Datasheet
14
Air Combination
Series AC10A-A to AC40A-A
AC
AF
AR
ALAW
ALAF
ARAF
AFM
ARAW
AFM
AF Attachment
AFM / AFD
ARALAW
Symbol
Description
q
Body size
10 20 30 40
y
Semi-standard
i
Lubricator lubricant
exhaust port
—
Without drain cock
3
Note 16)
Lubricator with drain cock
+
j
Exhaust
mechanism
—
Relieving type
N
Non-relieving type
+
k Flow direction
—
Flow direction: Left to right
R
Flow direction: Right to left
+
l Pressure unit
—
Name plate and pressure gauge in imperial units: MPa
Z
Note 17)
Name plate, caution plate for bowl, and pressure gauge in imperial units: psi, °F
Note 18)
Note 18)
Note 18)
Note 18)
Model
AC10A-A AC20A-A AC30A-A AC40A-A AC40A-06-A
Component
Filter Regulator [AW]
AW10-A AW20-A AW30-A AW40-A AW40-06-A
Lubricator [AL]
AL10-A AL20-A AL30-A AL40-A AL40-06-A
Port size M5 x 0.8 1/8, 1/4 1/4, 3/8 1/4, 3/8, 1/2 3/4
Pressure gauge port size [AW] 1/16 1/8
Fluid Air
Ambient and fluid temperature –5 to 60 °C (with no freezing)
Proof pressure 1.5 MPa
Maximum operating pressure 1.0 MPa
Set pressure range [AW] 0.05 to 0.7 MPa
Nominal fi ltration rating [AW] 5 μm
Recommended lubricant [AL] Class 1 turbine oil (ISO VG32)
Bowl material [AW/AL] Polycarbonate
Bowl guard [AW/AL]
—
Semi-standard (Steel)
Standard (Polycarbonate)
Construction [AW] Relieving type
Weight [kg] 0.20 0.34 0.67 1.24 1.35
Standard Specifi cations
AC40A-A
AC20A-AAC10A-A
Note 1) Drain guide is NPT1/8 (applicable to the AC20A-A) and
NPT1/4 (applicable to the AC30A-A to AC40A-A). The
auto drain port comes with ø3/8" One-touch fitting
(applicable to the AC30A-A to AC40A-A).
Note 2) Drain guide is G1/8 (applicable to the AC20A-A) and
G1/4 (applicable to the AC30A-A to AC40A-A).
Note 3) Option G, M are not assembled and supplied loose at
the time of shipment.
Note 4) When pressure is not applied, condensate which does
not start the auto drain mechanism will be left in the
bowl. Releasing the residual condensate before ending
operations for the day is recommended.
Note 5) If the compressor is small (0.75 kW, discharge fl ow is
less than 100 L/min[ANR]), air leakage from the drain
cock may occur during start of operations. N.C. type is
recommended.
Note 6) When the pressure gauge is attached, a 1.0 MPa
pressure gauge will be fi tted for standard (0.7 MPa) type.
0.4 MPa pressure gauge for 0.2 MPa type (1.0 MPa
pressure gauge only for the AC10A-A).
Note 7) Not available with piping port size: 06
Note 8) The bracket position varies depending on the pressure
switch mounting.
Note 9) Pressure can be set higher than the specification
pressure in some cases, but use pressure within the
specifi cation range.
Note 10) Refer to Chemical data on page 38 for chemical
resistance of the bowl.
Note 11) A bowl guard is provided as standard equipment
(polycarbonate).
Note 12) A bowl guard is provided as standard equipment
(nylon).
Note 13) Float type auto drain: The combination of C and D is
not possible.
Note 14) Without a valve function
Note 15) The combination of metal bowl: 2 and 8 is not available.
Note 16) When choosing with W: Filter regulator drain port, the
drain cock of a lubricator will be with barb fi tting.
Note 17) For pipe thread type: M5, NPT. MPa and psi are shown
together on the pressure unit. Cannot be used with M:
Round pressure gauge (with colour zone). Available by
request for special.
Note 18)
: For pipe thread type: M5, NPT only