Datasheet

376
Specifications
Proof pressure
Maximum operating pressure
Set pressure range
1.5 MPa
1.0 MPa
0.05 to 0.4 MPa
Applicable Model
Port size
Model
AW10 AW30(K) AW40(K)
AW40(K)-06
M5
AW20(K)
1/8, 1/4 1/4, 3/8 1/4, 3/8, 1/2 3/4
AW60(K)
3/4, 1
Applicable Model/Drain Capacity
Port size
Drain capacity (cm
3
)
Model AW10
M5
9
AW30(K)
1/4, 3/8
43
AW40(K)
1/4, 3/8, 1/2
AW40(K)-06
3/4
AW20(K)
1/8, 1/4
19
88
AW60(K)
3/4, 1
30
AW
X40603
Note 1) The AW10 type comes with a backflow function as a standard feature. (K is not
available.) When using the AW10 type as w/ backflow function, backflow may
not occur with the set pressure 0.15 MPa or less. Please set the inlet pressure
to at least 0.05 MPa higher than the set pressure.
Note 2) Drain guide is NPT 1/8 (applicable to the AW20(K)) and NPT 1/4 (applicable to
the AW30(K) to AW60(K)). The auto drain port comes with ø3/8" One-touch
fitting (applicable to the AW30(K) to AW60(K)).
Note 3) Drain guide is G 1/8 (applicable to the AW20(K)) and G 1/4 (applicable to the
AW30(K) to AW60(K)).
Note 4) Option B, G, H, M are not assembled and supplied loose at the time of
shipment.
Note 5) Assembly of a bracket and set nuts. (AW10, AW20(K) to AW40(K)).
Including 2 mounting screws for the AW60(K)
Note 6) When choosing with H (panel mount), the installation space for lead wires will
not be secured. In this case, select “wiring down entry” for the electrial entry.
e 0.4 MPa Setting r Long Bowl
The maximum set pressure is 0.4 MPa. When a pressure gauge
is included, the display will show a range from 0 to 0.4 MPa.
Drain capacity is greater than that of standard models.
10 20 30 40 60
Body size
Description
Without backflow function
With backflow function
Symbol
Nil
K
Note 1)
With backflow
function
M5
1/8
1/4
3/8
1/2
3/4
1
M5
01
02
03
04
06
10
Port size
Without mounting option
With bracket
With set nut (for panel fitting)
Nil
B
Note 5)
H
Nil
E
G
M
E1
Note 6)
E2
Note 6)
E3
Note 6)
E4
Note 6)
Mounting
a
Without pressure gauge
Square embedded type pressure gauge (with limit indicator)
Round type pressure gauge (without limit indicator)
Round type pressure gauge (with limit indicator)
Round type pressure gauge (with color zone)
Output: NPN output / Electrical entry: Wiring bottom entry
Output: NPN output / Electrical entry: Wiring top entry
Output: PNP output / Electrical entry: Wiring bottom entry
Output: PNP output / Electrical entry: Wiring top entry
Pressure
gauge
Digital
pressure
switch
c
+
+
+
10 20 30 40 60
Without auto drain
Float type auto drain (N.C.)
Float type auto drain (N.O.)
Nil
C
D
Float type
auto drain
b
+
+
Body size
Metric thread (M5)
Rc
NPT
G
Nil
N
Note 2)
F
Note 3)
Thread type
Filter Regulator
AW10 to AW60
Filter Regulator with Backflow Function
AW20K to AW60K
Made to Order Specifications:
Please contact SMC for detailed dimensions, specifications, and lead times.
How to Order
X406
X64
0.4 MPa setting
Long bowl
0.4 MPa Setting Long Bowl
Note) Please consult SMC for dimensions.
Option/Semi-standard: Select one each for a to h.
Option/Semi-standard symbol: When more than one specification is required, indicate in
alphanumeric order.
Example) AW30K-03BE-2N-X406
Option
Note 4)
P0365-P0446-E.qxd 08.11.6 2:09 PM Page 376