Datasheet

18
Air Combination
Series AC10B-A to AC40B-A
AC
AF
AR
ALAW
ALAF
ARAF
AFM
ARAW
AFM
AF Attachment
AFM / AFD
ARALAW
Symbol Description
q
Body size
10 20 25 30 40
y
Semi-standard
h
Exhaust
mechanism
Relieving type

N
Non-relieving type

+
i Flow direction
Flow direction: Left to right

R
Flow direction: Right to left

+
j Pressure unit
Name plate and pressure gauge in imperial units: MPa

Z
Note 16)
Name plate, caution plate for bowl, and pressure gauge in imperial units: psi, °F
Note 17)
Note 17)
Note 17)
Note 17)
Note 17)
Model
AC10B-A AC20B-A AC25B-A AC30B-A AC40B-A AC40B-06-A
Component
Air Filter [AF]
AF10-A AF20-A AF30-A AF30-A AF40-A AF40-06-A
Regulator [AR]
AR10-A AR20-A AR25-A AR30-A AR40-A AR40-06-A
Port size M5 x 0.8 1/8, 1/4 1/4, 3/8 1/4, 3/8 1/4, 3/8, 1/2 3/4
Pressure gauge port size [AR] 1/16 1/8
Fluid Air
Ambient and fluid temperature –5 to 60 °C (with no freezing)
Proof pressure 1.5 MPa
Maximum operating pressure 1.0 MPa
Set pressure range [AR] 0.05 to 0.7 MPa
Nominal fi ltration rating [AF] 5 μm
Bowl material [AF] Polycarbonate
Bowl guard [AF]
Semi-standard (Steel)
Standard (Polycarbonate)
Construction [AR] Relieving type
Weight [kg] 0.16 0.28 0.43 0.58 1.05 1.12
Note 1) Drain guide is NPT1/8 (applicable to the
AC20B-A) and NPT1/4 (applicable to the
AC25B-A to AC40B-A). The auto drain port
comes with ø3/8" One-touch fi tting (applicable
to the AC25B-A to AC40B-A).
Note 2) Drain guide is G1/8 (applicable to the
AC20B-A) and G1/4 (applicable to the
AC25B-A to AC40B-A).
Note 3) Option G, M are not assembled and supplied
loose at the time of shipment.
Note 4) When pressure is not applied, condensate
which does not start the auto drain mechanism
will be left in the bowl. Releasing the residual
condensate before ending operations for the
day is recommended.
Note 5) If the compressor is small (0.75 kW, discharge
ow is less than 100 L/min[ANR]), air leakage
from the drain cock may occur during start of
operations. N.C. type is recommended.
Note 6) When the pressure gauge is attached, a 1.0
MPa pressure gauge will be fi tted for standard
(0.7 MPa) type. 0.4 MPa pressure gauge for
0.2 MPa type (1.0 MPa pressure gauge only
for the AC10B-A).
Note 7)
The bracket position varies depending on the
T-spacer or pressure switch mounting.
Note 8) Make sure that the outlet pressure is released
to atmospheric pressure using a pressure
gauge. For V1 specifi cation, use the regulator
with a set pressure of 0.15 MPa or more to
ensure the pressure release.
Note 9) Pressure can be set higher than the
specifi cation pressure in some cases, but use
pressure within the specifi cation range.
Note 10) Refer to Chemical data on page 38 for
chemical resistance of the bowl.
Note 11) A bowl guard is provided as standard
equipment (polycarbonate).
Note 12) A bowl guard is provided as standard
equipment (nylon).
Note 13) Float type auto drain: The combination of C
and D is not possible.
Note 14) Without a valve function
Note 15) The combination of metal bowl: 2 and 8 is not
available.
Note 16) For pipe thread type: M5, NPT. MPa and psi
are shown together on the pressure unit.
Cannot be used with M: Round pressure
gauge (with colour zone). Available by request
for special.
Note 17)
: For pipe thread type: M5, NPT only
Standard Specifi cations
AC40B-A
AC20B-AAC10B-A