Datasheet
How to Order
B
20 10
Bore size
 20
 25
 32
 40
 50
 63
 80
100
 20 mm
 25 mm
 32 mm
 40 mm
 50 mm
 63 mm
 80 mm
100 mm
Mounting style
B
L
F
G
C
Through-hole/Both ends 
tapped common (Standard)
Foot style
Rod side flange style
Head side flange style
Single clevis style
Cylinder stroke (mm)
Refer to page 2 for standard 
and intermediate strokes.
Rod end thread
Rod end female thread
Rod end male thread
Nil
M
∗ Lead wire length symbols:  0.5 m ·········· Nil  (Example) D-A93-588
   3 m ··········  L  (Example) D-A93L-588
   5 m ··········  Z  (Example) D-A93Z-588
∗  solid state auto switch is available after receiving an order.
Applicable auto switch specifications
Auto switch only conforms to Category 3. (II 3GD EEx nA II T5x -10°C ≤ Ta ≤ +60°C IP67)
For detailed specifications on the D-M9P(V), A93(V) and A90(V), please refer to page 16, 19.
(Note: Reed auto switches for 100 VAC and 100 VDC are not within the specification.
ModelType
Wiring
(output)
Load voltage
DC AC
Lead wire length (m) 
∗
0.5
(Nil)
3
(L)
5
(Z)
Applicable
load
Electrical entry
D-M9PV-588
D-M9P-588
D-M9PWV-588
D-M9PW-588
D-A93V-588
D-A90V-588
D-A93-588
D-A90-588
Grommet (Perpendicular)
Grommet (Perpendicular)
Grommet (in-line)
Grommet (Perpendicular)
Grommet (in-line)
Grommet (in-line)
Yes
No
Yes
No
Yes
Yes
(2-color)
2-wire
3-wire
(PNP)
24 V
24 V
24 V or less
24 V
24 V or less
5V, 12 V
12 V
48 V
12 V
48 V
—
—
48 V or less
—
48 V or less
—
—
Relay,
PLC
When using an Auto switch, select the appropriate switch from the following table and order it separately.
C
D
5555
Magnet
None
Built-in magnet
Nil
D
ATEX directive category 2
Compliant with
ATEX directive category 2
55
Specifications
Type
Action
Fluid
Proof pressure
Maximum operating pressure
Minimum operating pressure
Ambient and fluid temperature
Cushion
Pneumatic (Non-lube)
Double acting, Single rod
Air
1.5 MPa
1.0 MPa
–10 to 60°C (No freezing)
Rubber bumper on both end
+1.0
 0 mm
Through-hole/Both ends tapped common
50 to 500 mm/s
50 to 300 mm/s
Mounting
Piston speed
ø20 to ø63
ø80, ø100
Stroke length tolerance
Note) Stroke length tolerance dose not include the amount of bumper 
change.
0.05 MPa (ø20 to ø63)
0.03 MPa (ø80, ø100)
Indicator
light
Reed switch
Solid state
switch
IC circuit
—
IC circuit
—
IC circuit
Note)  When mounting an auto switch on a 55-series (Category 2) model, the ATEX class of the cylinder with auto switch changes to Category 3, which is 
the same class as the auto switch.
22
ISO Standards [ISO/21287]
Compact Cylinder 
(ATEX directive category 2)
ø20,ø25,ø32,ø40,ø50,ø63,ø80,ø100
Series 55-C55