Datasheet
58
How to Order
Standard stroke
RoHS
∗ For applicable auto switches,
refer to the table below.
Auto switch
Built-in magnet
M9BW BZ6016
Z6016
L
With auto switch
CDJ2ZW
BCJ2ZW
B
Basic
L
Foot
F
Flange
10
10 mm
16
16 mm
—
2 pcs.
S
1 pc.
n
“n” pcs.
—
Without auto switch
∗ For rail mounting, screws and nuts
for 2 auto switches come with the
rail.
∗ Refer to page 84 for auto switch
mounting brackets.
Applicable Auto Switches/Refer to the Auto Switch Guide for further information on auto switches.
Series CJ2ZW
ø10, ø16
Air Cylinder: Built-in Speed Controller Type
Double Acting, Double Rod
∗ Since there are other applicable auto switches than listed, refer to page 85 for details.
∗ For details about auto switches with pre-wired connector, refer to the Auto Switch Guide.
∗ Solid state auto switches marked with “” are produced upon receipt of order.
∗
The D-A9쏔쏔/M9쏔쏔쏔/A7쏔쏔/A80쏔/F7쏔쏔/J7쏔쏔 auto switches are shipped together, (but not assembled). (For band mounting, only auto switch mounting brackets are assembled before being shipped.)
∗∗ Water resistant type auto switches can be mounted on the above models, but in such case SMC cannot guarantee water resistance.
Please contact SMC regarding water resistant types with the above model numbers.
∗ Lead wire length symbols: 0.5 m·················· — (Example) M9NW
1 m·················· M
(Example) M9NWM
3 m··················
L
(Example) M9NWL
5 m··················
Z
(Example) M9NWZ
None
···············
N
(Example) H7CN
Mounting
Bore size
Number of auto switches
Made to Order
Refer to page 59 for details.
∗ Mounting bracket is shipped
together with the product,
but not assembled.
Auto switch
mounting type
Type
Special function
Electrical
entry
Indicator light
Wiring
(Output)
Load voltage Auto switch model Lead wire length (m)
Pre-wired
connector
Applicable
load
DC AC
Band mounting Rail mounting
0.5
(—)
1
(M)
3
(L)
5
(Z)
None
(N)
Perpendicular
In-line
Perpendicular
In-line
Solid state auto switch
——
Grommet
Yes
3-wire (NPN)
24 V
5 V,12 V
—
M9NV M9N M9NV M9N
—
IC circuit
Relay,
PLC
3-wire (PNP)
M9PV M9P M9PV M9P
—
2-wire 12 V
M9BV M9B M9BV M9B
—
—
Connector
—
H7C J79C
—
—
—
Diagnostic indication
(2-colour indication)
Grommet
3-wire (NPN)
5 V,12 V
M9NWV M9NW M9NWV M9NW
—
IC circuit
3-wire (PNP)
M9PWV M9PW M9PWV M9PW
—
2-wire 12 V
M9BWV M9BW M9BWV M9BW
—
—
Water resistant
(2-colour indication)
3-wire (NPN)
5 V,12 V
M9NAV
∗∗
M9NA
∗∗
M9NAV
∗∗
M9NA
∗∗
—
IC circuit
3-wire (PNP)
M9PAV
∗∗
M9PA
∗∗
M9PAV
∗∗
M9PA
∗∗
—
2-wire 12 V
M9BAV
∗∗
M9BA
∗∗
M9BAV
∗∗
M9BA
∗∗
—
—
With diagnostic output (2-colour indication)
4-wire (NPN)
5 V,12 V
—
H7NF
—
F79F
—
—
IC circuit
Reed auto switch
——
Grommet
Yes
3-wire
(NPN equivalent)
—
5 V —
A96V A96 A96V A96
—
—— —
IC circuit
—
2-wire
— 200 V — —
A72 A72H
—
—— —
—
Relay,
PLC
24 V
12 V
100 V
A93V A93 A93V A93
—
——
No
100 V or less
A90V A90 A90V A90
—
—— —
IC circuit
Yes
——
C73C A73C
—
—
——
Connector
No
24 V or less
—
C80C A80C
—
—
—
IC circuit
Diagnostic indication (2-colour indication)
Grommet
Yes
—— — —
A79W
—
—
—— — —
A
Rail mounting
B
Band mounting
CJ2CJ2WCJ2CJ2KCJ2KCJ2ZCJ2ZWCJ2RCJ2RCJ2RKCJ2RK
StandardBuilt-in Speed ControllerDirect Mount
Double Acting, Single Rod
Double Acting, Double Rod
Single Acting, Spring Return/Extend
Double Acting, Single Rod
Single Acting, Spring Return/Extend
Double Acting, Single Rod
Double Acting, Double Rod
Double Acting, Single Rod
Single Acting, Spring Return/Extend
Double Acting, Single Rod
Auto Switch
Made to Order
Single Acting, Spring Return/Extend
Non-rotating RodDirect Mount, Non-rotating Rod