10 166
Bore size (mm)
Action
Fluid
Proof pressure
Maximum operating pressure
Minimum operating pressure
Ambient and fluid temperature
Cushion
Lubrication
Stroke length tolerance
Piston speed
Allowable kinetic energy
50 to 750 mm/s
50 to 1000 mm/s
0.035 J
Specifications
Double acting, Double rod
Air
1 MPa
0.7 MPa
0.1 MPa
Without auto switch: –10°C to 70°C, With auto switch: –10°C to 60°C
Rubber bumper/Air cushion
Not required (Non-lube)
+1.0
0
No freezing
Bore size (mm)
6, 10, 16
Standard stroke
15, 30, 45, 60
Standard Stroke (mm)
Manufacture of intermediate strokes at 1 mm intervals is possible. (Spacers are not used.)
JIS Symbol
Double acting, Double rod
• Minimum stroke for auto switch mounting
• Proper auto switch mounting position (detection at stroke end) and mounting height
• Operating range
• Switch mounting bracket part no.
Refer to pages 117 to 123 for cylinders with auto switches.
Rubber bumper
Air cushion
Rubber bumper
Air cushion
Rubber bumper
Air cushion
(Effective
cushion length)
0.1 MPa
0.012 J 0.090 J
0.18 J
(9.4 mm)
0.07 J
(9.4 mm)
53
Made to Order Specifications
(For details, refer to pages 1373 to 1498.)
Series CJ2W
Air Cylinder: Standard Type
Double Acting, Double Rod
Change of rod end shape
Symbol
Specifications
–XA
–XB6
–XB7
–XC22
–XC51
Heat resistant cylinder (150°C)
Not available with switch & with air cushion
Cold resistant cylinder
Not available with switch & with air cushion
Fluororubber seals
Not available with air cushion
With hose nipple