Datasheet
B port
C port A port
SA + Stroke ASB + Stroke B
Z + Stroke (A + B)
Intermediate cover
ACB
B stroke A stroke
A
AC
AC
B stroke A stroke
CB
A
stroke
B
B
B – A stroke
ACB
B stroke A stroke
ACB
B stroke A stroke
A
CB
A
stroke
C
B A
B stroke
ACB
B stroke A stroke
AC
B
W
A stroke
W
Two cylinders can be integrated by connecting them in line, and the cylinder stroke can be controlled in two stages in both directions.
8
Dual Stroke Cylinder/Single Rod Type
-XC11
Symbol
Applicable Series
Series Description Model Action Note
CJ2-Z
Standard type CJ2
Double acting,
Single rod
Except with
air cushion
Dual stroke cylinder/Single rod
How to Order
Mounting style
Bore size Stroke A Stroke B – A
XC11CJ2 Z
Specifi cations: Same as standard type
∗ Please contact SMC for each manufacturable stroke length.
[mm]
Bore size
SA SB Z
10
31.5 53 112.5
16
33 53 114
∗ Dimensions except mentioned above
are the same as standard type.
Note 1) When mounting an auto switch at the extended piston rod A side,
the following auto switches interfere with the intermediate cover. In
this case, please mount on the stroke B side. Please be aware that
the auto switch detects and temporarily turns ON/OFF when
passing the intermediate position of the B stroke.
Solid state auto switch: D-H7쏔, D-H7C, D-H7쏔W, D-H7NF,
D-H7BA
Reed auto switch: D-C7쏔, D-C80, D-C73C, D-C80C, D-A80,
D-A9쏔, D-A9쏔V, D-A79W, D-A73
Note 2) The maximum manufacturable stroke of this cylinder is 150 mm for
both A and B.
Dimensions (Dimensions other than below are the same as standard type.)
Functional description of dual stroke cylinder
A stroke or B stroke operation can be made individually.
Double output is possible.
4) Cylinder retraction
When the air pressure
is supplied from the
port, the rod
re-
tracts completely.
3) 2nd stage
(B-A stroke operation)
Following the 1st stage,
when the air pressure
is supplied from the
port, the rod operates
the B-A stroke.
2) 1st stage
(A stroke operation)
When the air pressure
is supplied from the
port, the rod
oper-
ates the A stroke.
1) Initial state
(0 stroke position)
2) Double output
When the air pressure is
supplied to the
and
ports at the same time, the
double output can be obtained
in the A stroke range.
1) Initial state
(0 stroke position)
B stroke operation
2) Operation
When the air pressure
is supplied from the
port, the rod
oper-
ates the B stroke.
1) Initial state
(0 stroke position)
A stroke operation
2) Operation
When the air pressure
is supplied from the
port, the rod
oper-
ates the A stroke.
1) Initial state
(0 stroke position)
1. Do not supply air until the cylinder is fi xed.
2. If air is supplied without securing the cylinder, the cylinder could lurch,
posing the risk of bodily injury or damage to the peripheral equipment.
Precautions
Caution
93
Series CJ2