symbol -X144 Special Port Location For changing port location (ø12 to ø25 with auto switch only) C Special port location Large Bore Size ø20, ø25 ø12, ø16 X144 B D 5 5 In the case of CDQ2쏔20/25, specify the port location with B, C and D.
Series CQ2 Made to Order Individual Specifications 2 Please contact SMC for detailed dimensions, specifications, and lead times. Symbol -X202 Full Length Dimension is the Same as the CQ1 Series. C쏔Q2 Mounting Bore size (Z) Stroke Action Option X202 Mounting face of cylinder In a single rod cylinder of the CQ2 series, the A dimension (from the head face to the rod end) and the rod end female thread size are the same as those of the CQ1 series (former model).
Series CQ2 Symbol -X202 Dimensions (With auto switch) ø12 to ø25 ø32 to ø100 Auto switch H thread effective depth C ø12 Bore size Stroke (mm) 15, 25 Symbol A B L H C 36.5 33 3.5 M3 x 0.5 6 B + Stroke A + Stroke L ø20 5, 10, 20 30, 40, 50 ø32 15, 25 35, 45 38.5 43.5 31.5 36.5 7 7 M5 x 0.8 7 B + Stroke A + Stroke ø40 ø50 10, 20, 30 10, 20, 30 10, 20, 30 5, 15, 25 5, 15, 25 15, 25 40, 50, 75 40, 50, 75 40, 50, 75 35, 45 35, 45 35, 45 100 100 100 36.5 41.5 43 48 44 49 33 38 39.5 44.5 40.
Series CQ2 Made to Order Individual Specifications 3 Please contact SMC for detailed dimensions, specifications, and lead times. Symbol -X203 L Dimension from Rod Cover is the Same as the CQ1 Series. C쏔Q2 Mounting Bore size 10 Action Option Z X203 In a single rod cylinder of the CQ2 series, the L dimension (from the rod face to the rod end) and the rod end female thread size are the same as the CQ1 series (former model).
Series Made to Order Individual Specifications CQ2 Standard Symbol -X235 Special Rod End for Double Rod Cylinder Male thread is used at one piston rod end of double rod cylinder and female thread is used at the other end.
Series CQ2 Made to Order Individual Specifications 4 Please contact SMC for detailed dimensions, specifications, and lead times. Symbol -X293 Full Length Dimension is the Same as the CQ1W Series. C쏔Q2W X293 Standard model no.
Made to Order Individual Specifications Series CQ2 Standard Symbol -X525 Long Stroke of Adjustable Extension Stroke Cylinder (-XC8) Stroke X525 D(M)(Z) Large Bore Size C쏔Q2 Mounting Bore size Long stroke of -XC8 B C + Stroke L C + Stroke B A + Stroke Axial Piping A + Stroke C + Stroke A + Stroke ø12, ø16 Bore size Symbol S tro ke 12 16 B A C L Applicable stroke 87.4 24 3.5 92 24 3.5 35, 40 45, 50 35st 40st 45st 50st 35st 40st 45st 50st 99.9 104.9 109.9 114.
Series CQ2 Made to Order Individual Specifications 5 Please contact SMC for detailed dimensions, specifications, and lead times. Symbol -X526 Long Stroke of Adjustable Retraction Stroke Cylinder (-XC9) C쏔Q2 Mounting Bore size X526 D(M)(Z) Stroke The specifications are the same as those of -XC9 of the CQ2 series. Refer to “Made to Order.” Note) For models with a bracket, please contact SMC.
Made to Order Individual Specifications Series CQ2 Standard Symbol -X636 Long Stroke of Dual Stroke Single Rod Cylinder Bore size Stroke S1 Stroke S2–S1 (C)(M)(Z) X636 Large Bore Size C쏔Q2B Long stroke of -XC11 Applicable Stroke (mm) Bore size ø12, ø16 Stroke S2: Up to 50 mm ø20 to ø100 Stroke S2: Up to 100 mm Long Stroke Stroke Non-rotating Rod The specifications are the same as those of -XC11 of the CQ2 series. Refer to “Made to Order.
Series CQ2 Made to Order Individual Specifications 6 Please contact SMC for detailed dimensions, specifications, and lead times. Symbol -X1876 Cylinder Tube: With Concave Boss on Head Side C쏔Q2 C쏔Q2K Mounting C쏔Q2쏔S Bore size Stroke D(C)(M)(Z) S(M)(Z) T(M)(Z) X1876 With concave boss on head side The specifications are the same as those of the CQ2 series. Note) Except ø12, ø16 and ø125 to ø200 øTH10 G 235 Bore size (mm) TH10 G 20 19.3 +0.084 0 1.4 25 23.8 +0.084 0 1.4 32 30.9 +0.
Safety Instructions Caution: Warning: Danger : These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of “Caution,” “Warning” or “Danger.” They are all important notes for safety and must be followed in addition to International Standards (ISO/IEC)∗1), and other safety regulations.