5. Piping
AXTS040*-2(B)-X2 Symbol for internal pilot fluid passage
Fig.3 Symbol for internal pilot fluid passage.
Caution
Continuous blow air can be changed to pulse air without electrical wiring by connecting the
pulse blow valve between air blow 2 port valve and nozzle of existing equipment.
When an air gun and a pressure regulator are connected to OUT port, the back pressure of
the OUT port will be high. Therefore, the product cannot be used.
When a vacuum ejector and a suction filter are connected to the OUT port, the back pressure
of the OUT port will be higher due to the clogging of the filter and silencer of the vacuum
ejector during operation. Therefore, the product cannot be used. In that case, please use the
external pilot type to avoid the influence of the back pressure.
Keep using the plug and port with silencer.
Direct manual override is operated by flat blade screwdriver. Insert the flat blade driver to the
groove until it contacts the bottom of the groove and turn the driver 90 degrees. Rotating
direction does not matter. Do the same for release (push and rotate for 90 degrees).
Tighten the piping using the correct torque shown below.
Table.1
Thread
Appropriate tightening
torque (Nm)
1/2
20 to 25
AXTS040*-2(B)-X2
Air blow
2-port valve
OUT Port
4(A)
IN