Datasheet
Minimum Auto Switch Mounting Stroke
D-H7첸/H7첸W
D-H7BAL
D-H7NF
D-C7첸
D-C80
D-C73C
D-C80C
D-H7C
D-M9첸V
D-A9첸V
D-M9첸
D-A9첸
D-M9첸WV
D-M9첸AVL
D-M9첸W
D-M9첸AL
D-A7첸/A80
D-A7첸H/A80H
D-A73C/A80C
D-A9첸
D-M9첸
D-M9첸W
Auto switch model
Auto switch mounting
1 pc.
2 pcs.
Different surfaces
n pcs. (n: No. of auto switch)
No. of auto switch mounted
10 15
Note) Note)
Same surface
45
10 15 50
10 15 60
10 15 65
Same surface
45 + 15 (n-2)
50 + 20 (n-2)
60 + 22.5 (n-2)
50 + 27.5 (n-2)
5 — 5
Band mounting
Rail mounting
(mm)
Different surfaces
—
15 + 35
(n = 2, 4, 6···)
(n-2)
2
15 + 40
(n = 2, 4, 6···)
(n-2)
2
15 + 45
(n = 2, 4, 6···)
(n-2)
2
15 + 50
(n = 2, 4, 6···)
(n-2)
2
10 + 10 (n-2)
(n = 4, 6···)
5 — 10 —
10 + 15 (n-2)
(n = 4, 6···)
10 — 10 —
15 + 15 (n-2)
(n = 4, 6···)
10 — 15 —
15 + 15 (n-2)
(n = 4, 6···)
15 — 15 —
20 + 15 (n-2)
(n = 4, 6···)
15 — 20 —
20 + 15 (n-2)
(n = 4, 6···)
D-A7첸H
D-A80H
D-A79W
D-F7첸
D-J79
D-F7첸V
D-J79C
D-F7첸W/J79W
D-F7BAL/F79F
D-F7NTL
D-F7첸WV
D-F7BAVL
15 + 15 (n-2)
(n = 4, 6···)
15 + 10 (n-2)
(n = 4, 6···)
10 + 15 (n-2)
(n = 4, 6···)
15 + 15 (n-2)
(n = 4, 6···)
10 + 10 (n-2)
(n = 4, 6···)
15 + 20 (n-2)
(n = 4, 6···)
10 + 15 (n-2)
(n = 4, 6···)
5 — 10
5 — 10
10 — 15
5 — 5
5 — 5
10 — 15
10 — 15
—
—
—
—
—
—
—
D-A93
D-M9첸
D-M9첸W
Auto switch model
With 2 auto switches
Different surfaces
—
Less than 20 strokes
Same surface
Less than 50 strokes
Less than 55 strokes
The auto switch is mounted by slightly displacing it in a direction
(cylinder tube circumferential exterior) so that the auto switch and
lead wire do not interfere with each other.
The proper auto switch mounting position is 5.5 mm inward from
the switch holder edge.
Note) When 2 D-A93/M9첸/M9첸W auto switches are included.
B-5.5
A-5.5
5.5
5.5
B
A
15
Auto switch
D-M9첸
D-M9첸W
122
Series CJ2
P0015-P0124-E.qxd 08.10.2 4:03 PM Page 122