Datasheet

2
33
ITV0010 ITV0030 ITV0050
0.2 MPa (2 bar) 1.1 MPa (10 bar)
3.5 l
n
/min 6 l
n
/min 6 l
n
/min
ITV0010-3N-Q
ITV0030-3N-Q
ITV0050-3N-Q
ITV0010-0N-Q
ITV0030-0N-Q
ITV0050-0N-Q
WX-84SL-20
WX-84S-20
P39800022
P39800023
Subject to changes
AIR PREPARATION EQUIPMENT
= DELIVERY EX-STOCK FOR MORE INFO, ASK THE SMC EXPERTS: PHONE +31 (0) 20 531 88 88 / INFO@SMCPNEUMATICS.NL
ITV0000 E/P converter
Type
Medium Air
1
, degree of ltration min. 5 µm, oil-free air
Max. inlet pressure
Min. inlet pressure Secondary pressure +0.1 MPa
Max. ow
Operating temperature 0 to 50 °C
Connection Single unit 4 mm (ramp 6 mm and 4 mm)
Monitor signal Analog 1–5 V
Vikt 100 g or less
1. If the medium contains large amounts of water, oil aerosols or compressor oil it can cause
malfunction. Contact SMC for selecting the appropriate filter.
Fast, accurate E/P converters suitable for applications requiring
compact size and low ow rates
E/P converter single mounting
Input 0–10 V, power supply 24 VDC
Part number Secondary pressure
0.001 to 0.1 MPa
0.001 to 0.5 MPa
0.001 to 0.9 MPa
Input 4–20 mA, power supply 24 VDC
Part number Secondary pressure
0.001 to 0.1 MPa
0.001 to 0.5 MPa
0.001 to 0.9 MPa
Input 0–5 V or 0–20 mA on request.
E/P converter manifold mounting, contact SMC
Connecting cable
Part number Type
Straight
Angled
Foot bracket single unit
Part number Type
Flat
L-bracket
Manifold mounting
= DELIVERY EX-STOCK FOR MORE INFO, ASK THE SMC EXPERTS: PHONE +32 (0) 3 355 1464 / INFO@SMCPNEUMATICS.BE