Datasheet

7
336
LXSH2SA LXSH2SB LXSH5SA LXSH5SB
50, 75, 100, 125, 150 mm
9 kg 4.5 kg 6 kg 3 kg
4 kg 2 kg 2 kg 1 kg
100 mm/s 200 mm/s 100 mm/s 200 mm/s
60 N
±0.05 mm
LXSH2SA-50S-Q 50 mm 6 mm
LXSH2SA-75S-Q 75 mm 6 mm
LXSH2SA-100S-Q 100 mm 6 mm
LXSH2SA-125S-Q 125 mm 6 mm
LXSH2SA-150S-Q 150 mm 6 mm
LXSH2SB-50S-Q 50 mm 12 mm
LXSH2SB-75S-Q 75 mm 12 mm
LXSH2SB-100S-Q 100 mm 12 mm
LXSH2SB-125S-Q 125 mm 12 mm
LXSH2SB-150S-Q 150 mm 12 mm
LXSH5SA-50S-Q 50 mm 6 mm
LXSH5SA-75S-Q 75 mm 6 mm
LXSH5SA-100S-Q 100 mm 6 mm
LXSH5SA-125S-Q 125 mm 6 mm
LXSH5SA-150S-Q 150 mm 6 mm
LXSH5SB-50S-Q 50 mm 12 mm
LXSH5SB-75S-Q 75 mm 12 mm
LXSH5SB-100S-Q 100 mm 12 mm
LXSH5SB-125S-Q 125 mm 12 mm
LXSH5SB-150S-Q 150 mm 12 mm
LXSH2SA-75SB-Q 75 mm 6 mm
LXSH2SA-100SB-Q 100 mm 6 mm
LXSH2SA-125SB-Q 125 mm 6 mm
LXSH2SB-50SB-Q 50 mm 12 mm
LXSH2SB-75SB-Q 75 mm 12 mm
LXSH2SB-100SB-Q 100 mm 12 mm
LXSH2SB-125SB-Q 125 mm 12 mm
LXSH2SB-150SB-Q 150 mm 12 mm
LXSH5SA-50SB-Q 50 mm 6 mm
LXSH5SA-75SB-Q 75 mm 6 mm
LXSH5SA-100SB-Q 100 mm 6 mm
LXSH5SA-125SB-Q 125 mm 6 mm
LXSH5SA-150SB-Q 150 mm 6 mm
LXSH5SB-50SB-Q 50 mm 12 mm
LXSH5SB-75SB-Q 75 mm 12 mm
LXSH5SB-100SB-Q 100 mm 12 mm
LXSH5SB-125SB-Q 125 mm 12 mm
LXSH5SB-150SB-Q 150 mm 12 mm
LXSB5S
LC6D-220AD
LXSB5S
LC6D-507AD
Subject to change
ELECTRIC ACTUATORS
= DELIVERY EX-STOCK FOR MORE INFO, ASK THE SMC EXPERTS: PHONE +31 (0) 20 531 88 88 / INFO@SMCPNEUMATICS.NL
LXS compact electric slide unit
(stepper motor)
Model
Stroke
Motor 2-phase stepper motor 5-phase stepper motor
Screw
Ø8,
pitch 6 mm
Ø8,
pitch 12 mm
Ø8,
pitch 6 mm
Ø8,
pitch 12 mm
Max. load (horizontal)
Max. payload (vertical)
Max. speed
Max. pushing force
Positioning accuracy
Type of guide Precision cross-roller control
Operating temperature 5 to 40 °C (free of humidity)
Allowed static moment
Off-set load: 15.7 Nm; Torque: 15.7 Nm;
Lateral torque: 7.84 Nm
Brake
Model Negative maneuver type
Static torque 0.1 Nm or more
With precision cross-roller guide For horizontal or vertical mounting
Electric slide unit – horizontal
Part number Stroke Pitch
Electric slide unit – vertical with brake
Part number Stroke Pitch
Applicable drive units
Slide unit DC power supply
Allowed kinetic moment
Slide table with moment from either direction relative to
the center of gravity. Off-set load should be within limits
shown in the chart below.
Off-set load
Applicable load W (kg)
W = applicable load (kg).
L1, L2 = off-set load in relation to the center of gravity.
a = load acceleration (mm/s
2
).
Me = kinetic moment.
Applicable load W (kg) Applicable load W (kg)
Torque Lateral torque
= DELIVERY EX-STOCK FOR MORE INFO, ASK THE SMC EXPERTS: PHONE +32 (0) 3 355 1464 / INFO@SMCPNEUMATICS.BE
a
Mes
W
L1
L2
a
Meg
W
L2
W
Mer
L1 (mm)
L2 (mm)
L2 (mm)
1000
0
5 9
500
a = 1000–3000
1000
0
5 9
500
a = 1000–3000
4000
3000
2000
1000
0
5 9
a = 1000
a = 2000
a = 3000