Datasheet
4
90
■
5 µm
0.7 MPa (7 bar)
I
VV5QC21-02C8SD0 2
VV5QC21-04C8SD0 4
VV5QC21-06C8SD0 6
VV5QC21-08C8SD0 8
VV5QC21-10C8SD0 10
VV5QC21-12C8SD0 12
VVQC1000-F25-1
VVQC1000-P26-1
VVQC1000-M26-1
VVQC1000-T0-1
VVQC1000-L25-0-1
VVQC1000-L25-1-1
VVQC1000-L25-2-1
VVQ1000-51A-
VVQ2000-52A-C10
AN200-KM10
VVQ2000-10A-1
KQ2P-
VVQ1000-58A
VVQ2000-P-1-C8
VQC2101N-51 800 l
n
/min 95 g
VQC2100N-51 600 l
n
/min 105 g
VQC2201N-51 800 l
n
/min 105 g
VQC2200N-51 600 l
n
/min 105 g
VQC2301N-51 600 l
n
/min 105 g
VQC2401N-51 800 l
n
/min 105 g
VQC2501N-51 600 l
n
/min 105 g
VQC2A01N-51 460 l
n
/min 105 g
VQC2B01N-51 460 l
n
/min 105 g
VQC2C01N-51 460 l
n
/min 105 g
B C D
Subject to change
SOLENOID VALVES, MECHANICAL AND MANUAL VALVES
= DELIVERY EX-STOCK FOR MORE INFO, ASK THE SMC EXPERTS: PHONE +31 (0) 20 531 88 88 / INFO@SMCPNEUMATICS.NL
VQC2000 – solenoid valve, plug-in
Medium Air, lubricated or not lubricated (dry)
Degree of ltration
Max. working pressure
Min. working pressure
5/2 mono stable: 0.15 MPa (1.5 bar);
5/2 bi stable: 0.1 MPa (1 bar);
5/3 with center position: 0.2 MPa (2 bar);
double 3/2: 0.15 MPa (1.5 bar);
metal seal (not double 3/2): 0.1 MPa (1 bar)
Operating temperature Up to 50 °C (dry air)
Voltage/power
Standard: 24 VDC ±10% (12 VDC
on request)/0.4 W
Flow See table below
Enclosure
IP67, factory-assembled in Japan; otherwise
IP65; D-sub or at cable, IP50
Manual override Standard: non-lockable
LED, surge voltage suppressor Standard
■ Unmatched exibility and easy conguration because of new internal connector technology
Sub plates
– basic type, add electrical connection below.
Part number Stations
Additions – for sub plates above
Additions
Built-in silencer (…SD0-S)
Manifold 13–24 valve stations/added station
1
Separate pilot supply (…SD0-R)/manifold
1. Note! Manifold specification required; contact SMC.
Electrical connections – interface modules
Part number Type
D-sub, 25-pin
Flat cable, 26-pin
Circular connector,
26-pin (IP67)
Terminal box, 20 connections (IP67)
Molded cable, 0.6 m
Molded cable, 1.5 m
Molded cable, 3 m
Fieldbus – EX250, EX500 and EX600, see chapter 5
Replacement tting
Part number
= C4 for Ø4 mm; C6 for Ø6 mm; C8 for Ø8 mm.
Parallel tting – 2 valve stations
Part number
Silencer – for exhaust
Part number
Blanking plate – for unused valve stations
Part number
Blanking plug – in place of unused connections
Part number
= 04 for Ø4 mm; 06 for Ø6 mm; 08 for Ø8 mm.
Blanking plug – in place of tting
Part number
Individual P-supply
Part number
Valve – plug-in, 24 VDC
Part number
1
Type Flow Weight
5/2 mono stable, rubber seal
5/2 mono stable, metal seal
5/2 bi stable, rubber seal
5/2 bi stable, metal seal
5/3 closed center, rubber seal
5/3 exhausted center, rubber seal
5/3 pressurized center, rubber seal
Double 3/2 NC/NC, rubber seal
Double 3/2 NO/NO, rubber seal
Double 3/2 NC/NO, rubber seal
1. For lockable manual override, add B, C or D at end of part number. Example: VQC2101N-51B.
Blanking plateParallel tting
Manual override
versions
= DELIVERY EX-STOCK FOR MORE INFO, ASK THE SMC EXPERTS: PHONE +32 (0) 3 355 1464 / INFO@SMCPNEUMATICS.BE