Datasheet

How to Order
ISO Cylinder: Standard
Double Acting, Single/Double Rod
Series CP96
ø32, ø40, ø50, ø63, ø80, ø100, ø125
Mounting
B
L
F
G
C
D
Basic/Without bracket
Axial foot
Rod end flange
Head end flange
Single rear clevis
Double rear clevis
Rod boot
J
JJ
K
KK
Without boot
Nylon tarpaulin (one end)
Nylon tarpaulin (both ends)
Heat resistant tarpaulin (one end)
Heat resistant tarpaulin (both ends)
CP96SD
Built-in magnet
B 32 100
Number of
auto switches
Auto switch
Without auto switch
M9BW
J
S
3
n
2 pcs.
1 pc.
3 pcs.
“n” pcs.
W
Made to
Order
Refer to the
page 6 for
details.
S
For applicable auto switch
model, refer to the below
table.
With auto switch
Stroke (mm)
Applicable Auto Switches
Lead wire length symbols: 0.5 m ········· — (Example) M9NW
1 m ········· M (Example) M9NWM
3 m ········· L (Example) M9NWL
5 m ········· Z (Example) M9NWZ
Solid state switches marked with “p” are produced upon receipt of order.
Since there are other applicable auto switches than listed, refer to the auto switch guide.
For details about auto switches with pre-wired connector, refer to the auto switch guide.
D-A9l, M9l, M9lW, M9lAL are shipped together, (but not assembled).
(Switch mounting bracket is only assembled at the time of shipment.)
∗∗ Water resistant type auto switches can be mounted on the above models, but in such case SMC cannot guarantee water resistance.
Consult with SMC regarding water resistant types with the above model numbers.
Note) D-Y59A, Y69A, Y7P, Y7lW, Z7l, Z80 type cannot be mounted on the CP96 series.
Moreover, D-M9ll and A9l type cannot be mounted on square groove of the CP96 series.
Type
Special function
Grommet
Grommet
Grommet
Yes
Yes
None
3-wire (NPN)
3-wire (PNP)
2-wire
3-wire (NPN)
3-wire (PNP)
2-wire
3-wire (NPN)
3-wire (PNP)
2-wire
2-wire
3-wire
(Equiv. to NPN)
24 V
24 V
5 V, 12 V
12 V
12 V
12 V
5 V, 12 V
5 V, 12 V
5 V
12 V
100 V
100 V or less
M9N
M9P
M9B
M9NW
M9PW
M9BW
M9NA
∗∗
M9PA
∗∗
M9BA
∗∗
A96
A93
A90
IC
IC
IC
IC
IC
Relay,
PLC
Relay,
PLC
Electrical
entry
Indicator
light
Wiring
(Output)
Pre-wired
connector
Applicable
load
DC
Load voltage
Auto switch
model
Lead wire length (m)
AC
P
P
P
P
P
P
p
p
p
0.5
P
P
P
P
P
P
P
P
P
3
(L)
P
P
P
P
P
P
p
p
p
1
(M)
p
p
p
p
p
p
p
p
p
p
p
p
p
p
p
p
p
p
P P
P
P
P
P
5
(Z)
Reed
switch
Solid state switch
Bore size
32
40
50
63
80
100
125
32 mm
40 mm
50 mm
63 mm
80 mm
100 mm
125 mm
W
Single rod
Double rod
Rod
Diagnosis
indication
(2-colour)
Water resistant
(2-colour)
(Refer to Standard Stroke” on page 6.)
4