Datasheet

For details, refer to the separate catalog “Pneumatic Clean Series”.
Action
Bore size (mm)
Maximum operating pressure
Minimum operating pressure
Cushion
Standard stroke (mm)
Auto switch
Mounting
Specifications
Double acting, Double rod
10, 16
0.7 MPa
0.1 MPa
Rubber bumper
Same as standard type. (Refer to page 53.)
Mountable (Band mounting style)
Basic style, Foot style, Flange style
Eliminates the effects by copper based ions and fluorine
based resins, etc. over the color cathode ray tube.
Making copper based materials into electroless nickel
plated treatment or changing them to the non-copper
materials in order to prevent copper ions from generating.
Action
Bore size (mm)
Maximum operating pressure
Minimum
operating pressure
Cushion
Standard stroke (mm)
Auto switch
Mounting
ø6
ø10, ø16
Double acting, Double rod
6, 10, 16
0.7 MPa
0.15 MPa
0.1 MPa
Rubber bumper
15, 30, 45, 60
Mountable (Band mounting style)
Basic style, Foot style, Flange style
Specifications
Copper and Fluorine-free Air Cylinder
(For CRT manufacturing process)
55
Series CJ2W
Air Cylinder: Standard Type
Double Acting, Double Rod
Clean Series
10
Clean Series
-CJ2W
Air cylinder which is applicable for the system which
discharges leakage from the rod section directly into the
outside of clean room by relief port and making an
actuator’s rod section having a double seal construction.
Bore sizeMounting style Stroke
Construction (Not able to disassemble)
Copper and fluorine-free
20-CJ2W
Bore sizeMounting style Stroke
CJ1
CJP
CJ2
CM2
CG1
MB
MB1
CA2
CS1
CS2
Individual
-X
D-
-X
Technical
data
P0015-P0124-E.qxd 08.10.2 4:00 PM Page 55