Datasheet

5
171
EX250-
SAS3
EX250-
SAS5
EX250-
SAS7
EX250-
SAS9
AS-Interface (AS-I) version 2.11
100 mA 65 mA 100 mA 65 mA
8 4 8 4
8 4 8 4
2 1 2 1
31
1–31
IP67
UL, CE
EX250-SAS3
EX250-SAS5
EX250-SAS7
EX250-SAS9
EX250-EA1
EX250-EA2
EXASI-5
EX250-IE1 EX250-IE2 EX250-IE3
M12 M12 M8
EX250-IE1
EX250-IE2
EX250-IE3
EX250-IE1-X103
EX250-IE2-X103
EX250-IE3-X103
EX9-FU05
WX-83P
PCA-1557743
Subject to change
FIELDBUS
= DELIVERY EX-STOCK FOR MORE INFO, ASK THE SMC EXPERTS: PHONE +31 (0) 20 531 88 88 / INFO@SMCPNEUMATICS.NL
EX250 serial interface unit (AS-Interface)
Type
Fieldbus protocol
Data + power supply
(yellow AS-I cable)
26.5–31.6 VDC from the AS-I-transmission
1
Supply voltage
valve slaves
24 VDC +10% to –5% in accordance
with PELV standard (IEC364-4-41)
External power supply
(black AS-I cable)
Yes Yes No No
Max. power consumption
(SI unit)
Inputs
Outputs
Number of busy slaves
Max. no. of connected slaves
Address assignement range
Enclosure
Standards
1. Use a power supply suitable for AS–I.
Up to 8 outputs to valves per node Up to 8 inputs per node M8 or M12
For valve series VQC, SV and SY
Serial interface unit – for AS-I
Part number Description
AS-I node 8 in/8 out (external power supply)
AS-I node 4 in/4 out (external power supply)
AS-I node 8 in/8 out
1
AS-I node 4 in/4 out
1
End plate, input side
(standard)
End plate, input side
(DIN rail mounting)
1. Use low power valves (0.5 W) for EX250-SAS7/9.
Connector for AS-I node
Part number Description
M12 (4-pin female), 1 m cable for connection
to AS-I cable
Input modules
mounted using supplied tie rods
Type
Number of inputs 2 channels 4 channels 4 channels
Input connector type
Transistor input PNP or NPN (selectable via switch)
Power supply
24 VDC (1 V voltage drop
for power supply)
Sensor type 2- or 3-wire sensors
Power supply to
sensors
120 mA per input module
Input modules
Part number Description
Input module, 2 inputs (2 × M12)
Input module, 4 inputs (2 × M12)
Input module, 4 inputs (4 × M8)
Input module, 2 inputs (2 × M12),
polarityswitch
1
Input module, 4 inputs (2 × M12),
polarityswitch
1
Input module, 4 inputs (4 × M8),
polarityswitch
1
1. Polarityswitch with protection element
SMC’s EX250 series is designed to connect the valve
series VQC, SV and SY (see chapter 4) and input mod-
ules for different eldbus protocols.
All input and output signals are combined in a
compact manifold that conforms to IP67. Up to 8 input
channels and 8 outputs can be connected in a single
manifold.
All connections (air, power supplies, eldbus and
sensor) are located on the same side of the manifold
which allows mounting in tight spaces.
All status indicators clearly visualized by LEDs on the
front of the manifold.
Installation manuals are available on SMC’s website
www.smc.eu.
For eldbus connectors and cabling,
see end of this chapter.
Fuse
for input modules
Part number Description
0.5 A fuse for EX250-IE1, -2 & -3
Connectors for input modules
Part number Description
M8 (connector), screw connection to EX250-IE3
M12 (connector), screw connection to EX250-IE1 & -2
= DELIVERY EX-STOCK FOR MORE INFO, ASK THE SMC EXPERTS: PHONE +32 (0) 3 355 1464 / INFO@SMCPNEUMATICS.BE