Datasheet

4
98
5 µm
1.0 MPa (10 bar)
4000 l
n
/min
5 µm
0.7 MPa (7 bar)
290 l
n
/min
IP67
SV1100-5FU 66 g
SV1100R-5FU
66 g
SV1200-5FU 71 g
SV1200R-5FU
71 g
SV1300-5FU 73 g
SV1300R-5FU
73 g
SV1400-5FU 73 g
SV1400R-5FU
73 g
SV1500-5FU 73 g
SV1500R-5FU
73 g
SV1A00-5FU 71 g
SV1B00-5FU 71 g
SV1C00-5FU 71 g
SV1000-60-5A-1A
SV1000-60-5B-1A
SS5V1-W10S10D-02D-C6 2
SS5V1-W10S10D-04B-C6 4
SS5V1-W10S10D-06B-C6 6
SS5V1-W10S10D-08B-C6 8
SS5V1-W10S10D-10B-C6 10
SS5V1-W10S10D-12B-C6 12
SS5V1-W10S10D-14B-C6 14
SS5V1-W10S10D-16B-C6 16
SS5V1-W10S10D-18B-C6 18
SS5V1-W10S10D-20B-C6 20
VVQC1000-F25-1
VVQC1000-P26-1
VVQC1000-M26-1
Subject to change
SOLENOID VALVES, MECHANICAL AND MANUAL VALVES
= DELIVERY EX-STOCK FOR MORE INFO, ASK THE SMC EXPERTS: PHONE +31 (0) 20 531 88 88 / INFO@SMCPNEUMATICS.NL
VQ5000 solenoid valve, plug-in
Medium Compressed air, lubricated or not lubricated
Degree of ltration
Max. working pressure
Min. working pressure
(rubber seal/metal seal)
5/2 mono stable: 0.2 MPa (2 bar)/0.1 MPa (1 bar);
5/2 bi stable: 0.15 MPa (1.5 bar)/0.1 MPa (1 bar);
5/3 with center position: 0.2 MPa (2 bar)/0.15 MPa (1.5 bar)
Operating temperature –10 to 50 °C (dry air)
Voltage/power 24 VDC ±10% (other voltages on request)/1 W
Flow
Enclosure IP65 (except for D-sub)
Manual override Standard: non-lockable (lockable on request)
LED, surge voltage suppressor Standard
For more information, contact SMC.
More compact than ISO 3 Lower weight More accessories
SV1000 solenoid valve, tie rod type
Medium Air, lubricated or not lubricated (dry)
Degree of ltration
Max. working pressure
Min. working pressure
5/2 mono stable: 0.15 MPa (1.5 bar);
5/2 bi stable: 0.1 MPa (1 bar);
5/3 with center position: 0.2 MPa (2 bar);
double 3/2: 0.15 MPa (1.5 bar)
Operating temperature Up to 50 °C (dry air)
Voltage/power
Standard: 24 VDC (12 VDC
on request)/0.65 W
Flow
Enclosure
Manual override Standard: non-lockable
LED, surge voltage suppressor Standard, valve has no polarity
Easy to expand, connectors between valves Highest enclosure IP67
Valve plug-in
Part number
1
Type Weight
5/2 mono stable, rubber seal
5/2 mono stable, rubber seal,
external pilot
5/2 bi stable, rubber seal
5/2 bi stable, rubber seal,
external pilot
5/3 closed center, rubber seal
5/3 closed center, rubber seal,
external pilot
5/3 exhausted center, rubber seal
5/3 exhausted center, rubber seal,
external pilot
5/3 pressurized center, rubber seal
5/3 pressurized center, rubber seal,
external pilot
5/4 double 3/2, NC/NC, rubber seal
5/4 double 3/2, NO/NO, rubber seal
5/4 double 3/2, NC/NO, rubber seal
1. Add D for lockable manual override. Example: SV1100-5FUD.
Output modules – for electrical accessories, see EX500 eldbus
Part number Type
1
One normally open relay output,
110 VAC/3 A, 30 VDC/3 A
Two normally open relay outputs,
110 VAC/0.3 A, 30 VDC/1 A
1. Load capacity for resistive loads.
Sub plates
basic type
1
, add electrical connection below
Part number Number of stations
1. For other versions, contact SMC.
Electrical connections interface modules
Part number Type
D-sub, 25-pin
Flat cable, 26-pin
Circular connector,
26-pin (IP67)
Fieldbus EX250, EX260, EX500 and EX600, see chapter 5
Use interface for VQC series for sub plates above.
= DELIVERY EX-STOCK FOR MORE INFO, ASK THE SMC EXPERTS: PHONE +32 (0) 3 355 1464 / INFO@SMCPNEUMATICS.BE