Datasheet
7
333
■
LXFH5SA LXFH5SB
25, 50, 75, 100 mm
3 kg 2 kg
100 mm/s 200 mm/s
15 N
±0.05 mm
LXFH5SA-25S-Q 25 mm 6 mm
LXFH5SA-50S-Q 50 mm 6 mm
LXFH5SA-75S-Q 75 mm 6 mm
LXFH5SB-25S-Q 25 mm 12 mm
LXFH5SB-50S-Q 50 mm 12 mm
LXFH5SB-75S-Q 75 mm 12 mm
LXFH5SB-100S-Q 100 mm 12 mm
LED
0.5 m (–) 3 m (L)
D-F9N
✔ ✔
D-F9P
✔ ✔
D-F9B
✔ ✔
LXFH5S
LC6D-507AD
Subject to change
ELECTRIC ACTUATORS
= DELIVERY EX-STOCK FOR MORE INFO, ASK THE SMC EXPERTS: PHONE +31 (0) 20 531 88 88 / INFO@SMCPNEUMATICS.NL
LXF – compact electric slide unit
(stepper motor)
Model
Stroke
Motor 5-phase stepper motor
Screw
Ø8, pitch 6 mm Ø8, pitch 12 mm
Max. load
(horizontal direction)
Max. speed
Max. pushing force
Positioning accuracy
Type of guide Linear slide control
Operating temperature 5 to 40 °C (free of humidity)
Allowed static moment
Off-set load: 4 Nm; Torque: 3 Nm;
Lateral torque: 4 Nm
■ Space saving ■ For horizontal use ■ Integrated slide bearing
Electric slide unit – horizontal
Part number Stroke Pitch
Allowed kinetic moment
Slide table with moment from either direction relative to
the center of gravity. Off-set load should be within limits
shown in the chart below.
Applicable sensors – electronic
Designation Output
Cable ori-
entation
Cable length
3-wire/NPN Yes In-line
3-wire/PNP Yes In-line
2-wire Yes In-line
Applicable drive unit
Slide unit DC power supply
Off-set load
Applicable load W (kg)
W = applicable load (kg).
L1, L2 = off-set load in relation to the center of gravity.
a = load acceleration (mm/s
2
).
Me = kinetic moment.
Applicable load W (kg) Applicable load W (kg)
Torque Lateral torque
= DELIVERY EX-STOCK FOR MORE INFO, ASK THE SMC EXPERTS: PHONE +32 (0) 3 355 1464 / INFO@SMCPNEUMATICS.BE
0
1 2 3
5000
4000
3000
2000
1000
5000
4000
3000
2000
1000
0
1 2 3
600
500
400
300
200
100
0
1 2 3
a = 2000
a
Mes
W
L1
L2
a
Meg
W
L2
W
Mer
L1 (mm)
L2 (mm)
L2 (mm)
a = 1000
a = 2000
a = 3000
a = 1000
a = 2000
a = 3000
a = 1000
a = 3000