Datasheet
Caution on Handling
Specifications
Action
Maximum operating pressure
Minimum operating pressure
Cushion
Standard stroke (mm)
Auto switch
Mounting
Double acting, Single rod
0.7 MPa
0.06 MPa
Rubber bumper (Standard equipment)
Same as standard type. (Refer to page 103.)
Mountable (Band mounting style)
Bottom mounting style
10, 16
Bore size (mm)
104
Series CJ2RK
Eliminates the effects by copper based ions and fluorine
based resins, etc. over the color cathode ray tube.
Making copper based materials into electroless nickel
plated treatment or changing them to the non-copper
materials in order to prevent copper ions from generating.
20-CJ2RK
Copper and fluorine-free
Copper and Fluorine-free Air Cylinder
(For CRT manufacturing process)
Bore size
Stroke
Head cover port location
쎲
Avoid using the air cylinder in such a way that rotational torque would be
applied to the piston rod because this will deform the non-rotating guide,
thus affecting the non-rotating accuracy.
<When mounting>
쎲
Operate the cylinder in such a way that the load to the piston rod is always
applied in the axial direction.
쎲
To screw a bracket onto the threaded portion at the tip of the piston rod,
make sure to retract the piston rod entirely, and place a wrench over the flat
portion of the rod that protrudes.
Tighten it by giving consideration to prevent the tightening torque from being
applied to the non-rotating guide.
Allowable rotational torque (N·m)
ø
10
0.02
ø
16
0.04
Caution
P0015-P0124-E.qxd 08.10.2 4:02 PM Page 104