Datasheet
2
23
■
5 µm
1 MPa (10 bar)
0.2 MPa (2 bar)
G1/8
1.8 W
IP65
EAV2000-F02-5YZ-Q G1/4 1168 l
n
/min
EAV3000-F03-5YZ-Q G3/8 2160 l
n
/min
EAV4000-F04-5YZ-Q G1/2 3533 l
n
/min
EAV5000-F06-5YZ-Q G3/4 6160 l
n
/min
EAV5000-F10-5YZ-Q G1 6653 l
n
/min
EAVA2000-F02 G1/4 1168 l
n
/min
EAVA3000-F03 G3/8 2160 l
n
/min
EAVA4000-F04 G1/2 3533 l
n
/min
SF4-5YZ-80-Q 24 VDC
SF4-4YZ-80-Q 220 VAC
AN20-02 30 dB R1/4
AN30-03 30 dB R3/8
AN40-04 30 dB R1/2
AN500-06 30 dB R3/4
AN600-10 30 dB R1
VP544/VP744 VP544R/VP744R
0.25–0.7 MPa (2.5–7 bar)
24 VDC
IP65
VP544-5YZ1-03F-M-X538 G3/8 1275 l
n
/min
VP544R-5YZ1-03F-M-X538 G3/8 1275 l
n
/min
VP744-5YZ1-04F-M-X538 G1/2 2258 l
n
/min
VP744R-5YZ1-04F-M-X538 G1/2 2258 l
n
/min
Subject to changes
AIR PREPARATION EQUIPMENT
= DELIVERY EX-STOCK FOR MORE INFO, ASK THE SMC EXPERTS: PHONE +31 (0) 20 531 88 88 / INFO@SMCPNEUMATICS.NL
EAV – soft start-up valve
Medium Air, lubricated or not lubricated
Degree of ltration
Max. working pressure
Min. working pressure
Operating temperature 0 to 60 °C
Pressure gauge
Voltage 24 VDC (220 VAC and others on request)
Power requirements
Electrical connection Connection DIN 43650BY (included in EAV)
Enclosure
■ Easy to connect to air preparation unit
■ Gives smaller dimensions
■ Combinations can be customized and pre-assembled
Soft start-up valve – 24 VDC, with connection
Part number Connection Flow
EAV pressurizes the system by adjustable throttle.
When the EAV reached 50% of the set pressure, it opens to full flow.
The EAV has quick exhaust in case of emergency
For 220 VAC, contact SMC.
Soft start-up valve – pneumatic
Part number Connection Flow
Pilot valve for EAV – spare part
Part number Voltage
Silencer – for exhaust port
Part number Silencing Connection
Silencer ordered separately.
VP-X538
– valve for safety-related systems
Type
Medium Air
Working pressure
Operation Internal pilot type External pilot type
Operating temperature –10 to 50 °C (no freezing/no condensation)
Voltage
Electrical connection DIN 43650C and M12 connector
Enclosure
Note! No less than 0,25 MPa external pilot pressure (as working pressure). Use external pilot type
if supply pressure may drop or is choked on start-up. Valve must be combined with a relevant
control system in order to comply with EN ISO 13849-1.
■ Easy modular connection to air preparation unit ■ Compact size ■ For control systems
in category 3 and 4 (EN ISO 13849-1) ■ Redundant valves and mechanical feedback on control inputs
Valve
Part number Connection Flow
= DELIVERY EX-STOCK FOR MORE INFO, ASK THE SMC EXPERTS: PHONE +32 (0) 3 355 1464 / INFO@SMCPNEUMATICS.BE