Datasheet
Action
Fluid
Proof pressure
Maximum operating pressure
Minimum operating pressure
Ambient and fluid temperature
Cushion
Lubrication
Stroke length tolerance
Piston speed
Allowable kinetic energy
50 to 750 mm/s
0.090 J
Specifications
Double acting, Single rod
Air
1 MPa
0.7 MPa
0.15 MPa
∗∗
Without auto switch: –10°C to 70°C, With auto switch: –10°C to 60°C
∗
Rubber bumper
Not required (Non-lube)
+1.0
0
∗ No freezing
∗∗ 0.06 MPa for parts other than the lock unit.
Lock position
Holding force (Max.)
Lock release pressure
Backlash
Manual release
Lock Specifications
Head end, Rod end
98 N
0.15 MPa or less
1 mm or less
Non-locking type
∗ Manufacture of intermediate strokes at 1 mm intervals is possible. (Spacers are not used.)
Bore size
16
Standard stroke
Standard Stroke (mm)
15, 30, 45, 60, 75, 100, 125, 150, 175, 200
Series CJ2 air cylinder is
equipped with end lock function.
16
Bore size (mm)
• Minimum stroke for auto switch mounting
• Proper auto switch mounting position (detection at stroke end) and mounting height
• Operating range
• Switch mounting bracket part no.
Refer to pages 117 to 123 for cylinders with auto switches.
111
Air Cylinder: With End Lock
Series CBJ2
CJ1
CJP
CJ2
CM2
CG1
MB
MB1
CA2
CS1
CS2
Individual
-X쏔
D-쏔
-X쏔
Technical
data
P0015-P0124-E.qxd 08.10.2 4:03 PM Page 111